On a sunny day (Wed, 31 May 2017 15:57:39 -0700) it happened John Larkin
<jjlarkin@highland_snip_technology.com> wrote in
<s9iuic999l0geju4m3fcbgtdcavkosj6cq@4ax.com>:

>On Wed, 31 May 2017 23:04:21 +0200, habib <h.bouazizviallet@free.fr>
>wrote:
>
>>Le 31/05/2017 à 22:22, Lasse Langwadt Christensen a écrit :
>>> Den onsdag den 31. maj 2017 kl. 22.04.11 UTC+2 skrev habib:
>>>> Le 18/05/2017 à 19:53, Klaus Kragelund a écrit :
>>>>> Spiral turns on top and bottom layer of PCB. Prepeg can handle 10's of kV
>>>>>
>>>>> Cheers
>>>>>
>>>>> Klaus
>>>>>
>>>> Klaus,
>>>>
>>>> Are you sure PCB prepreg could sustain "10's of kV" ? I'm sure not ! My
>>>> experience of that sort of things (10 or 15KV/AC 60 or 50Hz for 1
>>>> minute) is very far from a standard ... very far from !!
>>>>
>>> 
>>> http://www.magazines007.com/pdf/High-Voltage-PCDesign.pdf ?
>>> 
>>> haven't read it
>>Klaus,
>>
>>No I have not read it yet, I will of course tomorrow morning at work. 
>>Mat be I'll learn something useful. Thx.
>>
>>Habib.
>
>He says that 800 v/mil is a typical spec for FR4, and 300 v/mil is
>conservative for long-term use. That would be 300*62 = 18.6 KV
>side-to-side on a standard 62 mil board.
>
>Sounds good to me, a free transformer, no winding required.

Surface size depends on number of turns, current, frequency,
do you need some core material?, board surface outside needs some cover
(moisture in air high relative humidity) else it is just a big capacitor to air,
would not trust it at 18 kV for a microsecond.
You would need to cover it with several mm of some isolating stuff,
not just 'solder screen'.
Yes I have read that paper, not much new we did not know.

Go optical.

Back to sci.electronics.design | Previous | Next — Previous in thread | Next in thread | Find similar | Unroll thread


Thread

5 to 10kV rated gate transformers Winfield Hill <hill@rowland.harvard.edu> - 2017-05-17 14:33 -0700
  Re: 5 to 10kV rated gate transformers John Larkin <jjlarkin@highland_snip_technology.com> - 2017-05-17 15:09 -0700
    Re: 5 to 10kV rated gate transformers Winfield Hill <hill@rowland.harvard.edu> - 2017-05-31 07:39 -0700
  Re: 5 to 10kV rated gate transformers "Tim Williams" <tiwill@seventransistorlabs.com> - 2017-05-18 01:21 -0500
    Re: 5 to 10kV rated gate transformers Winfield Hill <hill@rowland.harvard.edu> - 2017-05-31 07:30 -0700
  Re: 5 to 10kV rated gate transformers oldschool@tubes.com - 2017-05-18 08:34 -0400
    Re: 5 to 10kV rated gate transformers Winfield Hill <hill@rowland.harvard.edu> - 2017-05-18 10:07 -0700
      Re: 5 to 10kV rated gate transformers Klaus Kragelund <klauskvik@hotmail.com> - 2017-05-18 10:53 -0700
        Re: 5 to 10kV rated gate transformers speff <spehro@gmail.com> - 2017-05-18 12:59 -0700
        Re: 5 to 10kV rated gate transformers habib <h.bouazizviallet@free.fr> - 2017-05-31 22:03 +0200
          Re: 5 to 10kV rated gate transformers Lasse Langwadt Christensen <langwadt@fonz.dk> - 2017-05-31 13:22 -0700
            Re: 5 to 10kV rated gate transformers habib <h.bouazizviallet@free.fr> - 2017-05-31 23:04 +0200
              Re: 5 to 10kV rated gate transformers John Larkin <jjlarkin@highland_snip_technology.com> - 2017-05-31 15:57 -0700
                Re: 5 to 10kV rated gate transformers Jan Panteltje <pNa0nStpealmtje@yahoo.com> - 2017-06-01 07:47 +0000
                Re: 5 to 10kV rated gate transformers John Larkin <jjlarkin@highlandtechnology.com> - 2017-06-01 07:13 -0700
                Re: 5 to 10kV rated gate transformers Jan Panteltje <pNa0nStpealmtje@yahoo.com> - 2017-06-01 14:28 +0000
                Re: 5 to 10kV rated gate transformers Klaus Kragelund <klauskvik@hotmail.com> - 2017-06-01 07:42 -0700
                Re: 5 to 10kV rated gate transformers Klaus Kragelund <klauskvik@hotmail.com> - 2017-06-01 07:43 -0700
                Re: 5 to 10kV rated gate transformers John Larkin <jjlarkin@highlandtechnology.com> - 2017-06-01 08:47 -0700
                Re: 5 to 10kV rated gate transformers klaus.kragelund@gmail.com - 2017-06-02 01:25 -0700
                Re: 5 to 10kV rated gate transformers John Larkin <jjlarkin@highlandtechnology.com> - 2017-06-02 07:59 -0700
                Re: 5 to 10kV rated gate transformers Joerg <news@analogconsultants.com> - 2017-06-02 09:21 -0700
                Re: 5 to 10kV rated gate transformers John Larkin <jjlarkin@highlandtechnology.com> - 2017-06-02 09:32 -0700
                Re: 5 to 10kV rated gate transformers Joerg <news@analogconsultants.com> - 2017-06-02 10:08 -0700
                Re: 5 to 10kV rated gate transformers Jim Thompson <To-Email-Use-The-Envelope-Icon@On-My-Web-Site.com> - 2017-06-02 10:21 -0700
                Re: 5 to 10kV rated gate transformers Joerg <news@analogconsultants.com> - 2017-06-02 10:46 -0700
                Re: 5 to 10kV rated gate transformers Jan Panteltje <pNa0nStpealmtje@yahoo.com> - 2017-06-02 17:54 +0000
                Re: 5 to 10kV rated gate transformers John Larkin <jjlarkin@highland_snip_technology.com> - 2017-06-02 11:02 -0700
                Re: 5 to 10kV rated gate transformers Jim Thompson <To-Email-Use-The-Envelope-Icon@On-My-Web-Site.com> - 2017-06-02 11:05 -0700
                Re: 5 to 10kV rated gate transformers Jan Panteltje <pNa0nStpealmtje@yahoo.com> - 2017-06-02 18:16 +0000
                Re: 5 to 10kV rated gate transformers Joerg <news@analogconsultants.com> - 2017-06-02 11:32 -0700
                Re: 5 to 10kV rated gate transformers John Larkin <jjlarkin@highland_snip_technology.com> - 2017-06-02 12:15 -0700
                Re: 5 to 10kV rated gate transformers Joerg <news@analogconsultants.com> - 2017-06-02 12:43 -0700
                Re: 5 to 10kV rated gate transformers klaus.kragelund@gmail.com - 2017-06-02 10:04 -0700
                Re: 5 to 10kV rated gate transformers John Larkin <jjlarkin@highland_snip_technology.com> - 2017-06-02 10:54 -0700
                Re: 5 to 10kV rated gate transformers "Tim Williams" <tiwill@seventransistorlabs.com> - 2017-06-02 17:35 -0500
                Re: 5 to 10kV rated gate transformers John Larkin <jjlarkin@highland_snip_technology.com> - 2017-06-02 15:56 -0700
                Re: 5 to 10kV rated gate transformers upsidedown@downunder.com - 2017-06-01 17:44 +0300
                Re: 5 to 10kV rated gate transformers Jan Panteltje <pNa0nStpealmtje@yahoo.com> - 2017-06-01 14:57 +0000
                Re: 5 to 10kV rated gate transformers Winfield Hill <hill@rowland.harvard.edu> - 2017-06-01 08:05 -0700
                Re: 5 to 10kV rated gate transformers John Larkin <jjlarkin@highlandtechnology.com> - 2017-06-01 08:45 -0700
                Re: 5 to 10kV rated gate transformers Jan Panteltje <pNa0nStpealmtje@yahoo.com> - 2017-06-01 16:07 +0000
                Re: 5 to 10kV rated gate transformers John Larkin <jjlarkin@highland_snip_technology.com> - 2017-06-02 11:08 -0700
                Re: 5 to 10kV rated gate transformers Joerg <news@analogconsultants.com> - 2017-06-02 11:37 -0700
                Re: 5 to 10kV rated gate transformers Klaus Kragelund <klauskvik@hotmail.com> - 2017-06-01 07:33 -0700
                Re: 5 to 10kV rated gate transformers Jan Panteltje <pNa0nStpealmtje@yahoo.com> - 2017-06-01 14:56 +0000
        Re: 5 to 10kV rated gate transformers upsidedown@downunder.com - 2017-06-01 12:08 +0300
          Re: 5 to 10kV rated gate transformers habib.bouaziz@gmail.com - 2017-06-01 04:12 -0700
          Re: 5 to 10kV rated gate transformers John Larkin <jjlarkin@highlandtechnology.com> - 2017-06-01 07:15 -0700
      Re: 5 to 10kV rated gate transformers Jan Panteltje <pNa0nStpealmtje@yahoo.com> - 2017-05-18 20:08 +0000
      Re: 5 to 10kV rated gate transformers upsidedown@downunder.com - 2017-05-19 00:03 +0300
      Re: 5 to 10kV rated gate transformers John Larkin <jjlarkin@highland_snip_technology.com> - 2017-05-18 14:12 -0700
  Re: 5 to 10kV rated gate transformers Joerg <news@analogconsultants.com> - 2017-05-31 10:48 -0700
  Re: 5 to 10kV rated gate transformers habib <h.bouazizviallet@free.fr> - 2017-05-31 21:50 +0200
    Re: 5 to 10kV rated gate transformers Lasse Langwadt Christensen <langwadt@fonz.dk> - 2017-05-31 12:57 -0700
      Re: 5 to 10kV rated gate transformers habib <h.bouazizviallet@free.fr> - 2017-05-31 22:10 +0200
        Re: 5 to 10kV rated gate transformers Joerg <news@analogconsultants.com> - 2017-06-01 13:09 -0700
          Re: 5 to 10kV rated gate transformers habib <h.bouazizviallet@free.fr> - 2017-06-01 23:17 +0200
            Re: 5 to 10kV rated gate transformers Joerg <news@analogconsultants.com> - 2017-06-01 14:35 -0700
              Re: 5 to 10kV rated gate transformers habib.bouaziz@gmail.com - 2017-06-02 07:01 -0700
                Re: 5 to 10kV rated gate transformers Winfield Hill <hill@rowland.harvard.edu> - 2017-06-02 08:44 -0700
                Re: 5 to 10kV rated gate transformers Joerg <news@analogconsultants.com> - 2017-06-02 09:19 -0700
                Re: 5 to 10kV rated gate transformers Winfield Hill <hill@rowland.harvard.edu> - 2017-06-02 11:18 -0700
                Re: 5 to 10kV rated gate transformers John Larkin <jjlarkin@highlandtechnology.com> - 2017-06-02 09:28 -0700
                Re: 5 to 10kV rated gate transformers Joerg <news@analogconsultants.com> - 2017-06-02 09:35 -0700
                Re: 5 to 10kV rated gate transformers John Larkin <jjlarkin@highland_snip_technology.com> - 2017-06-02 11:16 -0700
                Re: 5 to 10kV rated gate transformers Winfield Hill <hill@rowland.harvard.edu> - 2017-06-02 14:02 -0700
                Re: 5 to 10kV rated gate transformers Joerg <news@analogconsultants.com> - 2017-06-02 14:36 -0700
                Re: 5 to 10kV rated gate transformers John Larkin <jjlarkin@highland_snip_technology.com> - 2017-06-02 16:08 -0700
                Re: 5 to 10kV rated gate transformers Jan Panteltje <pNa0nStpealmtje@yahoo.com> - 2017-06-02 16:46 +0000
                Re: 5 to 10kV rated gate transformers habib <h.bouazizviallet@free.fr> - 2017-06-02 23:13 +0200
                Re: 5 to 10kV rated gate transformers Joerg <news@analogconsultants.com> - 2017-06-02 14:39 -0700
                Re: 5 to 10kV rated gate transformers habib <h.bouazizviallet@free.fr> - 2017-06-03 09:47 +0200
                Re: 5 to 10kV rated gate transformers klaus.kragelund@gmail.com - 2017-06-03 04:28 -0700
                Re: 5 to 10kV rated gate transformers Jasen Betts <jasen@xnet.co.nz> - 2017-06-07 20:03 +0000
                Re: 5 to 10kV rated gate transformers Winfield Hill <hill@rowland.harvard.edu> - 2017-06-08 10:12 -0700
                Re: 5 to 10kV rated gate transformers dagmargoodboat@yahoo.com - 2017-07-13 07:35 -0700
  Re: 5 to 10kV rated gate transformers Terry <respect__privacy@hotmail.com> - 2017-06-02 06:06 -0700
    Re: 5 to 10kV rated gate transformers Joerg <news@analogconsultants.com> - 2017-06-02 09:27 -0700
  Re: 5 to 10kV rated gate transformers bloggs.fredbloggs.fred@gmail.com - 2017-07-13 07:43 -0700

csiph-web