Groups | Search | Server Info | Keyboard shortcuts | Login | Register [http] [https] [nntp] [nntps]
Groups > de.sci.electronics > #186972 > unrolled thread
| Started by | Axel_Berger@b.maus.de (Axel Berger) |
|---|---|
| First post | 2015-06-13 05:43 +0200 |
| Last post | 2015-06-13 05:43 +0200 |
| Articles | 1 — 1 participant |
Back to article view | Back to de.sci.electronics
This discussion starts older than the indexed window; earlier articles aren't shown. The article labeled Started by
below is the oldest one visible, not the original post.
Re: Re: Ist Smart Metering (intelligente elektronische Stromzähler) in Deutschland schon ein Thema das verunsichert? Axel_Berger@b.maus.de (Axel Berger) - 2015-06-13 05:43 +0200
| From | Axel_Berger@b.maus.de (Axel Berger) |
|---|---|
| Date | 2015-06-13 05:43 +0200 |
| Subject | Re: Re: Ist Smart Metering (intelligente elektronische Stromzähler) in Deutschland schon ein Thema das verunsichert? |
| Message-ID | <201506130543.a42901@b.maus.de> |
=?windows-1252?Q?Christoph_M=FCller?= wrote on Fri, 15-06-12 16:45: >ohne dass sich das nennenswert auf den elektrischen Wirkungsgrad der >Anlage auswirken wnrde. Ich habe so etwas um die 550 Cel im Kopf. (820-290)/820 = 64 % (820-370)/820 = 55 % Das sind immerhin 14 % Unterschied in der Größe, die den Verkaufserlös dominiert. Bei Kernkraft mir 330 Cel sieht es noch erheblich schlimmer aus.
Back to top | Article view | de.sci.electronics
csiph-web