On 1/23/25 1:13 PM, rbowman wrote:
> On Thu, 23 Jan 2025 07:17:52 -0600, chrisv wrote:
> 
>> Yeah the water coolers are also now getting common.  Personally I feel
>> the power consumption is getting out of hand, if water cooling is
>> needed.  But then I'm not in need of a high-end CPU really using all of
>> its cores, either.
> 
> Years ago we used water cooling on an prototype machine. It was a 50 KW
> Colpitts oscillator powered by a very large Eimac tube, not a computer.
> There must be some corollary to Moore's law where power consumption is
> inversely proportional to device complexity and doubles every two years.

More complicated thermal management systems become more common as one 
moves up in total power and system density.  Plus requirements play a 
part too:  a simple rule of thumb is that a distilled water system has 
~twice the heat transfer capacity as the same design after replacing the 
water with antifreeze.

For forgoing liquid cooling, I can recall attending a DARPA conference 
on a "DARPA Hard" technology initiative they had for thermal management 
stuff, as I was working on a heat spreader that used Thermal Pyrolitic 
Graphite (TPG) to get rid of a liquid cooling loop under the chip; if 
memory serves, it was capable of roughly 200W/cm^2 extraction, which was 
good for getting the source heat concentration out of the guts and back 
to where we had a more generous space claim to move it off platform.

And from a Moore's Law perspective, we were investing in chip efficiency 
to get the original heat source load down ... was successful in doubling 
the efficiency and was closing in on triple when the customer lost 
interest due to non-tech factors.  It will come back around, eventually.


-hh

Back to comp.os.linux.advocacy | Previous | NextPrevious in thread | Find similar | Unroll thread


Thread

Mrs. vallor's Linux workstation is online vallor <vallor@cultnix.org> - 2025-01-22 19:18 +0000
  Re: Mrs. vallor's Linux workstation is online vallor <vallor@cultnix.org> - 2025-01-22 19:56 +0000
    Re: Mrs. vallor's Linux workstation is online -hh <recscuba_google@huntzinger.com> - 2025-01-22 15:55 -0500
  Re: Mrs. vallor's Linux workstation is online chrisv <chrisv@nospam.invalid> - 2025-01-22 17:42 -0600
    Re: Mrs. vallor's Linux workstation is online vallor <vallor@cultnix.org> - 2025-01-23 01:33 +0000
      Re: Mrs. vallor's Linux workstation is online chrisv <chrisv@nospam.invalid> - 2025-01-23 07:17 -0600
        Re: Mrs. vallor's Linux workstation is online rbowman <bowman@montana.com> - 2025-01-23 18:13 +0000
          Re: Mrs. vallor's Linux workstation is online chrisv <chrisv@nospam.invalid> - 2025-01-23 14:37 -0600
            Re: Mrs. vallor's Linux workstation is online rbowman <bowman@montana.com> - 2025-01-24 00:52 +0000
          Re: Mrs. vallor's Linux workstation is online -hh <recscuba_google@huntzinger.com> - 2025-01-23 15:48 -0500

csiph-web