Groups | Search | Server Info | Keyboard shortcuts | Login | Register [http] [https] [nntp] [nntps]


Groups > sci.electronics.design > #462689

Re: 5 to 10kV rated gate transformers

From Joerg <news@analogconsultants.com>
Newsgroups sci.electronics.design
Subject Re: 5 to 10kV rated gate transformers
Date 2017-06-02 09:35 -0700
Message-ID <epdif1F8fbdU1@mid.individual.net> (permalink)
References <ofifji02a2d@drn.newsguy.com> <592f1e94$0$8852$426a74cc@news.free.fr> <309fdaf8-1982-42da-95ef-792a528f3843@googlegroups.com> <ogs14k01lfu@drn.newsguy.com> <vu33jc96ih5mq6u4188uj6cu3hfhvdbdhq@4ax.com>

Show all headers | View raw


On 2017-06-02 09:28, John Larkin wrote:
> On 2 Jun 2017 08:44:20 -0700, Winfield Hill <hill@rowland.harvard.edu>
> wrote:

[...]


>> I'm preparing the potting fixture now.  That
>> will make this a custom transformer. :-)  The
>> Panasonic transformer looks well suited, with
>> thick bobbin insulating plastic, and generous
>> room for further insulation through potting.
>> Only need to handle 2.5kV to the ferrite core.
>>
>> Another parameter, the coil-coil capacitance
>> is under 2pF.  Amazing, I had budgeted to 10pF.
>
> Potting is a sticky, ugly mess. You need to measure, mix, degass,
> pour, wait, clean up.
>
> I like the idea of drum cores or pot cores on opposite sides of a PCB,
> but nobody else seems interested. Imagine just a couple of cheap
> pick-and-place inductors doing the job.
>

AFAIK you can't buy an open half pot core as a standard part. I'd be all 
ears if you could.

Upright unshielded rod inductors, yes, but their spew around EMI to no 
end. They are like a dirt bike with the muffler sawed off.

-- 
Regards, Joerg

http://www.analogconsultants.com/

Back to sci.electronics.design | Previous | Next — Previous in thread | Next in thread | Find similar | Unroll thread


Thread

5 to 10kV rated gate transformers Winfield Hill <hill@rowland.harvard.edu> - 2017-05-17 14:33 -0700
  Re: 5 to 10kV rated gate transformers John Larkin <jjlarkin@highland_snip_technology.com> - 2017-05-17 15:09 -0700
    Re: 5 to 10kV rated gate transformers Winfield Hill <hill@rowland.harvard.edu> - 2017-05-31 07:39 -0700
  Re: 5 to 10kV rated gate transformers "Tim Williams" <tiwill@seventransistorlabs.com> - 2017-05-18 01:21 -0500
    Re: 5 to 10kV rated gate transformers Winfield Hill <hill@rowland.harvard.edu> - 2017-05-31 07:30 -0700
  Re: 5 to 10kV rated gate transformers oldschool@tubes.com - 2017-05-18 08:34 -0400
    Re: 5 to 10kV rated gate transformers Winfield Hill <hill@rowland.harvard.edu> - 2017-05-18 10:07 -0700
      Re: 5 to 10kV rated gate transformers Klaus Kragelund <klauskvik@hotmail.com> - 2017-05-18 10:53 -0700
        Re: 5 to 10kV rated gate transformers speff <spehro@gmail.com> - 2017-05-18 12:59 -0700
        Re: 5 to 10kV rated gate transformers habib <h.bouazizviallet@free.fr> - 2017-05-31 22:03 +0200
          Re: 5 to 10kV rated gate transformers Lasse Langwadt Christensen <langwadt@fonz.dk> - 2017-05-31 13:22 -0700
            Re: 5 to 10kV rated gate transformers habib <h.bouazizviallet@free.fr> - 2017-05-31 23:04 +0200
              Re: 5 to 10kV rated gate transformers John Larkin <jjlarkin@highland_snip_technology.com> - 2017-05-31 15:57 -0700
                Re: 5 to 10kV rated gate transformers Jan Panteltje <pNa0nStpealmtje@yahoo.com> - 2017-06-01 07:47 +0000
                Re: 5 to 10kV rated gate transformers John Larkin <jjlarkin@highlandtechnology.com> - 2017-06-01 07:13 -0700
                Re: 5 to 10kV rated gate transformers Jan Panteltje <pNa0nStpealmtje@yahoo.com> - 2017-06-01 14:28 +0000
                Re: 5 to 10kV rated gate transformers Klaus Kragelund <klauskvik@hotmail.com> - 2017-06-01 07:42 -0700
                Re: 5 to 10kV rated gate transformers Klaus Kragelund <klauskvik@hotmail.com> - 2017-06-01 07:43 -0700
                Re: 5 to 10kV rated gate transformers John Larkin <jjlarkin@highlandtechnology.com> - 2017-06-01 08:47 -0700
                Re: 5 to 10kV rated gate transformers klaus.kragelund@gmail.com - 2017-06-02 01:25 -0700
                Re: 5 to 10kV rated gate transformers John Larkin <jjlarkin@highlandtechnology.com> - 2017-06-02 07:59 -0700
                Re: 5 to 10kV rated gate transformers Joerg <news@analogconsultants.com> - 2017-06-02 09:21 -0700
                Re: 5 to 10kV rated gate transformers John Larkin <jjlarkin@highlandtechnology.com> - 2017-06-02 09:32 -0700
                Re: 5 to 10kV rated gate transformers Joerg <news@analogconsultants.com> - 2017-06-02 10:08 -0700
                Re: 5 to 10kV rated gate transformers Jim Thompson <To-Email-Use-The-Envelope-Icon@On-My-Web-Site.com> - 2017-06-02 10:21 -0700
                Re: 5 to 10kV rated gate transformers Joerg <news@analogconsultants.com> - 2017-06-02 10:46 -0700
                Re: 5 to 10kV rated gate transformers Jan Panteltje <pNa0nStpealmtje@yahoo.com> - 2017-06-02 17:54 +0000
                Re: 5 to 10kV rated gate transformers John Larkin <jjlarkin@highland_snip_technology.com> - 2017-06-02 11:02 -0700
                Re: 5 to 10kV rated gate transformers Jim Thompson <To-Email-Use-The-Envelope-Icon@On-My-Web-Site.com> - 2017-06-02 11:05 -0700
                Re: 5 to 10kV rated gate transformers Jan Panteltje <pNa0nStpealmtje@yahoo.com> - 2017-06-02 18:16 +0000
                Re: 5 to 10kV rated gate transformers Joerg <news@analogconsultants.com> - 2017-06-02 11:32 -0700
                Re: 5 to 10kV rated gate transformers John Larkin <jjlarkin@highland_snip_technology.com> - 2017-06-02 12:15 -0700
                Re: 5 to 10kV rated gate transformers Joerg <news@analogconsultants.com> - 2017-06-02 12:43 -0700
                Re: 5 to 10kV rated gate transformers klaus.kragelund@gmail.com - 2017-06-02 10:04 -0700
                Re: 5 to 10kV rated gate transformers John Larkin <jjlarkin@highland_snip_technology.com> - 2017-06-02 10:54 -0700
                Re: 5 to 10kV rated gate transformers "Tim Williams" <tiwill@seventransistorlabs.com> - 2017-06-02 17:35 -0500
                Re: 5 to 10kV rated gate transformers John Larkin <jjlarkin@highland_snip_technology.com> - 2017-06-02 15:56 -0700
                Re: 5 to 10kV rated gate transformers upsidedown@downunder.com - 2017-06-01 17:44 +0300
                Re: 5 to 10kV rated gate transformers Jan Panteltje <pNa0nStpealmtje@yahoo.com> - 2017-06-01 14:57 +0000
                Re: 5 to 10kV rated gate transformers Winfield Hill <hill@rowland.harvard.edu> - 2017-06-01 08:05 -0700
                Re: 5 to 10kV rated gate transformers John Larkin <jjlarkin@highlandtechnology.com> - 2017-06-01 08:45 -0700
                Re: 5 to 10kV rated gate transformers Jan Panteltje <pNa0nStpealmtje@yahoo.com> - 2017-06-01 16:07 +0000
                Re: 5 to 10kV rated gate transformers John Larkin <jjlarkin@highland_snip_technology.com> - 2017-06-02 11:08 -0700
                Re: 5 to 10kV rated gate transformers Joerg <news@analogconsultants.com> - 2017-06-02 11:37 -0700
                Re: 5 to 10kV rated gate transformers Klaus Kragelund <klauskvik@hotmail.com> - 2017-06-01 07:33 -0700
                Re: 5 to 10kV rated gate transformers Jan Panteltje <pNa0nStpealmtje@yahoo.com> - 2017-06-01 14:56 +0000
        Re: 5 to 10kV rated gate transformers upsidedown@downunder.com - 2017-06-01 12:08 +0300
          Re: 5 to 10kV rated gate transformers habib.bouaziz@gmail.com - 2017-06-01 04:12 -0700
          Re: 5 to 10kV rated gate transformers John Larkin <jjlarkin@highlandtechnology.com> - 2017-06-01 07:15 -0700
      Re: 5 to 10kV rated gate transformers Jan Panteltje <pNa0nStpealmtje@yahoo.com> - 2017-05-18 20:08 +0000
      Re: 5 to 10kV rated gate transformers upsidedown@downunder.com - 2017-05-19 00:03 +0300
      Re: 5 to 10kV rated gate transformers John Larkin <jjlarkin@highland_snip_technology.com> - 2017-05-18 14:12 -0700
  Re: 5 to 10kV rated gate transformers Joerg <news@analogconsultants.com> - 2017-05-31 10:48 -0700
  Re: 5 to 10kV rated gate transformers habib <h.bouazizviallet@free.fr> - 2017-05-31 21:50 +0200
    Re: 5 to 10kV rated gate transformers Lasse Langwadt Christensen <langwadt@fonz.dk> - 2017-05-31 12:57 -0700
      Re: 5 to 10kV rated gate transformers habib <h.bouazizviallet@free.fr> - 2017-05-31 22:10 +0200
        Re: 5 to 10kV rated gate transformers Joerg <news@analogconsultants.com> - 2017-06-01 13:09 -0700
          Re: 5 to 10kV rated gate transformers habib <h.bouazizviallet@free.fr> - 2017-06-01 23:17 +0200
            Re: 5 to 10kV rated gate transformers Joerg <news@analogconsultants.com> - 2017-06-01 14:35 -0700
              Re: 5 to 10kV rated gate transformers habib.bouaziz@gmail.com - 2017-06-02 07:01 -0700
                Re: 5 to 10kV rated gate transformers Winfield Hill <hill@rowland.harvard.edu> - 2017-06-02 08:44 -0700
                Re: 5 to 10kV rated gate transformers Joerg <news@analogconsultants.com> - 2017-06-02 09:19 -0700
                Re: 5 to 10kV rated gate transformers Winfield Hill <hill@rowland.harvard.edu> - 2017-06-02 11:18 -0700
                Re: 5 to 10kV rated gate transformers John Larkin <jjlarkin@highlandtechnology.com> - 2017-06-02 09:28 -0700
                Re: 5 to 10kV rated gate transformers Joerg <news@analogconsultants.com> - 2017-06-02 09:35 -0700
                Re: 5 to 10kV rated gate transformers John Larkin <jjlarkin@highland_snip_technology.com> - 2017-06-02 11:16 -0700
                Re: 5 to 10kV rated gate transformers Winfield Hill <hill@rowland.harvard.edu> - 2017-06-02 14:02 -0700
                Re: 5 to 10kV rated gate transformers Joerg <news@analogconsultants.com> - 2017-06-02 14:36 -0700
                Re: 5 to 10kV rated gate transformers John Larkin <jjlarkin@highland_snip_technology.com> - 2017-06-02 16:08 -0700
                Re: 5 to 10kV rated gate transformers Jan Panteltje <pNa0nStpealmtje@yahoo.com> - 2017-06-02 16:46 +0000
                Re: 5 to 10kV rated gate transformers habib <h.bouazizviallet@free.fr> - 2017-06-02 23:13 +0200
                Re: 5 to 10kV rated gate transformers Joerg <news@analogconsultants.com> - 2017-06-02 14:39 -0700
                Re: 5 to 10kV rated gate transformers habib <h.bouazizviallet@free.fr> - 2017-06-03 09:47 +0200
                Re: 5 to 10kV rated gate transformers klaus.kragelund@gmail.com - 2017-06-03 04:28 -0700
                Re: 5 to 10kV rated gate transformers Jasen Betts <jasen@xnet.co.nz> - 2017-06-07 20:03 +0000
                Re: 5 to 10kV rated gate transformers Winfield Hill <hill@rowland.harvard.edu> - 2017-06-08 10:12 -0700
                Re: 5 to 10kV rated gate transformers dagmargoodboat@yahoo.com - 2017-07-13 07:35 -0700
  Re: 5 to 10kV rated gate transformers Terry <respect__privacy@hotmail.com> - 2017-06-02 06:06 -0700
    Re: 5 to 10kV rated gate transformers Joerg <news@analogconsultants.com> - 2017-06-02 09:27 -0700
  Re: 5 to 10kV rated gate transformers bloggs.fredbloggs.fred@gmail.com - 2017-07-13 07:43 -0700

csiph-web