Groups | Search | Server Info | Keyboard shortcuts | Login | Register [http] [https] [nntp] [nntps]
Groups > linux.debian.user > #212242
| From | Gene Heskett <gheskett@shentel.net> |
|---|---|
| Newsgroups | linux.debian.user |
| Subject | Re: 3 phase power converters |
| Date | 2019-08-04 18:00 +0200 |
| Message-ID | <yrr5o-164-9@gated-at.bofh.it> (permalink) |
| References | <yrdF7-199-1@gated-at.bofh.it> <yrg9X-2RX-1@gated-at.bofh.it> <yrpZE-t2-15@gated-at.bofh.it> |
| Organization | none,nada,zip |
On Sunday 04 August 2019 10:45:08 John Hasler wrote: > Gene writes: > > Three phase, at most any frequency can be had a lot cheaper at up to > > 10 horse or so by using a suitably sized VFD. > > Yes. Don't buy a static or rotary converter for a single machine. > They only make sense these days if you can build them at no cost with > stuff you have laying around. > > Put an external fan on your motor. If you are going to operate at > those frequencies a thermistor in the windings would also be a good > idea. The motor is very inefficient down there so you want to keep an > eye on the temperature even with forced cooling. The thermistor can > also control the fan. > > You can get more torque at high frequencies if you up the voltage, but > most VFDs can't do that. Besides, you'd be pushing the voltage rating > on the insulation. > > One reason to consider a motor-generator set (or utility supplied > three phase) for a shop full of VFD-equipped three-phase machines is > that VFDs operating from single phase are limited by the need for > large filter capacitors. And that plays hob with the power factor. But with 6 houses on that can, and no one else with machinery, pure residential loads, I don't figure my 2 vfd's are going to be noticed. The 2nd one is a 127 volt input, driving a 1.5 horse water cooled spindle on a 6040 gantry style mill, can do 24k rpms at full 400 hz song. And actually, I have a dc motor supply I have to softstart, too many u-f's in the filter bank, a hard start trips a 30A (and definitely sick bird breaker). The softstart lets me use a just barely legal 20A breaker. Normal draw is under 4 amps when the machine is working unless its rigid tapping with a big tap. But this is a long ways offtopic, so last post. Cheers, Gene Heskett -- "There are four boxes to be used in defense of liberty: soap, ballot, jury, and ammo. Please use in that order." -Ed Howdershelt (Author) If we desire respect for the law, we must first make the law respectable. - Louis D. Brandeis Genes Web page <http://geneslinuxbox.net:6309/gene>
Back to linux.debian.user | Previous | Next — Previous in thread | Find similar | Unroll thread
3 phase power converters (was: Re: 3 phase power (was Re: Wireless home LAN - WiFi vs Bluetooth?)) rhkramer@gmail.com - 2019-08-04 03:40 +0200
Re: 3 phase power converters John Hasler <jhasler@newsguy.com> - 2019-08-04 05:40 +0200
Re: 3 phase power converters Gene Heskett <gheskett@shentel.net> - 2019-08-04 06:20 +0200
Re: 3 phase power converters John Hasler <jhasler@newsguy.com> - 2019-08-04 16:50 +0200
Re: 3 phase power converters Gene Heskett <gheskett@shentel.net> - 2019-08-04 18:00 +0200