10 mega-watt hours Winfield Hill <hill@rowland.harvard.edu> - 2016-10-07 11:16 -0700
Re: 10 mega-watt hours Jon Elson <jmelson@wustl.edu> - 2016-10-07 14:13 -0500
Re: 10 mega-watt hours Jim Thompson <To-Email-Use-The-Envelope-Icon@On-My-Web-Site.com> - 2016-10-07 12:41 -0700
Re: 10 mega-watt hours makolber@yahoo.com - 2016-10-07 13:08 -0700
Re: 10 mega-watt hours Winfield Hill <hill@rowland.harvard.edu> - 2016-10-07 14:27 -0700
Re: 10 mega-watt hours Winfield Hill <hill@rowland.harvard.edu> - 2016-10-07 14:09 -0700
Re: 10 mega-watt hours Jim Thompson <To-Email-Use-The-Envelope-Icon@On-My-Web-Site.com> - 2016-10-07 14:18 -0700
Re: 10 mega-watt hours Ralph Barone <ralph@invalid.com> - 2016-10-07 22:40 +0000
Re: 10 mega-watt hours Winfield Hill <hill@rowland.harvard.edu> - 2016-10-07 16:42 -0700
Re: 10 mega-watt hours Jim Thompson <To-Email-Use-The-Envelope-Icon@On-My-Web-Site.com> - 2016-10-07 17:35 -0700
Re: 10 mega-watt hours Jeff Liebermann <jeffl@cruzio.com> - 2016-10-08 09:09 -0700
Re: 10 mega-watt hours John Larkin <jjlarkin@highlandtechnology.com> - 2016-10-08 09:53 -0700
Re: 10 mega-watt hours Jeff Liebermann <jeffl@cruzio.com> - 2016-10-08 11:10 -0700
Re: 10 mega-watt hours Bob Engelhardt <BobEngelhardt@comcast.net> - 2016-10-09 12:30 -0400
Re: 10 mega-watt hours Jeff Liebermann <jeffl@cruzio.com> - 2016-10-09 10:26 -0700
Re: 10 mega-watt hours Ralph Barone <ralph@invalid.com> - 2016-10-08 23:38 +0000
Re: 10 mega-watt hours Jeff Liebermann <jeffl@cruzio.com> - 2016-10-08 18:13 -0700
Re: 10 mega-watt hours Ralph Barone <ralph@invalid.com> - 2016-10-09 05:02 +0000
Re: 10 mega-watt hours Jeff Liebermann <jeffl@cruzio.com> - 2016-10-08 23:29 -0700
Re: 10 mega-watt hours Chris Jones <lugnut808@spam.yahoo.com> - 2016-10-09 11:42 +1100
Re: 10 mega-watt hours Martin Riddle <martin_ridd@verizon.net> - 2016-10-07 17:30 -0400
Re: 10 mega-watt hours Winfield Hill <hill@rowland.harvard.edu> - 2016-10-07 17:14 -0700
Re: 10 mega-watt hours Jon Elson <elson@pico-systems.com> - 2016-10-11 10:28 -0500
heatpump vs furnace Winfield Hill <hill@rowland.harvard.edu> - 2016-10-12 05:57 -0700
Re: heatpump vs furnace bill.sloman@ieee.org - 2016-10-12 07:33 -0700
Re: heatpump vs furnace "dcaster@krl.org" <dcaster@krl.org> - 2016-10-12 17:41 -0700
Re: heatpump vs furnace bill.sloman@ieee.org - 2016-10-12 18:26 -0700
Re: heatpump vs furnace "dcaster@krl.org" <dcaster@krl.org> - 2016-10-13 06:45 -0700
Re: heatpump vs furnace Winfield Hill <hill@rowland.harvard.edu> - 2016-10-12 18:57 -0700
Re: heatpump vs furnace bill.sloman@ieee.org - 2016-10-12 22:36 -0700
Re: heatpump vs furnace Winfield Hill <hill@rowland.harvard.edu> - 2016-10-13 03:57 -0700
Re: heatpump vs furnace Ecnerwal <MyNameForward@ReplaceWithMyVices.Com.invalid> - 2016-10-12 10:33 -0400
Re: heatpump vs furnace Winfield Hill <hill@rowland.harvard.edu> - 2016-10-12 09:46 -0700
Re: heatpump vs furnace Ecnerwal <MyNameForward@ReplaceWithMyVices.Com.invalid> - 2016-10-12 14:39 -0400
Re: heatpump vs furnace Jim Thompson <To-Email-Use-The-Envelope-Icon@On-My-Web-Site.com> - 2016-10-12 08:10 -0700
Re: heatpump vs furnace Winfield Hill <hill@rowland.harvard.edu> - 2016-10-12 09:39 -0700
Re: heatpump vs furnace makolber@yahoo.com - 2016-10-12 13:02 -0700
Re: heatpump vs furnace Winfield Hill <hill@rowland.harvard.edu> - 2016-10-13 06:10 -0700
Re: heatpump vs furnace "David Eather" <eather@tpg.com.au> - 2016-10-15 14:47 +1000
Re: heatpump vs furnace krw <krw@nowhere.com> - 2016-10-15 10:56 -0400
Re: heatpump vs furnace "David Eather" <eather@tpg.com.au> - 2016-10-17 12:47 +1000
Re: heatpump vs furnace krw <krw@nowhere.com> - 2016-10-17 19:50 -0400
Re: 10 mega-watt hours sean.c4s.vn@gmail.com - 2016-10-12 06:13 -0700
Re: 10 mega-watt hours Yzordderrex <powersupplyguy@netzero.net> - 2016-10-13 07:52 -0700
Re: 10 mega-watt hours Winfield Hill <hill@rowland.harvard.edu> - 2016-10-13 08:09 -0700
Re: 10 mega-watt hours Yzordderrex <powersupplyguy@netzero.net> - 2016-10-14 03:05 -0700
Re: 10 mega-watt hours Winfield Hill <hill@rowland.harvard.edu> - 2016-10-14 05:52 -0700
Page 2 of 3 — ← Prev page 1 [2] 3 Next page →
| From | Martin Riddle <martin_ridd@verizon.net> |
|---|---|
| Date | 2016-10-07 17:30 -0400 |
| Message-ID | <pn4gvbhdutngkknagei0ubi8lek3umc7v7@4ax.com> |
| In reply to | #430567 |
On 7 Oct 2016 11:16:22 -0700, Winfield Hill <hill@rowland.harvard.edu> wrote: > The production meter for our solar roof just > ticked over past 10MWh. That's a pretty > serious amount of power to generate in the > 9.5 months since switching on the system. > https://enlighten.enphaseenergy.com/pv/public_systems/WAJT773668/overview Do your power credits roll over to the next year? (anniversery date) I think your allowed to change it once. And most recomend to place it in April/May, so the winter bills can be offset. You may find that your Jan/Feb bill are 'high' Cheers
[toc] | [prev] | [next] | [standalone]
| From | Winfield Hill <hill@rowland.harvard.edu> |
|---|---|
| Date | 2016-10-07 17:14 -0700 |
| Message-ID | <nt9dpt07qb@drn.newsguy.com> |
| In reply to | #430593 |
Martin Riddle wrote...
>
> Do your power credits roll over to the next year? (anniversery date)
> I think your allowed to change it once. And most recomend to place it
> in April/May, so the winter bills can be offset.
> You may find that your Jan/Feb bill are 'high'
I don't know for sure, but my understanding is the
credits do not expire. However, if we make more
than we consume, we don't get paid for any excess.
But we can give it to someone else in our district.
Like maybe our town's Senior Citizens Center.
--
Thanks,
- Win
[toc] | [prev] | [next] | [standalone]
| From | Jon Elson <elson@pico-systems.com> |
|---|---|
| Date | 2016-10-11 10:28 -0500 |
| Message-ID | <q7mdnVGeSbycmGDKnZ2dnUU7-T2dnZ2d@giganews.com> |
| In reply to | #430611 |
Winfield Hill wrote: > Martin Riddle wrote... >> >> Do your power credits roll over to the next year? (anniversery date) >> I think your allowed to change it once. And most recomend to place it >> in April/May, so the winter bills can be offset. >> You may find that your Jan/Feb bill are 'high' > > I don't know for sure, but my understanding is the > credits do not expire. However, if we make more > than we consume, we don't get paid for any excess. > But we can give it to someone else in our district. > Like maybe our town's Senior Citizens Center. > > WOW! They ALLOW you to give the utility energy for free! What an incredibly generous deal! Jon
[toc] | [prev] | [next] | [standalone]
| From | Winfield Hill <hill@rowland.harvard.edu> |
|---|---|
| Date | 2016-10-12 05:57 -0700 |
| Subject | heatpump vs furnace |
| Message-ID | <ntlc010ihl@drn.newsguy.com> |
| In reply to | #430873 |
Jon Elson wrote...
> Winfield Hill wrote:
>> Martin Riddle wrote...
>>>
>>> Do your power credits roll over to the next year? (anniversery date)
>>> I think your allowed to change it once. And most recomend to place it
>>> in April/May, so the winter bills can be offset.
>>> You may find that your Jan/Feb bill are 'high'
>>
>> I don't know for sure, but my understanding is the
>> credits do not expire. However, if we make more
>> than we consume, we don't get paid for any excess.
>> But we can give it to someone else in our district.
>> Like maybe our town's Senior Citizens Center.
>>
> WOW! They ALLOW you to give the utility energy for
> free! What an incredibly generous deal!
We just replaced our entire HVAC-oil-furnace stack,
and elected the heat-pump option instead of a simple
AC compressor. I've been taking some performance
measurements, e.g. with Tout = 45 deg, it takes the
heatpump about 1 hour to raise the house temp by 2
degrees. It consumes 5kW, so that's 2.5kWh/deg.
Whoa, we'll be using far more electricity than our
roof makes! The default outside-temp breakpoint
for switching to the oil burner is 40 degrees.
I'm studying the thermostat manual's installation
instructions to change to 50 degrees. They claim
heatpump heating is cheaper than oil, but I doubt
it! Anybody have experience with a hybrid system?
--
Thanks,
- Win
[toc] | [prev] | [next] | [standalone]
| From | bill.sloman@ieee.org |
|---|---|
| Date | 2016-10-12 07:33 -0700 |
| Subject | Re: heatpump vs furnace |
| Message-ID | <a13ab296-9aa4-4852-b0e3-df43b7c7d99c@googlegroups.com> |
| In reply to | #430979 |
On Wednesday, October 12, 2016 at 11:57:54 PM UTC+11, Winfield Hill wrote: > Jon Elson wrote... > > Winfield Hill wrote: > >> Martin Riddle wrote... > >>> > >>> Do your power credits roll over to the next year? (anniversary date) > >>> I think your allowed to change it once. And most recomend to place it > >>> in April/May, so the winter bills can be offset. > >>> You may find that your Jan/Feb bill are 'high' > >> > >> I don't know for sure, but my understanding is the > >> credits do not expire. However, if we make more > >> than we consume, we don't get paid for any excess. > >> But we can give it to someone else in our district. > >> Like maybe our town's Senior Citizens Center. > >> > > WOW! They ALLOW you to give the utility energy for > > free! What an incredibly generous deal! > > We just replaced our entire HVAC-oil-furnace stack, > and elected the heat-pump option instead of a simple > AC compressor. I've been taking some performance > measurements, e.g. with Tout = 45 deg, it takes the > heatpump about 1 hour to raise the house temp by 2 > degrees. It consumes 5kW, so that's 2.5kWh/deg. > Whoa, we'll be using far more electricity than our > roof makes! The default outside-temp breakpoint > for switching to the oil burner is 40 degrees. > I'm studying the thermostat manual's installation > instructions to change to 50 degrees. They claim > heatpump heating is cheaper than oil, but I doubt > it! Heat-pump heating is cheaper than oil per kilowatt-hour delivered if the temperature difference between the inside of the house and the external radiator is small enough. The real advantage obviously is that the heat pump can go both ways - to cool the house in summer and to heat the house in winter. In Sydney it's a good deal. In the UK you needed a bigger heat pump to supply the heat you needed in the depths of winter, and the capital cost got a bit out of hand. I never did the sums myself, but I knew people who did. If you could super-insulate your house to start with, the heat pump made more sense - the 150 Watt you generate all the time (alright 100 Watt when resting, about 150 Watt when doing stuff and anything up to 600 Watt when doing hard physical labour) started being a significant part of the heat you needed in the depths of winter. Using a buried heat-exchanger coil also made sense - about 50cm of dirt is about six months of thermal lag, so some of the heat you pumped into the ground in summer could still be hanging around in winter when you needed to pump it back out - but it's even more capital investment. -- Bill Sloman, Sydney
[toc] | [prev] | [next] | [standalone]
| From | "dcaster@krl.org" <dcaster@krl.org> |
|---|---|
| Date | 2016-10-12 17:41 -0700 |
| Subject | Re: heatpump vs furnace |
| Message-ID | <1f485c34-1286-425a-90dd-76c9812cfb48@googlegroups.com> |
| In reply to | #430985 |
On Wednesday, October 12, 2016 at 10:33:10 AM UTC-4, bill....@ieee.org wrote:
>
> Using a buried heat-exchanger coil also made sense - about 50cm of dirt is about six months of thermal lag, so some of the heat you pumped into the ground in summer could still be hanging around in winter when you needed to pump it back out - but it's even more capital investment.
>
> --
> Bill Sloman, Sydney
All of the data I have seen on soil temperatures does not agree with your statement of 50 cm giving a six months thermal lag.
Dan
[toc] | [prev] | [next] | [standalone]
| From | bill.sloman@ieee.org |
|---|---|
| Date | 2016-10-12 18:26 -0700 |
| Subject | Re: heatpump vs furnace |
| Message-ID | <c5b822f1-f7a5-4b54-aa71-0210b7756570@googlegroups.com> |
| In reply to | #431054 |
On Thursday, October 13, 2016 at 11:41:33 AM UTC+11, dca...@krl.org wrote: > On Wednesday, October 12, 2016 at 10:33:10 AM UTC-4, bill....@ieee.org wrote: > > > > > Using a buried heat-exchanger coil also made sense - about 50cm of dirt is about six months of thermal lag, so some of the heat you pumped into the ground in summer could still be hanging around in winter when you needed to pump it back out - but it's even more capital investment. > > All of the data I have seen on soil temperatures does not agree with your statement of 50 cm giving a six months thermal lag. So post some of it. My figure is dredged out of memory. If you've got a better reference it wouldn't have to be all that good to be pretty convincing. The more general point - that a buried heat-exchanger is a good idea - still stands. It's economic viability usually does seem to depend on somebody wanting to do a lot of earth-moving anyway. -- Bill Sloman, Sydney
[toc] | [prev] | [next] | [standalone]
| From | "dcaster@krl.org" <dcaster@krl.org> |
|---|---|
| Date | 2016-10-13 06:45 -0700 |
| Subject | Re: heatpump vs furnace |
| Message-ID | <ddc62e91-2bc8-403a-b113-99aac542f155@googlegroups.com> |
| In reply to | #431063 |
On Wednesday, October 12, 2016 at 9:26:22 PM UTC-4, bill....@ieee.org wrote: > So post some of it. My figure is dredged out of memory. If you've got a better reference it wouldn't have to be all that good to be pretty convincing. > > The more general point - that a buried heat-exchanger is a good idea - still stands. It's economic viability usually does seem to depend on somebody wanting to do a lot of earth-moving anyway. > > -- > Bill Sloman, Sydney I looked at a bunch of sites before I started insulating the basement walls. But have not kept any links to the data. So if you are interested you can find the information as easily as I can. A buried heat exchanger is a good idea. But when they are used for heat pumps they generally either use a couple of wells or trenches at least 4 feet ( 1.2 meters ) deep.
[toc] | [prev] | [next] | [standalone]
| From | Winfield Hill <hill@rowland.harvard.edu> |
|---|---|
| Date | 2016-10-12 18:57 -0700 |
| Subject | Re: heatpump vs furnace |
| Message-ID | <ntmplj0go5@drn.newsguy.com> |
| In reply to | #431054 |
dcaster@krl.org wrote...
> Bill Sloman wrote
>> Using a buried heat-exchanger coil also made sense - about 50cm
>> of dirt is about six months of thermal lag, so some of the heat
>> you pumped into the ground in summer could still be hanging
>> around in winter when you needed to pump it back out - but
>> it's even more capital investment.
>
> All of the data I have seen on soil temperatures does not agree
> with your statement of 50 cm giving a six months thermal lag.
Right, it's entirely a matter of the available water.
Maybe a small well, tapping an underground aquifer.
Slightly complicated if you don't have a well.
--
Thanks,
- Win
[toc] | [prev] | [next] | [standalone]
| From | bill.sloman@ieee.org |
|---|---|
| Date | 2016-10-12 22:36 -0700 |
| Subject | Re: heatpump vs furnace |
| Message-ID | <e5d05e99-7a68-482c-b5e8-cde2c53694da@googlegroups.com> |
| In reply to | #431066 |
On Thursday, October 13, 2016 at 12:57:25 PM UTC+11, Winfield Hill wrote: > dcaster@krl.org wrote... > > Bill Sloman wrote > >> Using a buried heat-exchanger coil also made sense - about 50cm > >> of dirt is about six months of thermal lag, so some of the heat > >> you pumped into the ground in summer could still be hanging > >> around in winter when you needed to pump it back out - but > >> it's even more capital investment. > > > > All of the data I have seen on soil temperatures does not agree > > with your statement of 50 cm giving a six months thermal lag. > > Right, it's entirely a matter of the available water. > Maybe a small well, tapping an underground aquifer. > Slightly complicated if you don't have a well. It isn't. You just bury a long enough loop pf closed pipe and circulate your water - other heat exchange fluid - through it. You need to be in contact with a much larger thermal mass than the heat capacity of your house. -- Bill Sloman, Sydney
[toc] | [prev] | [next] | [standalone]
| From | Winfield Hill <hill@rowland.harvard.edu> |
|---|---|
| Date | 2016-10-13 03:57 -0700 |
| Subject | Re: heatpump vs furnace |
| Message-ID | <ntnpaj02ave@drn.newsguy.com> |
| In reply to | #431079 |
bill.sloman@ieee.org wrote...
> Winfield Hill wrote:
>> dcaster@krl.org wrote...
>>> Bill Sloman wrote
>>>> Using a buried heat-exchanger coil also made sense - about 50cm
>>>> of dirt is about six months of thermal lag, so some of the heat
>>>> you pumped into the ground in summer could still be hanging
>>>> around in winter when you needed to pump it back out - but
>>>> it's even more capital investment.
>>>
>>> All of the data I have seen on soil temperatures does not agree
>>> with your statement of 50 cm giving a six months thermal lag.
>>
>> Right, it's entirely a matter of the available water.
>> Maybe a small well, tapping an underground aquifer.
>> Slightly complicated if you don't have a well.
>
> It isn't. You just bury a long enough loop pf closed pipe
> and circulate your water - other heat exchange fluid -
> through it. You need to be in contact with a much larger
> thermal mass than the heat capacity of your house.
Exactly, and for the time period in question. Here the
ground can freeze down nearly a foot in winter. We get
a situation where the ground below that is devoid of
much water. That's a problem that has cost us several
valuable trees, because we didn't water them midwinter!
I could solve that problem by running the pipe 100 feet
down to a stream that runs through our back yard, and
burying it deep there. Maybe get a 45-degree return
fluid temperature in winter. The pipe would have to
be insulated and buried the whole way, difficult with
our yard's granite rock fill. A geothermal heat sink
would be good for more efficient AC in summer. Might
need our town's Conservation Commission permission.
I've been thinking about it. Guy who installed our
system has a geothermal hot-water heater, using an
existing well on his lot. Research geothermal heat
pumps. Probably just too many issues to overcome.
--
Thanks,
- Win
[toc] | [prev] | [next] | [standalone]
| From | Ecnerwal <MyNameForward@ReplaceWithMyVices.Com.invalid> |
|---|---|
| Date | 2016-10-12 10:33 -0400 |
| Subject | Re: heatpump vs furnace |
| Message-ID | <MyNameForward-754569.10330312102016@88-209-239-213.giganet.hu> |
| In reply to | #430979 |
In article <ntlc010ihl@drn.newsguy.com>, Winfield Hill <hill@rowland.harvard.edu> wrote: > instructions to change to 50 degrees. They claim > heatpump heating is cheaper than oil, but I doubt > it! Anybody have experience with a hybrid system? That depends very much on the specifics of the heat pump (COP) and the price of the two fuels, and the efficiency of the oil burner. In many cases it's true, particularly with a proper cold-climate heat pump (which a 40 F switchover - does not sound like.) The good cold-climate mini-splits will put out 3X the heat (COP of 3 or more) as the electricity put into them, and operate effectively down to sub-zero F temperatures. For whatever reason most whole house systems are still sucky southern-oriented things with lousy COP and poor cold performance. It's been an included line on the Vermont Fuel Price Report for a couple of years now with some assumptions you can read about and prices that may vary from your own local prices. The VFPR is one of the clearer expositions of these trade-offs on the net - If Mass. makes anything like it they hide it well, but I bet they simply don't. -- Cats, coffee, chocolate...vices to live by Please don't feed the trolls. Killfile and ignore them so they will go away.
[toc] | [prev] | [next] | [standalone]
| From | Winfield Hill <hill@rowland.harvard.edu> |
|---|---|
| Date | 2016-10-12 09:46 -0700 |
| Subject | Re: heatpump vs furnace |
| Message-ID | <ntlpd0017fm@drn.newsguy.com> |
| In reply to | #430986 |
Ecnerwal wrote...
>
>In article <ntlc010ihl@drn.newsguy.com>,
> Winfield Hill <hill@rowland.harvard.edu> wrote:
>
>> instructions to change to 50 degrees. They claim
>> heatpump heating is cheaper than oil, but I doubt
>> it! Anybody have experience with a hybrid system?
>
> That depends very much on the specifics of the heat pump
> (COP) and the price of the two fuels, and the efficiency
> of the oil burner. In many cases it's true, particularly
> with a proper cold-climate heat pump (which a 40 F
> switchover - does not sound like.)
>
> The good cold-climate mini-splits will put out 3X the heat
> (COP of 3 or more) as the electricity put into them, and
> operate effectively down to sub-zero F temperatures.
Whoa, 3x! Is that at high outside temps? Apparently
my system will work fine to far below freezing (runs
at 40-degrees with a modest duty cycle), even includes
automatic defrost features. Maybe the default 40-degree
setting is considered an economic tradeoff point. Our
installer says the electric heat-pump is cheaper down
to 40 degrees; clearly I need to research the numbers.
--
Thanks,
- Win
[toc] | [prev] | [next] | [standalone]
| From | Ecnerwal <MyNameForward@ReplaceWithMyVices.Com.invalid> |
|---|---|
| Date | 2016-10-12 14:39 -0400 |
| Subject | Re: heatpump vs furnace |
| Message-ID | <MyNameForward-46A839.14392012102016@88-209-239-213.giganet.hu> |
| In reply to | #431014 |
In article <ntlpd0017fm@drn.newsguy.com>, Winfield Hill <hill@rowland.harvard.edu> wrote: > Whoa, 3x! Is that at high outside temps? Apparently > my system will work fine to far below freezing (runs > at 40-degrees with a modest duty cycle), even includes > automatic defrost features. Maybe the default 40-degree > setting is considered an economic tradeoff point. Our > installer says the electric heat-pump is cheaper down > to 40 degrees; clearly I need to research the numbers. It varies with the specific unit and the specific temperature. If you look at the October, 2015 VFPR they discuss it vaguely and have a vague diagram with an unlabeled temperature axis to go with their guesstimate of 2.4 (240%) for Vermont conditions (which of, course, are rather variable from one end of the state to the other, plus they are trying to get an average seasonal number.) Your conditions in Eastern MA may be somewhat more favorable. COPs around 3.5 at moderate (40's F) temperatures are not uncommon. At current Vermont prices and the 2.4 COP guesstimate, oil has a slight edge per the September, 2016 report. Having see twice the price on oil and pretty much the same price on electricity in the past few years, that is not a static situation, and it's also not static with outside temperature since the COP varies with that. Ideally, you find a specific diagram (or table) that's specifically labelled for your particular unit, and then you can plug in price of electricity, price of oil (cost of what you have in the tank or replacement cost, as you prefer) and temperature to see which is cheaper, when. When oil is cheap and electricity isn't, that will be different than when oil is expensive and electricity still is kinda expensive. If you expect the election-year low-price-oil to last, history may have an opposing view. If you really want to be an efficient whacko, get a diesel generator and put your heating oil through that, recover the high quality waste heat directly, use the electricity generated to run your heat pump, and put the otherwise unrecoverable waste heat into the path of the heat pump's outside unit ;-) But then you'll have to pay sales tax on your heating oil...and it's a good deal of capital expense. Having just done the replacement, your only economically sensible option is to try and get the data on what you got, and then figure out where the tradeoff temperature is as prices shift. -- Cats, coffee, chocolate...vices to live by Please don't feed the trolls. Killfile and ignore them so they will go away.
[toc] | [prev] | [next] | [standalone]
| From | Jim Thompson <To-Email-Use-The-Envelope-Icon@On-My-Web-Site.com> |
|---|---|
| Date | 2016-10-12 08:10 -0700 |
| Subject | Re: heatpump vs furnace |
| Message-ID | <3jksvb5d3au2m1fmf7sc0u7jrroocgeqlt@4ax.com> |
| In reply to | #430979 |
On 12 Oct 2016 05:57:37 -0700, Winfield Hill
<hill@rowland.harvard.edu> wrote:
>Jon Elson wrote...
>> Winfield Hill wrote:
>>> Martin Riddle wrote...
>>>>
>>>> Do your power credits roll over to the next year? (anniversery date)
>>>> I think your allowed to change it once. And most recomend to place it
>>>> in April/May, so the winter bills can be offset.
>>>> You may find that your Jan/Feb bill are 'high'
>>>
>>> I don't know for sure, but my understanding is the
>>> credits do not expire. However, if we make more
>>> than we consume, we don't get paid for any excess.
>>> But we can give it to someone else in our district.
>>> Like maybe our town's Senior Citizens Center.
>>>
>> WOW! They ALLOW you to give the utility energy for
>> free! What an incredibly generous deal!
>
> We just replaced our entire HVAC-oil-furnace stack,
> and elected the heat-pump option instead of a simple
> AC compressor. I've been taking some performance
> measurements, e.g. with Tout = 45 deg, it takes the
> heatpump about 1 hour to raise the house temp by 2
> degrees. It consumes 5kW, so that's 2.5kWh/deg.
> Whoa, we'll be using far more electricity than our
> roof makes! The default outside-temp breakpoint
> for switching to the oil burner is 40 degrees.
> I'm studying the thermostat manual's installation
> instructions to change to 50 degrees. They claim
> heatpump heating is cheaper than oil, but I doubt
> it! Anybody have experience with a hybrid system?
But it's green >:-}
...Jim Thompson
--
| James E.Thompson | mens |
| Analog Innovations | et |
| Analog/Mixed-Signal ASIC's and Discrete Systems | manus |
| STV, Queen Creek, AZ 85142 Skype: skypeanalog | |
| Voice:(480)460-2350 Fax: Available upon request | Brass Rat |
| E-mail Icon at http://www.analog-innovations.com | 1962 |
In Memoriam...
James Ralph Thompson
October 12, 1918 - November 7, 2008
[toc] | [prev] | [next] | [standalone]
| From | Winfield Hill <hill@rowland.harvard.edu> |
|---|---|
| Date | 2016-10-12 09:39 -0700 |
| Subject | Re: heatpump vs furnace |
| Message-ID | <ntlp0h016p8@drn.newsguy.com> |
| In reply to | #430996 |
Jim Thompson wrote...
>
>> instructions to change to 50 degrees. They claim
>> heatpump heating is cheaper than oil, but I doubt
>> it! Anybody have experience with a hybrid system?
>
> But it's green >:-}
Gotta be a patriot and burn somma that Montana crude.
--
Thanks,
- Win
[toc] | [prev] | [next] | [standalone]
| From | makolber@yahoo.com |
|---|---|
| Date | 2016-10-12 13:02 -0700 |
| Subject | Re: heatpump vs furnace |
| Message-ID | <7942cded-2356-4781-b01a-894d7459b962@googlegroups.com> |
| In reply to | #430979 |
They claim > heatpump heating is cheaper than oil, but I doubt > it! Anybody have experience with a hybrid system? > > > -- > Thanks, > - Win Yes, I have a hybrid oil heat pump system. My COP is about 3 and that makes oil at $2.00 per gallon equivalent to about $0.18 per kWh of electricity. So it depends on what YOU pay for each fuel. And then there are those pesky intangible issues. What is the wear and tear cost on an AC compressor vs an oil burner? How comfortable is your house when the vent is blowing 80 deg air from the heat pump vs 120 deg air from the the oil burner? And the heat pump compressor includes a crankcase heater that runs 100 Watts 24/7 to keep it warm so it can start anytime. Freon will migrate to the coldest part of a system when it is off and you don't want your compressor full of liquid Freon when it starts, so they keep a heater running in it 24/7. And below about 32 the outside coils can freeze up and the system has to run in reverse defrost mode for a few minutes. My bottom line is, once the temp is consistently below about 35, I turn off the heat pump, switch off its breaker to kill the heater, and keep it from coming on, and I stick with the oil. I just hope oil stays around $2 per gallon. In spring I turn the breaker back on a few days before I let it run so it warms enough to drive the liquid Freon out before I let it start. mark
[toc] | [prev] | [next] | [standalone]
| From | Winfield Hill <hill@rowland.harvard.edu> |
|---|---|
| Date | 2016-10-13 06:10 -0700 |
| Subject | Re: heatpump vs furnace |
| Message-ID | <nto13n02nng@drn.newsguy.com> |
| In reply to | #431031 |
makolber@yahoo.com wrote...
>
> They claim
>> heatpump heating is cheaper than oil, but I doubt
>> it! Anybody have experience with a hybrid system?
>
> Yes, I have a hybrid oil heat pump system.
> My COP is about 3 and that makes oil at $2.00 per gallon
> equivalent to about $0.18 per kWh of electricity.
> So it depends on what YOU pay for each fuel.
My Carrier 25HCC5 heatpump's COP is 3.88 with
47 deg (+8C) air, dropping to 2.64 with cold
17-deg (-8C) air. For 40 to 50-deg settings,
and our $0.20 elec, isn't that close to a wash?
> And the heat pump compressor includes a crankcase
> heater that runs 100 Watts 24/7 to keep it warm so
> it can start anytime. Freon will migrate to the
> coldest part of a system when it is off and you
> don't want your compressor full of liquid Freon
> when it starts, so they keep a heater running in it 24/7.
Whoa! 100 watts 24-7 = $175/yr. (Sadly I have
2 to 3 times that already in wallworts, etc.)
> My bottom line is, once the temp is consistently
> below about 35, I turn off the heat pump, switch
> off its breaker to kill the heater, and keep it
> from coming on, and I stick with the oil. I just
> hope oil stays around $2 per gallon.
>
> In spring I turn the breaker back on a few days
> before I let it run so it warms enough to drive
> the liquid Freon out before I let it start.
> And below about 32 the outside coils can freeze up and the
> system has to run in reverse defrost mode for a few minutes.
Yes, we have that aspect.
--
Thanks,
- Win
[toc] | [prev] | [next] | [standalone]
| From | "David Eather" <eather@tpg.com.au> |
|---|---|
| Date | 2016-10-15 14:47 +1000 |
| Subject | Re: heatpump vs furnace |
| Message-ID | <op.ypcx9pwpwei6gd@phenom-pc> |
| In reply to | #430979 |
On Wed, 12 Oct 2016 22:57:37 +1000, Winfield Hill <hill@rowland.harvard.edu> wrote: > Jon Elson wrote... >> Winfield Hill wrote: >>> Martin Riddle wrote... >>>> >>>> Do your power credits roll over to the next year? (anniversery date) >>>> I think your allowed to change it once. And most recomend to place it >>>> in April/May, so the winter bills can be offset. >>>> You may find that your Jan/Feb bill are 'high' >>> >>> I don't know for sure, but my understanding is the >>> credits do not expire. However, if we make more >>> than we consume, we don't get paid for any excess. >>> But we can give it to someone else in our district. >>> Like maybe our town's Senior Citizens Center. >>> >> WOW! They ALLOW you to give the utility energy for >> free! What an incredibly generous deal! > > We just replaced our entire HVAC-oil-furnace stack, > and elected the heat-pump option instead of a simple > AC compressor. I've been taking some performance > measurements, e.g. with Tout = 45 deg, it takes the > heatpump about 1 hour to raise the house temp by 2 > degrees. It consumes 5kW, so that's 2.5kWh/deg. > Whoa, we'll be using far more electricity than our > roof makes! The default outside-temp breakpoint > for switching to the oil burner is 40 degrees. > I'm studying the thermostat manual's installation > instructions to change to 50 degrees. They claim > heatpump heating is cheaper than oil, but I doubt > it! Anybody have experience with a hybrid system? > > don't worry too much - the waste energy turn into heat too
[toc] | [prev] | [next] | [standalone]
| From | krw <krw@nowhere.com> |
|---|---|
| Date | 2016-10-15 10:56 -0400 |
| Subject | Re: heatpump vs furnace |
| Message-ID | <pqg40chamt4g5ct4um6lvid3le2euqk5h8@4ax.com> |
| In reply to | #431267 |
On Sat, 15 Oct 2016 14:47:39 +1000, "David Eather" <eather@tpg.com.au> wrote: >On Wed, 12 Oct 2016 22:57:37 +1000, Winfield Hill ><hill@rowland.harvard.edu> wrote: > >> Jon Elson wrote... >>> Winfield Hill wrote: >>>> Martin Riddle wrote... >>>>> >>>>> Do your power credits roll over to the next year? (anniversery date) >>>>> I think your allowed to change it once. And most recomend to place it >>>>> in April/May, so the winter bills can be offset. >>>>> You may find that your Jan/Feb bill are 'high' >>>> >>>> I don't know for sure, but my understanding is the >>>> credits do not expire. However, if we make more >>>> than we consume, we don't get paid for any excess. >>>> But we can give it to someone else in our district. >>>> Like maybe our town's Senior Citizens Center. >>>> >>> WOW! They ALLOW you to give the utility energy for >>> free! What an incredibly generous deal! >> >> We just replaced our entire HVAC-oil-furnace stack, >> and elected the heat-pump option instead of a simple >> AC compressor. I've been taking some performance >> measurements, e.g. with Tout = 45 deg, it takes the >> heatpump about 1 hour to raise the house temp by 2 >> degrees. It consumes 5kW, so that's 2.5kWh/deg. >> Whoa, we'll be using far more electricity than our >> roof makes! The default outside-temp breakpoint >> for switching to the oil burner is 40 degrees. >> I'm studying the thermostat manual's installation >> instructions to change to 50 degrees. They claim >> heatpump heating is cheaper than oil, but I doubt >> it! Anybody have experience with a hybrid system? >> >> > >don't worry too much - the waste energy turn into heat too If your intention it to heat the great outdoors.