Groups | Search | Server Info | Keyboard shortcuts | Login | Register [http] [https] [nntp] [nntps]


Groups > linux.kernel > #1160199 > unrolled thread

Re: [PATCH v2] power: max17042_battery: add HEALTH and TEMP_* properties support

Started byKrzysztof Kozlowski <k.kozlowski@samsung.com>
First post2015-06-08 03:30 +0200
Last post2015-06-23 03:00 +0200
Articles 2 — 1 participant

Back to article view | Back to linux.kernel

This discussion starts older than the indexed window; earlier articles aren't shown. The article labeled Started by below is the oldest one visible, not the original post.


Contents

  Re: [PATCH v2] power: max17042_battery: add HEALTH and TEMP_*  properties support Krzysztof Kozlowski <k.kozlowski@samsung.com> - 2015-06-08 03:30 +0200
    Re: [PATCH v2] power: max17042_battery: add HEALTH and TEMP_*  properties support Krzysztof Kozlowski <k.kozlowski@samsung.com> - 2015-06-23 03:00 +0200

#1160199 — Re: [PATCH v2] power: max17042_battery: add HEALTH and TEMP_* properties support

FromKrzysztof Kozlowski <k.kozlowski@samsung.com>
Date2015-06-08 03:30 +0200
SubjectRe: [PATCH v2] power: max17042_battery: add HEALTH and TEMP_* properties support
Message-ID<pyU2Z-8s1-3@gated-at.bofh.it>
2015-05-24 12:41 GMT+09:00 Ramakrishna Pallala <ramakrishna.pallala@intel.com>:
> This patch adds the support for following battery properties
> to max17042 fuel gauge driver.
>
> POWER_SUPPLY_PROP_TEMP_ALERT_MIN
> POWER_SUPPLY_PROP_TEMP_ALERT_MAX
> POWER_SUPPLY_PROP_TEMP_MIN
> POWER_SUPPLY_PROP_TEMP_MAX
> POWER_SUPPLY_PROP_HEALTH

I wonder, have you tested the patch? After booting on Trats2 device
(max77693 which identifies itself as 17047-like) the values are:
POWER_SUPPLY_TEMP_ALERT_MIN=1280
POWER_SUPPLY_TEMP_ALERT_MAX=1270
POWER_SUPPLY_TEMP=257
This is okay, datasheet says that register after booting will have
value of 0x7f80.

However setting them to some value which should trigger interrupts
(like 300 for MIN or 200 for MAX) does not trigger the interrupt. I
added a printk in max17042_thread_handler().

Is the temperature alert feature working?

Best regards,
Krzysztof
--
To unsubscribe from this list: send the line "unsubscribe linux-kernel" in
the body of a message to majordomo@vger.kernel.org
More majordomo info at  http://vger.kernel.org/majordomo-info.html
Please read the FAQ at  http://www.tux.org/lkml/

[toc] | [next] | [standalone]


#1170324

FromKrzysztof Kozlowski <k.kozlowski@samsung.com>
Date2015-06-23 03:00 +0200
Message-ID<pEkJc-3Dy-21@gated-at.bofh.it>
In reply to#1160199
2015-06-08 10:22 GMT+09:00 Krzysztof Kozlowski <k.kozlowski@samsung.com>:
> 2015-05-24 12:41 GMT+09:00 Ramakrishna Pallala <ramakrishna.pallala@intel.com>:
>> This patch adds the support for following battery properties
>> to max17042 fuel gauge driver.
>>
>> POWER_SUPPLY_PROP_TEMP_ALERT_MIN
>> POWER_SUPPLY_PROP_TEMP_ALERT_MAX
>> POWER_SUPPLY_PROP_TEMP_MIN
>> POWER_SUPPLY_PROP_TEMP_MAX
>> POWER_SUPPLY_PROP_HEALTH
>
> I wonder, have you tested the patch? After booting on Trats2 device
> (max77693 which identifies itself as 17047-like) the values are:
> POWER_SUPPLY_TEMP_ALERT_MIN=1280
> POWER_SUPPLY_TEMP_ALERT_MAX=1270
> POWER_SUPPLY_TEMP=257
> This is okay, datasheet says that register after booting will have
> value of 0x7f80.
>
> However setting them to some value which should trigger interrupts
> (like 300 for MIN or 200 for MAX) does not trigger the interrupt. I
> added a printk in max17042_thread_handler().
>
> Is the temperature alert feature working?

Dear Ramakrishna Pallala,

Can you reply to my question above?
If this feature is not working, then it should be removed.

Best regards,
Krzysztof
--
To unsubscribe from this list: send the line "unsubscribe linux-kernel" in
Please read the FAQ at  http://www.tux.org/lkml/

[toc] | [prev] | [standalone]


Back to top | Article view | linux.kernel