On 6/10/2015 6:43 PM, Max wrote:
> I have done a SMART short self test of the suspect hard drive. Here is
> the log:
>
> smartctl 5.43 2012-06-30 r3573 [i686-linux-3.10.4-pmagic] (local build)
> Copyright (C) 2002-12 by Bruce Allen, http://smartmontools.sourceforge.net
>
> === START OF INFORMATION SECTION ===
> Model Family: Hitachi Travelstar 5K500.B
> Device Model: Hitachi HTS545050B9A300
> Serial Number: 100527PBN40017DEYYVE
> LU WWN Device Id: 5 000cca 5f1d470ce
> Firmware Version: PB4OC64G
> User Capacity: 500,107,862,016 bytes [500 GB]
> Sector Size: 512 bytes logical/physical
> Device is: In smartctl database [for details use: -P show]
> ATA Version is: 8
> ATA Standard is: ATA-8-ACS revision 6
> Local Time is: Tue Oct 6 16:31:35 2015 WST
> SMART support is: Available - device has SMART capability.
> SMART support is: Enabled
>
> === START OF READ SMART DATA SECTION ===
> SMART overall-health self-assessment test result: PASSED
>
> General SMART Values:
> Offline data collection status: (0x00) Offline data collection activity
> was never started.
> Auto Offline Data Collection: Disabled.
> Self-test execution status: ( 0) The previous self-test
> routine completed
> without error or no self-test has ever
> been run.
> Total time to complete Offline
> data collection: ( 645) seconds.
> Offline data collection
> capabilities: (0x5b) SMART execute Offline immediate.
> Auto Offline data collection on/off support.
> Suspend Offline collection upon new
> command.
> Offline surface scan supported.
> Self-test supported.
> No Conveyance Self-test supported.
> Selective Self-test supported.
> SMART capabilities: (0x0003) Saves SMART data before entering
> power-saving mode.
> Supports SMART auto save timer.
> Error logging capability: (0x01) Error logging supported.
> General Purpose Logging supported.
> Short self-test routine
> recommended polling time: ( 2) minutes.
> Extended self-test routine
> recommended polling time: ( 158) minutes.
> SCT capabilities: (0x003d) SCT Status supported.
> SCT Error Recovery Control supported.
> SCT Feature Control supported.
> SCT Data Table supported.
>
> SMART Attributes Data Structure revision number: 16
> Vendor Specific SMART Attributes with Thresholds:
> ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE
> UPDATED WHEN_FAILED RAW_VALUE
> 1 Raw_Read_Error_Rate 0x000b 076 076 062 Pre-fail s
> - 79889020
> 2 Throughput_Performance 0x0005 100 100 040 Pre-fail
> ine - 0
> 3 Spin_Up_Time 0x0007 149 149 033 Pre-fail s
> - 2
> 4 Start_Stop_Count 0x0012 099 099 000 Old_age ys
> - 2144
----
That is probably your problem, in general, the more often you power
up/down a disk the shorter its life.
> 5 Reallocated_Sector_Ct 0x0033 095 095 005 Pre-fail s
> - 328
> 7 Seek_Error_Rate 0x000b 100 100 067 Pre-fail s
> - 0
> 8 Seek_Time_Performance 0x0005 100 100 040 Pre-fail
> ine - 0
> 9 Power_On_Hours 0x0012 098 098 000 Old_age ys
> - 1221
> 10 Spin_Retry_Count 0x0013 100 100 060 Pre-fail s
> - 0
> 12 Power_Cycle_Count 0x0032 099 099 000 Old_age ys
> - 2137
> 191 G-Sense_Error_Rate 0x000a 100 100 000 Old_age ys
> - 0
> 192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age ys
> - 42
> 193 Load_Cycle_Count 0x0012 099 099 000 Old_age ys
> - 16982
> 194 Temperature_Celsius 0x0002 211 211 000 Old_age ys
> - 26 (Min/Max 12/44)
> 196 Reallocated_Event_Count 0x0032 100 100 000 Old_age ys
> - 343
> 197 Current_Pending_Sector 0x0022 100 100 000 Old_age ys
> - 347
> 198 Offline_Uncorrectable 0x0008 100 100 000 Old_age
> line - 0
> 199 UDMA_CRC_Error_Count 0x000a 200 200 000 Old_age ys
> - 0
> 223 Load_Retry_Count 0x000a 100 100 000 Old_age ys
> - 0
>
> SMART Error Log Version: 1
> ATA Error Count: 42 (device log contains only the most recent five errors)
> CR = Command Register [HEX]
> FR = Features Register [HEX]
> SC = Sector Count Register [HEX]
> SN = Sector Number Register [HEX]
> CL = Cylinder Low Register [HEX]
> CH = Cylinder High Register [HEX]
> DH = Device/Head Register [HEX]
> DC = Device Command Register [HEX]
> ER = Error register [HEX]
> ST = Status register [HEX]
> Powered_Up_Time is measured from power on, and printed as
> DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
> SS=sec, and sss=millisec. It "wraps" after 49.710 days.
>
> Error 42 occurred at disk power-on lifetime: 1219 hours (50 days + 19
> hours)
> When the command that caused the error occurred, the device was active
> or idle.
>
> After command completion occurred, registers were:
> ER ST SC SN CL CH DH
> -- -- -- -- -- -- --
> 40 51 5c eb 7f dc e2 Error: UNC 92 sectors at LBA = 0x02dc7feb =
> 48005099
>
> Commands leading to the command that caused the error were:
> CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
> -- -- -- -- -- -- -- -- ---------------- --------------------
> 25 00 7f c8 7f dc e0 00 00:00:25.400 READ DMA EXT
> 25 00 7f 49 7f dc e0 00 00:00:20.900 READ DMA EXT
> 25 00 7f ca 7e dc e0 00 00:00:11.400 READ DMA EXT
> 25 00 01 a9 82 dc e0 00 00:00:11.400 READ DMA EXT
> 25 00 16 93 82 dc e0 00 00:00:11.300 READ DMA EXT
>
> Error 41 occurred at disk power-on lifetime: 1219 hours (50 days + 19
> hours)
> When the command that caused the error occurred, the device was active
> or idle.
>
> After command completion occurred, registers were:
> ER ST SC SN CL CH DH
> -- -- -- -- -- -- --
> 40 51 3d 0c 7f dc e2 Error: UNC 61 sectors at LBA = 0x02dc7f0c =
> 48004876
>
> Commands leading to the command that caused the error were:
> CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
> -- -- -- -- -- -- -- -- ---------------- --------------------
> 25 00 7f ca 7e dc e0 00 00:00:23.800 READ DMA EXT
> 25 00 01 a9 82 dc e0 00 00:00:23.800 READ DMA EXT
> 25 00 16 93 82 dc e0 00 00:00:22.900 READ DMA EXT
> 25 00 02 c8 7e dc e0 00 00:00:22.900 READ DMA EXT
> 25 00 02 c8 7e dc e0 00 00:00:22.500 READ DMA EXT
>
> Error 40 occurred at disk power-on lifetime: 1219 hours (50 days + 19
> hours)
> When the command that caused the error occurred, the device was active
> or idle.
>
> After command completion occurred, registers were:
> ER ST SC SN CL CH DH
> -- -- -- -- -- -- --
> 40 51 0e 62 09 00 e0 Error: UNC 14 sectors at LBA = 0x00000962 = 2402
>
> Commands leading to the command that caused the error were:
> CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
> -- -- -- -- -- -- -- -- ---------------- --------------------
> 25 00 10 60 09 00 e0 00 00:00:09.200 READ DMA EXT
> 25 00 02 0a a8 0f e0 00 00:00:09.200 READ DMA EXT
> 25 00 02 00 a8 0f e0 00 00:00:09.200 READ DMA EXT
> 25 00 10 00 08 00 e0 00 00:00:09.200 READ DMA EXT
> 25 00 10 00 08 00 e0 00 00:00:09.100 READ DMA EXT
>
> Error 39 occurred at disk power-on lifetime: 1219 hours (50 days + 19
> hours)
> When the command that caused the error occurred, the device was active
> or idle.
>
> After command completion occurred, registers were:
> ER ST SC SN CL CH DH
> -- -- -- -- -- -- --
> 40 51 5c ed 7e dc e2 Error: UNC 92 sectors at LBA = 0x02dc7eed =
> 48004845
>
> Commands leading to the command that caused the error were:
> CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
> -- -- -- -- -- -- -- -- ---------------- --------------------
> 25 00 7f ca 7e dc e0 00 00:00:57.900 READ DMA EXT
> 25 00 01 a9 82 dc e0 00 00:00:57.800 READ DMA EXT
> 25 00 16 93 82 dc e0 00 00:00:56.300 READ DMA EXT
> 25 00 02 c8 7e dc e0 00 00:00:56.300 READ DMA EXT
> 25 00 02 c8 7e dc e0 00 00:00:55.600 READ DMA EXT
>
> Error 38 occurred at disk power-on lifetime: 1213 hours (50 days + 13
> hours)
> When the command that caused the error occurred, the device was active
> or idle.
>
> After command completion occurred, registers were:
> ER ST SC SN CL CH DH
> -- -- -- -- -- -- --
> 40 51 01 28 09 00 40 Error: UNC at LBA = 0x00000928 = 2344
>
> Commands leading to the command that caused the error were:
> CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
> -- -- -- -- -- -- -- -- ---------------- --------------------
> 42 00 01 28 09 00 40 00 00:43:03.700 READ VERIFY SECTOR(S) EXT
> 42 00 01 27 09 00 40 00 00:43:03.700 READ VERIFY SECTOR(S) EXT
> 42 00 01 26 09 00 40 00 00:43:03.700 READ VERIFY SECTOR(S) EXT
> 42 00 01 25 09 00 40 00 00:43:03.700 READ VERIFY SECTOR(S) EXT
> 42 00 01 24 09 00 40 00 00:43:03.700 READ VERIFY SECTOR(S) EXT
>
> SMART Self-test log structure revision number 1
> Num Test_Description Status Remaining
> LifeTime(hours) LBA_of_first_error
> # 1 Short offline Completed: read failure 80% 1221
> 4294905856
> # 2 Short offline Interrupted (host reset) 30% 9 -
> # 3 Short offline Completed: read failure 10% 1214
> 976158933
> # 4 Short offline Completed: read failure 40% 1212 2344
> # 5 Extended offline Aborted by host 90% 2 -
> # 6 Short offline Completed: read failure 80% 1212
> 4294906201
>
> SMART Selective self-test log data structure revision number 1
> SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
> 1 0 0 Not_testing
> 2 0 0 Not_testing
> 3 0 0 Not_testing
> 4 0 0 Not_testing
> 5 0 0 Not_testing
> Selective self-test flags (0x0):
> After scanning selected spans, do NOT read-scan remainder of disk.
> If Selective self-test is pending on power-up, resume after 0 minute delay.
Back to aus.computers | Previous | Next — Previous in thread | Next in thread | Find similar
SMART self test log "Max" <max@val.morgan> - 2015-10-06 16:43 +0800
Re: SMART self test log "Rod Speed" <rod.speed.aaa@gmail.com> - 2015-10-06 19:58 +1100
Re: SMART self test log keithr0 <user@account.invalid> - 2015-10-07 22:35 +1000
Re: SMART self test log "Rod Speed" <rod.speed.aaa@gmail.com> - 2015-10-08 15:38 +1100
Re: SMART self test log Xeno <xenolith@optusnet.com.au> - 2015-10-08 00:29 +1100
Re: SMART self test log "Max" <max@val.morgan> - 2015-10-08 11:44 +0800
Re: SMART self test log Xeno <xenolith@optusnet.com.au> - 2015-10-08 15:30 +1100
Re: SMART self test log "Rod Speed" <rod.speed.aaa@gmail.com> - 2015-10-08 16:07 +1100
Re: SMART self test log keithr0 <user@account.invalid> - 2015-10-08 21:56 +1000
Re: SMART self test log Xeno <xenolith@optusnet.com.au> - 2015-10-08 23:32 +1100