Groups | Search | Server Info | Keyboard shortcuts | Login | Register [http] [https] [nntp] [nntps]
Groups > sci.electronics.design > #462712
| From | Joerg <news@analogconsultants.com> |
|---|---|
| Newsgroups | sci.electronics.design |
| Subject | Re: 5 to 10kV rated gate transformers |
| Date | 2017-06-02 10:46 -0700 |
| Message-ID | <epdmikF9djaU1@mid.individual.net> (permalink) |
| References | (7 earlier) <p7v2jc1u85ehj03h1o9heqi249171vhmtl@4ax.com> <epdhklF87v0U2@mid.individual.net> <mi43jchu0dab470tb8ksmn1ng084bm627u@4ax.com> <epdkb9F8su9U1@mid.individual.net> <kh73jcpe1vl0q4stcidjukl3p5lmq1r5nu@4ax.com> |
On 2017-06-02 10:21, Jim Thompson wrote: > On Fri, 02 Jun 2017 10:08:03 -0700, Joerg <news@analogconsultants.com> > wrote: > > [snip] >> >> Then there is the risk of touching. On one of my HV designs I had to be >> the first one bitten. The Chinese engineer who was with me laughed and >> said "See, you should have included a warning in German, not just >> English and Spanish". > > When I was doing ignition system designs (~1968), I got blown off of a > lab stool onto my butt... producing great laughter from the > technicians ;-) > I put a long crack into a sturdy wood cabinet door (the good stuff, custom-made by a carpenter) when flying off the chair after touching HV. -- Regards, Joerg http://www.analogconsultants.com/
Back to sci.electronics.design | Previous | Next — Previous in thread | Next in thread | Find similar | Unroll thread
5 to 10kV rated gate transformers Winfield Hill <hill@rowland.harvard.edu> - 2017-05-17 14:33 -0700
Re: 5 to 10kV rated gate transformers John Larkin <jjlarkin@highland_snip_technology.com> - 2017-05-17 15:09 -0700
Re: 5 to 10kV rated gate transformers Winfield Hill <hill@rowland.harvard.edu> - 2017-05-31 07:39 -0700
Re: 5 to 10kV rated gate transformers "Tim Williams" <tiwill@seventransistorlabs.com> - 2017-05-18 01:21 -0500
Re: 5 to 10kV rated gate transformers Winfield Hill <hill@rowland.harvard.edu> - 2017-05-31 07:30 -0700
Re: 5 to 10kV rated gate transformers oldschool@tubes.com - 2017-05-18 08:34 -0400
Re: 5 to 10kV rated gate transformers Winfield Hill <hill@rowland.harvard.edu> - 2017-05-18 10:07 -0700
Re: 5 to 10kV rated gate transformers Klaus Kragelund <klauskvik@hotmail.com> - 2017-05-18 10:53 -0700
Re: 5 to 10kV rated gate transformers speff <spehro@gmail.com> - 2017-05-18 12:59 -0700
Re: 5 to 10kV rated gate transformers habib <h.bouazizviallet@free.fr> - 2017-05-31 22:03 +0200
Re: 5 to 10kV rated gate transformers Lasse Langwadt Christensen <langwadt@fonz.dk> - 2017-05-31 13:22 -0700
Re: 5 to 10kV rated gate transformers habib <h.bouazizviallet@free.fr> - 2017-05-31 23:04 +0200
Re: 5 to 10kV rated gate transformers John Larkin <jjlarkin@highland_snip_technology.com> - 2017-05-31 15:57 -0700
Re: 5 to 10kV rated gate transformers Jan Panteltje <pNa0nStpealmtje@yahoo.com> - 2017-06-01 07:47 +0000
Re: 5 to 10kV rated gate transformers John Larkin <jjlarkin@highlandtechnology.com> - 2017-06-01 07:13 -0700
Re: 5 to 10kV rated gate transformers Jan Panteltje <pNa0nStpealmtje@yahoo.com> - 2017-06-01 14:28 +0000
Re: 5 to 10kV rated gate transformers Klaus Kragelund <klauskvik@hotmail.com> - 2017-06-01 07:42 -0700
Re: 5 to 10kV rated gate transformers Klaus Kragelund <klauskvik@hotmail.com> - 2017-06-01 07:43 -0700
Re: 5 to 10kV rated gate transformers John Larkin <jjlarkin@highlandtechnology.com> - 2017-06-01 08:47 -0700
Re: 5 to 10kV rated gate transformers klaus.kragelund@gmail.com - 2017-06-02 01:25 -0700
Re: 5 to 10kV rated gate transformers John Larkin <jjlarkin@highlandtechnology.com> - 2017-06-02 07:59 -0700
Re: 5 to 10kV rated gate transformers Joerg <news@analogconsultants.com> - 2017-06-02 09:21 -0700
Re: 5 to 10kV rated gate transformers John Larkin <jjlarkin@highlandtechnology.com> - 2017-06-02 09:32 -0700
Re: 5 to 10kV rated gate transformers Joerg <news@analogconsultants.com> - 2017-06-02 10:08 -0700
Re: 5 to 10kV rated gate transformers Jim Thompson <To-Email-Use-The-Envelope-Icon@On-My-Web-Site.com> - 2017-06-02 10:21 -0700
Re: 5 to 10kV rated gate transformers Joerg <news@analogconsultants.com> - 2017-06-02 10:46 -0700
Re: 5 to 10kV rated gate transformers Jan Panteltje <pNa0nStpealmtje@yahoo.com> - 2017-06-02 17:54 +0000
Re: 5 to 10kV rated gate transformers John Larkin <jjlarkin@highland_snip_technology.com> - 2017-06-02 11:02 -0700
Re: 5 to 10kV rated gate transformers Jim Thompson <To-Email-Use-The-Envelope-Icon@On-My-Web-Site.com> - 2017-06-02 11:05 -0700
Re: 5 to 10kV rated gate transformers Jan Panteltje <pNa0nStpealmtje@yahoo.com> - 2017-06-02 18:16 +0000
Re: 5 to 10kV rated gate transformers Joerg <news@analogconsultants.com> - 2017-06-02 11:32 -0700
Re: 5 to 10kV rated gate transformers John Larkin <jjlarkin@highland_snip_technology.com> - 2017-06-02 12:15 -0700
Re: 5 to 10kV rated gate transformers Joerg <news@analogconsultants.com> - 2017-06-02 12:43 -0700
Re: 5 to 10kV rated gate transformers klaus.kragelund@gmail.com - 2017-06-02 10:04 -0700
Re: 5 to 10kV rated gate transformers John Larkin <jjlarkin@highland_snip_technology.com> - 2017-06-02 10:54 -0700
Re: 5 to 10kV rated gate transformers "Tim Williams" <tiwill@seventransistorlabs.com> - 2017-06-02 17:35 -0500
Re: 5 to 10kV rated gate transformers John Larkin <jjlarkin@highland_snip_technology.com> - 2017-06-02 15:56 -0700
Re: 5 to 10kV rated gate transformers upsidedown@downunder.com - 2017-06-01 17:44 +0300
Re: 5 to 10kV rated gate transformers Jan Panteltje <pNa0nStpealmtje@yahoo.com> - 2017-06-01 14:57 +0000
Re: 5 to 10kV rated gate transformers Winfield Hill <hill@rowland.harvard.edu> - 2017-06-01 08:05 -0700
Re: 5 to 10kV rated gate transformers John Larkin <jjlarkin@highlandtechnology.com> - 2017-06-01 08:45 -0700
Re: 5 to 10kV rated gate transformers Jan Panteltje <pNa0nStpealmtje@yahoo.com> - 2017-06-01 16:07 +0000
Re: 5 to 10kV rated gate transformers John Larkin <jjlarkin@highland_snip_technology.com> - 2017-06-02 11:08 -0700
Re: 5 to 10kV rated gate transformers Joerg <news@analogconsultants.com> - 2017-06-02 11:37 -0700
Re: 5 to 10kV rated gate transformers Klaus Kragelund <klauskvik@hotmail.com> - 2017-06-01 07:33 -0700
Re: 5 to 10kV rated gate transformers Jan Panteltje <pNa0nStpealmtje@yahoo.com> - 2017-06-01 14:56 +0000
Re: 5 to 10kV rated gate transformers upsidedown@downunder.com - 2017-06-01 12:08 +0300
Re: 5 to 10kV rated gate transformers habib.bouaziz@gmail.com - 2017-06-01 04:12 -0700
Re: 5 to 10kV rated gate transformers John Larkin <jjlarkin@highlandtechnology.com> - 2017-06-01 07:15 -0700
Re: 5 to 10kV rated gate transformers Jan Panteltje <pNa0nStpealmtje@yahoo.com> - 2017-05-18 20:08 +0000
Re: 5 to 10kV rated gate transformers upsidedown@downunder.com - 2017-05-19 00:03 +0300
Re: 5 to 10kV rated gate transformers John Larkin <jjlarkin@highland_snip_technology.com> - 2017-05-18 14:12 -0700
Re: 5 to 10kV rated gate transformers Joerg <news@analogconsultants.com> - 2017-05-31 10:48 -0700
Re: 5 to 10kV rated gate transformers habib <h.bouazizviallet@free.fr> - 2017-05-31 21:50 +0200
Re: 5 to 10kV rated gate transformers Lasse Langwadt Christensen <langwadt@fonz.dk> - 2017-05-31 12:57 -0700
Re: 5 to 10kV rated gate transformers habib <h.bouazizviallet@free.fr> - 2017-05-31 22:10 +0200
Re: 5 to 10kV rated gate transformers Joerg <news@analogconsultants.com> - 2017-06-01 13:09 -0700
Re: 5 to 10kV rated gate transformers habib <h.bouazizviallet@free.fr> - 2017-06-01 23:17 +0200
Re: 5 to 10kV rated gate transformers Joerg <news@analogconsultants.com> - 2017-06-01 14:35 -0700
Re: 5 to 10kV rated gate transformers habib.bouaziz@gmail.com - 2017-06-02 07:01 -0700
Re: 5 to 10kV rated gate transformers Winfield Hill <hill@rowland.harvard.edu> - 2017-06-02 08:44 -0700
Re: 5 to 10kV rated gate transformers Joerg <news@analogconsultants.com> - 2017-06-02 09:19 -0700
Re: 5 to 10kV rated gate transformers Winfield Hill <hill@rowland.harvard.edu> - 2017-06-02 11:18 -0700
Re: 5 to 10kV rated gate transformers John Larkin <jjlarkin@highlandtechnology.com> - 2017-06-02 09:28 -0700
Re: 5 to 10kV rated gate transformers Joerg <news@analogconsultants.com> - 2017-06-02 09:35 -0700
Re: 5 to 10kV rated gate transformers John Larkin <jjlarkin@highland_snip_technology.com> - 2017-06-02 11:16 -0700
Re: 5 to 10kV rated gate transformers Winfield Hill <hill@rowland.harvard.edu> - 2017-06-02 14:02 -0700
Re: 5 to 10kV rated gate transformers Joerg <news@analogconsultants.com> - 2017-06-02 14:36 -0700
Re: 5 to 10kV rated gate transformers John Larkin <jjlarkin@highland_snip_technology.com> - 2017-06-02 16:08 -0700
Re: 5 to 10kV rated gate transformers Jan Panteltje <pNa0nStpealmtje@yahoo.com> - 2017-06-02 16:46 +0000
Re: 5 to 10kV rated gate transformers habib <h.bouazizviallet@free.fr> - 2017-06-02 23:13 +0200
Re: 5 to 10kV rated gate transformers Joerg <news@analogconsultants.com> - 2017-06-02 14:39 -0700
Re: 5 to 10kV rated gate transformers habib <h.bouazizviallet@free.fr> - 2017-06-03 09:47 +0200
Re: 5 to 10kV rated gate transformers klaus.kragelund@gmail.com - 2017-06-03 04:28 -0700
Re: 5 to 10kV rated gate transformers Jasen Betts <jasen@xnet.co.nz> - 2017-06-07 20:03 +0000
Re: 5 to 10kV rated gate transformers Winfield Hill <hill@rowland.harvard.edu> - 2017-06-08 10:12 -0700
Re: 5 to 10kV rated gate transformers dagmargoodboat@yahoo.com - 2017-07-13 07:35 -0700
Re: 5 to 10kV rated gate transformers Terry <respect__privacy@hotmail.com> - 2017-06-02 06:06 -0700
Re: 5 to 10kV rated gate transformers Joerg <news@analogconsultants.com> - 2017-06-02 09:27 -0700
Re: 5 to 10kV rated gate transformers bloggs.fredbloggs.fred@gmail.com - 2017-07-13 07:43 -0700
csiph-web