On Monday 14 September 2015 03:00 PM, Ulf Hansson wrote:
> [...]
>
>>>>>
>>>>> Could this be implemented by regulator API? From patch set 3/3, the
>>>>> pxa1928
>>>>> voltage_switch hook is to operate the IO pad registers, this seems not
>>>>> belong
>>>>> to the SDHC IP core.
>>>>>
>>>>
>>>> Not quite sure whether regulator would be right fit for this.
>>>
>>>
>>>   From the patche[3/3], this can be achieved by abstracting the IO PAD as
>>> regulators
>>> then, we may not need to touch the core sdhci.c. But I'm not sure whether
>>> this
>>> is the good solution or not.
>>
>>
>> Exactly...
>>
>>> sdhci Maintainers and experts may have better
>>> suggestions.
>>>
>>
>> Thats is the reason I stamped it as a RFC :)
>>
>
> [...]
>
>  From an mmc core perspective it would be preferred if you implement
> this as a regulator (vqmmc).
>
> Especially since we will soon have an API for how to set the I/O
> voltages - and the intelligence within that API is not something we
> would like to implement for each and every host driver.
> https://lkml.org/lkml/2015/8/31/367
>


I would still consider this as a regulator specific and may not address
the IO configuration within the SoC which are module specific.
The API regulator_set_voltage_triplet() will not have intelligence to
differentiate whether the call is coming from MMC or somewhere else.

Note that, the IO pad voltage configuration which I am referring to is
MMC specific and applicable only when pad is configured in MMC mode. So
technically it is not simply common pad voltage configuration.


And I am still not sure regulator framework would be right fit for
this. Pinctrl would have been right fit, but...since I saw f_sdh30
driver is already doing this, which is easy fit; so adopted the same.

Thanks,
Vaibhav
--
To unsubscribe from this list: send the line "unsubscribe linux-kernel" in
the body of a message to majordomo@vger.kernel.org
More majordomo info at  http://vger.kernel.org/majordomo-info.html
Please read the FAQ at  http://www.tux.org/lkml/

Back to linux.kernel | Previous | Next — Previous in thread | Next in thread | Find similar | Unroll thread


Thread

Re: [RFC 2/3] mmc: sdhci: add host_ops->voltage_switch callback for  all other voltages Ulf Hansson <ulf.hansson@linaro.org> - 2015-09-14 11:40 +0200
  Re: [RFC 2/3] mmc: sdhci: add host_ops->voltage_switch callback for  all other voltages Vaibhav Hiremath <vaibhav.hiremath@linaro.org> - 2015-09-14 11:50 +0200
    Re: [RFC 2/3] mmc: sdhci: add host_ops->voltage_switch callback for  all other voltages Ulf Hansson <ulf.hansson@linaro.org> - 2015-09-14 12:40 +0200
      Re: [RFC 2/3] mmc: sdhci: add host_ops->voltage_switch callback for  all other voltages Vaibhav Hiremath <vaibhav.hiremath@linaro.org> - 2015-09-14 14:50 +0200
        Re: [RFC 2/3] mmc: sdhci: add host_ops->voltage_switch callback for  all other voltages Vaibhav Hiremath <vaibhav.hiremath@linaro.org> - 2015-09-14 14:50 +0200

csiph-web