Groups | Search | Server Info | Keyboard shortcuts | Login | Register [http] [https] [nntp] [nntps]
Groups > linux.kernel > #1486776
| From | Sebastian Reichel <sre@kernel.org> |
|---|---|
| Newsgroups | linux.kernel |
| Subject | Re: [PATCH] sbs-battery: make writes to ManufacturerAccess optional |
| Date | 2016-09-19 21:10 +0200 |
| Message-ID | <sjc70-Xi-25@gated-at.bofh.it> (permalink) |
| References | <sfjA5-5sJ-7@gated-at.bofh.it> |
| Organization | linux.* mail to news gateway |
[Multipart message — attachments visible in raw view] - view raw
Hi, On Thu, Sep 08, 2016 at 07:10:00PM -0700, Guenter Roeck wrote: > According to the Smart Battery Data Specification, the use > of ManufacturerAcess (register 0x0) is implementation-defined. > It appears that some batteries use writes to this register > in order to implement certain functionality, but others may > simply NAK all writes to it. As a result, write failures to > ManufacturerAccess should not be used as an indicator of > battery presence, nor as a failure to enter sleep mode. > > The failed write access was seen with SANYO AP13J3K. > > Cc: Brian Norris <briannorris@chromium.org> > Signed-off-by: Guenter Roeck <linux@roeck-us.net> Thanks, queued. -- Sebastian
Back to linux.kernel | Previous | Next | Find similar | Unroll thread
Re: [PATCH] sbs-battery: make writes to ManufacturerAccess optional Sebastian Reichel <sre@kernel.org> - 2016-09-19 21:10 +0200