On 18-04-17, 17:01, Sudeep Holla wrote: > Understood. I would incline towards reusing regulators we that's what is It can be just a regulator, but it can be anything else as well. That entity may have its own clock/volt/current tunables, etc. > changed behind the scene. Calling this operating performance point > is misleading and doesn't align well with existing specs/features. Yeah, but there are no voltage levels available here and that doesn't fit as a regulator then. > Understood. We have exactly same thing with SCPI but it controls both > frequency and voltage referred as operating points. In general, this OPP > terminology is used in SCPI/ACPI/SCMI specifications as both frequency > and voltage control. I am bit worried that this binding might introduce > confusions on the definitions. But it can be reworded/renamed easily if > required. Yeah, so far we have been looking at OPPs as freq-voltage pairs ONLY and that is changing. I am not sure if it going in the wrong direction really. Without frequency also it is an operating point for the domain. Isn't it? -- viresh
Back to linux.kernel | Previous | Next — Previous in thread | Next in thread | Find similar | Unroll thread
Re: [PATCH V4 1/9] PM / OPP: Allow OPP table to be used for power-domains Sudeep Holla <sudeep.holla@arm.com> - 2017-04-12 19:00 +0200
Re: [PATCH V4 1/9] PM / OPP: Allow OPP table to be used for power-domains Viresh Kumar <viresh.kumar@linaro.org> - 2017-04-13 07:40 +0200
Re: [PATCH V4 1/9] PM / OPP: Allow OPP table to be used for power-domains Sudeep Holla <sudeep.holla@arm.com> - 2017-04-13 15:50 +0200
Re: [PATCH V4 1/9] PM / OPP: Allow OPP table to be used for power-domains Viresh Kumar <viresh.kumar@linaro.org> - 2017-04-17 07:30 +0200
Re: [PATCH V4 1/9] PM / OPP: Allow OPP table to be used for power-domains Sudeep Holla <sudeep.holla@arm.com> - 2017-04-18 18:10 +0200
Re: [PATCH V4 1/9] PM / OPP: Allow OPP table to be used for power-domains Viresh Kumar <viresh.kumar@linaro.org> - 2017-04-19 12:20 +0200
Re: [PATCH V4 1/9] PM / OPP: Allow OPP table to be used for power-domains Viresh Kumar <viresh.kumar@linaro.org> - 2017-04-19 13:50 +0200
Re: [PATCH V4 1/9] PM / OPP: Allow OPP table to be used for power-domains Sudeep Holla <sudeep.holla@arm.com> - 2017-04-19 16:00 +0200
Re: [PATCH V4 1/9] PM / OPP: Allow OPP table to be used for power-domains Viresh Kumar <viresh.kumar@linaro.org> - 2017-04-20 07:30 +0200
Re: [PATCH V4 1/9] PM / OPP: Allow OPP table to be used for power-domains Ulf Hansson <ulf.hansson@linaro.org> - 2017-04-20 10:30 +0200
Re: [PATCH V4 1/9] PM / OPP: Allow OPP table to be used for power-domains Viresh Kumar <viresh.kumar@linaro.org> - 2017-04-20 11:40 +0200
Re: [PATCH V4 1/9] PM / OPP: Allow OPP table to be used for power-domains Sudeep Holla <sudeep.holla@arm.com> - 2017-04-20 12:00 +0200
Re: [PATCH V4 1/9] PM / OPP: Allow OPP table to be used for power-domains Sudeep Holla <sudeep.holla@arm.com> - 2017-04-20 11:50 +0200
Re: [PATCH V4 1/9] PM / OPP: Allow OPP table to be used for power-domains Viresh Kumar <viresh.kumar@linaro.org> - 2017-04-20 12:00 +0200
Re: [PATCH V4 1/9] PM / OPP: Allow OPP table to be used for power-domains Kevin Hilman <khilman@baylibre.com> - 2017-04-24 21:10 +0200
csiph-web