Groups | Search | Server Info | Keyboard shortcuts | Login | Register [http] [https] [nntp] [nntps]


Groups > sci.electronics.design > #463472

Re: 5 to 10kV rated gate transformers

From Jasen Betts <jasen@xnet.co.nz>
Newsgroups sci.electronics.design
Subject Re: 5 to 10kV rated gate transformers
Date 2017-06-07 20:03 +0000
Organization "JJ's own news server"
Message-ID <oh9m6e$pq7$1@gonzo.alcatraz> (permalink)
References (2 earlier) <309fdaf8-1982-42da-95ef-792a528f3843@googlegroups.com> <ogs14k01lfu@drn.newsguy.com> <5931d510$0$4814$426a74cc@news.free.fr> <epe47kFcg7cU2@mid.individual.net> <5932697f$0$10173$426a34cc@news.free.fr>

Show all headers | View raw


On 2017-06-03, habib <h.bouazizviallet@free.fr> wrote:
> Le 02/06/2017 à 23:39, Joerg a écrit :
>> On 2017-06-02 14:13, habib wrote:
>>> Le 02/06/2017 à 17:44, Winfield Hill a écrit :
>>>> My next step, play with potting and
>>>>   a month-long 2x overvoltage test at 10kV."
>>>>   https://www.digikey.com/products/en?keywords=ELF-21C023A
>>>>
>>>>   I'm preparing the potting fixture now
>>>>
>>>> .  That
>>>>   will make this a custom transformer.
>>>
>>> Ok. What sort of potting are you using, I remember the resin they used
>>> was a polyurethan compound (from Axson) which is quite dangerous to
>>> handle and degassing could occur during polymerization ... I've always
>>> consider those HV components suspicious.
>>>
>> 
>> Win's lab:
>> 
>> http://i.dailymail.co.uk/i/pix/2015/11/26/12/2ED34DBF00000578-0-image-a-27_1448542599816.jpg 
>> 
>> 
>> :-)
>> 
>
> The trash near the inflamed desk on which "ON" is written and the two 
> guys not so impressed ... i suspect this was not the first shot ... next 
> time it will be the building itself going to blow !
>

That looks a bit like like my high-school chemistry class, probably zinc and sulphur reacting.
the teacher knew how much to use to get the flames up to the ceiling.


-- 
This email has not been checked by half-arsed antivirus software 

Back to sci.electronics.design | Previous | Next — Previous in thread | Next in thread | Find similar | Unroll thread


Thread

5 to 10kV rated gate transformers Winfield Hill <hill@rowland.harvard.edu> - 2017-05-17 14:33 -0700
  Re: 5 to 10kV rated gate transformers John Larkin <jjlarkin@highland_snip_technology.com> - 2017-05-17 15:09 -0700
    Re: 5 to 10kV rated gate transformers Winfield Hill <hill@rowland.harvard.edu> - 2017-05-31 07:39 -0700
  Re: 5 to 10kV rated gate transformers "Tim Williams" <tiwill@seventransistorlabs.com> - 2017-05-18 01:21 -0500
    Re: 5 to 10kV rated gate transformers Winfield Hill <hill@rowland.harvard.edu> - 2017-05-31 07:30 -0700
  Re: 5 to 10kV rated gate transformers oldschool@tubes.com - 2017-05-18 08:34 -0400
    Re: 5 to 10kV rated gate transformers Winfield Hill <hill@rowland.harvard.edu> - 2017-05-18 10:07 -0700
      Re: 5 to 10kV rated gate transformers Klaus Kragelund <klauskvik@hotmail.com> - 2017-05-18 10:53 -0700
        Re: 5 to 10kV rated gate transformers speff <spehro@gmail.com> - 2017-05-18 12:59 -0700
        Re: 5 to 10kV rated gate transformers habib <h.bouazizviallet@free.fr> - 2017-05-31 22:03 +0200
          Re: 5 to 10kV rated gate transformers Lasse Langwadt Christensen <langwadt@fonz.dk> - 2017-05-31 13:22 -0700
            Re: 5 to 10kV rated gate transformers habib <h.bouazizviallet@free.fr> - 2017-05-31 23:04 +0200
              Re: 5 to 10kV rated gate transformers John Larkin <jjlarkin@highland_snip_technology.com> - 2017-05-31 15:57 -0700
                Re: 5 to 10kV rated gate transformers Jan Panteltje <pNa0nStpealmtje@yahoo.com> - 2017-06-01 07:47 +0000
                Re: 5 to 10kV rated gate transformers John Larkin <jjlarkin@highlandtechnology.com> - 2017-06-01 07:13 -0700
                Re: 5 to 10kV rated gate transformers Jan Panteltje <pNa0nStpealmtje@yahoo.com> - 2017-06-01 14:28 +0000
                Re: 5 to 10kV rated gate transformers Klaus Kragelund <klauskvik@hotmail.com> - 2017-06-01 07:42 -0700
                Re: 5 to 10kV rated gate transformers Klaus Kragelund <klauskvik@hotmail.com> - 2017-06-01 07:43 -0700
                Re: 5 to 10kV rated gate transformers John Larkin <jjlarkin@highlandtechnology.com> - 2017-06-01 08:47 -0700
                Re: 5 to 10kV rated gate transformers klaus.kragelund@gmail.com - 2017-06-02 01:25 -0700
                Re: 5 to 10kV rated gate transformers John Larkin <jjlarkin@highlandtechnology.com> - 2017-06-02 07:59 -0700
                Re: 5 to 10kV rated gate transformers Joerg <news@analogconsultants.com> - 2017-06-02 09:21 -0700
                Re: 5 to 10kV rated gate transformers John Larkin <jjlarkin@highlandtechnology.com> - 2017-06-02 09:32 -0700
                Re: 5 to 10kV rated gate transformers Joerg <news@analogconsultants.com> - 2017-06-02 10:08 -0700
                Re: 5 to 10kV rated gate transformers Jim Thompson <To-Email-Use-The-Envelope-Icon@On-My-Web-Site.com> - 2017-06-02 10:21 -0700
                Re: 5 to 10kV rated gate transformers Joerg <news@analogconsultants.com> - 2017-06-02 10:46 -0700
                Re: 5 to 10kV rated gate transformers Jan Panteltje <pNa0nStpealmtje@yahoo.com> - 2017-06-02 17:54 +0000
                Re: 5 to 10kV rated gate transformers John Larkin <jjlarkin@highland_snip_technology.com> - 2017-06-02 11:02 -0700
                Re: 5 to 10kV rated gate transformers Jim Thompson <To-Email-Use-The-Envelope-Icon@On-My-Web-Site.com> - 2017-06-02 11:05 -0700
                Re: 5 to 10kV rated gate transformers Jan Panteltje <pNa0nStpealmtje@yahoo.com> - 2017-06-02 18:16 +0000
                Re: 5 to 10kV rated gate transformers Joerg <news@analogconsultants.com> - 2017-06-02 11:32 -0700
                Re: 5 to 10kV rated gate transformers John Larkin <jjlarkin@highland_snip_technology.com> - 2017-06-02 12:15 -0700
                Re: 5 to 10kV rated gate transformers Joerg <news@analogconsultants.com> - 2017-06-02 12:43 -0700
                Re: 5 to 10kV rated gate transformers klaus.kragelund@gmail.com - 2017-06-02 10:04 -0700
                Re: 5 to 10kV rated gate transformers John Larkin <jjlarkin@highland_snip_technology.com> - 2017-06-02 10:54 -0700
                Re: 5 to 10kV rated gate transformers "Tim Williams" <tiwill@seventransistorlabs.com> - 2017-06-02 17:35 -0500
                Re: 5 to 10kV rated gate transformers John Larkin <jjlarkin@highland_snip_technology.com> - 2017-06-02 15:56 -0700
                Re: 5 to 10kV rated gate transformers upsidedown@downunder.com - 2017-06-01 17:44 +0300
                Re: 5 to 10kV rated gate transformers Jan Panteltje <pNa0nStpealmtje@yahoo.com> - 2017-06-01 14:57 +0000
                Re: 5 to 10kV rated gate transformers Winfield Hill <hill@rowland.harvard.edu> - 2017-06-01 08:05 -0700
                Re: 5 to 10kV rated gate transformers John Larkin <jjlarkin@highlandtechnology.com> - 2017-06-01 08:45 -0700
                Re: 5 to 10kV rated gate transformers Jan Panteltje <pNa0nStpealmtje@yahoo.com> - 2017-06-01 16:07 +0000
                Re: 5 to 10kV rated gate transformers John Larkin <jjlarkin@highland_snip_technology.com> - 2017-06-02 11:08 -0700
                Re: 5 to 10kV rated gate transformers Joerg <news@analogconsultants.com> - 2017-06-02 11:37 -0700
                Re: 5 to 10kV rated gate transformers Klaus Kragelund <klauskvik@hotmail.com> - 2017-06-01 07:33 -0700
                Re: 5 to 10kV rated gate transformers Jan Panteltje <pNa0nStpealmtje@yahoo.com> - 2017-06-01 14:56 +0000
        Re: 5 to 10kV rated gate transformers upsidedown@downunder.com - 2017-06-01 12:08 +0300
          Re: 5 to 10kV rated gate transformers habib.bouaziz@gmail.com - 2017-06-01 04:12 -0700
          Re: 5 to 10kV rated gate transformers John Larkin <jjlarkin@highlandtechnology.com> - 2017-06-01 07:15 -0700
      Re: 5 to 10kV rated gate transformers Jan Panteltje <pNa0nStpealmtje@yahoo.com> - 2017-05-18 20:08 +0000
      Re: 5 to 10kV rated gate transformers upsidedown@downunder.com - 2017-05-19 00:03 +0300
      Re: 5 to 10kV rated gate transformers John Larkin <jjlarkin@highland_snip_technology.com> - 2017-05-18 14:12 -0700
  Re: 5 to 10kV rated gate transformers Joerg <news@analogconsultants.com> - 2017-05-31 10:48 -0700
  Re: 5 to 10kV rated gate transformers habib <h.bouazizviallet@free.fr> - 2017-05-31 21:50 +0200
    Re: 5 to 10kV rated gate transformers Lasse Langwadt Christensen <langwadt@fonz.dk> - 2017-05-31 12:57 -0700
      Re: 5 to 10kV rated gate transformers habib <h.bouazizviallet@free.fr> - 2017-05-31 22:10 +0200
        Re: 5 to 10kV rated gate transformers Joerg <news@analogconsultants.com> - 2017-06-01 13:09 -0700
          Re: 5 to 10kV rated gate transformers habib <h.bouazizviallet@free.fr> - 2017-06-01 23:17 +0200
            Re: 5 to 10kV rated gate transformers Joerg <news@analogconsultants.com> - 2017-06-01 14:35 -0700
              Re: 5 to 10kV rated gate transformers habib.bouaziz@gmail.com - 2017-06-02 07:01 -0700
                Re: 5 to 10kV rated gate transformers Winfield Hill <hill@rowland.harvard.edu> - 2017-06-02 08:44 -0700
                Re: 5 to 10kV rated gate transformers Joerg <news@analogconsultants.com> - 2017-06-02 09:19 -0700
                Re: 5 to 10kV rated gate transformers Winfield Hill <hill@rowland.harvard.edu> - 2017-06-02 11:18 -0700
                Re: 5 to 10kV rated gate transformers John Larkin <jjlarkin@highlandtechnology.com> - 2017-06-02 09:28 -0700
                Re: 5 to 10kV rated gate transformers Joerg <news@analogconsultants.com> - 2017-06-02 09:35 -0700
                Re: 5 to 10kV rated gate transformers John Larkin <jjlarkin@highland_snip_technology.com> - 2017-06-02 11:16 -0700
                Re: 5 to 10kV rated gate transformers Winfield Hill <hill@rowland.harvard.edu> - 2017-06-02 14:02 -0700
                Re: 5 to 10kV rated gate transformers Joerg <news@analogconsultants.com> - 2017-06-02 14:36 -0700
                Re: 5 to 10kV rated gate transformers John Larkin <jjlarkin@highland_snip_technology.com> - 2017-06-02 16:08 -0700
                Re: 5 to 10kV rated gate transformers Jan Panteltje <pNa0nStpealmtje@yahoo.com> - 2017-06-02 16:46 +0000
                Re: 5 to 10kV rated gate transformers habib <h.bouazizviallet@free.fr> - 2017-06-02 23:13 +0200
                Re: 5 to 10kV rated gate transformers Joerg <news@analogconsultants.com> - 2017-06-02 14:39 -0700
                Re: 5 to 10kV rated gate transformers habib <h.bouazizviallet@free.fr> - 2017-06-03 09:47 +0200
                Re: 5 to 10kV rated gate transformers klaus.kragelund@gmail.com - 2017-06-03 04:28 -0700
                Re: 5 to 10kV rated gate transformers Jasen Betts <jasen@xnet.co.nz> - 2017-06-07 20:03 +0000
                Re: 5 to 10kV rated gate transformers Winfield Hill <hill@rowland.harvard.edu> - 2017-06-08 10:12 -0700
                Re: 5 to 10kV rated gate transformers dagmargoodboat@yahoo.com - 2017-07-13 07:35 -0700
  Re: 5 to 10kV rated gate transformers Terry <respect__privacy@hotmail.com> - 2017-06-02 06:06 -0700
    Re: 5 to 10kV rated gate transformers Joerg <news@analogconsultants.com> - 2017-06-02 09:27 -0700
  Re: 5 to 10kV rated gate transformers bloggs.fredbloggs.fred@gmail.com - 2017-07-13 07:43 -0700

csiph-web