Over current protection is missing descriptions for documentation.
Fixes: 3a003baeec24 ("regulator: Add over current protection (OCP) support")
Signed-off-by: Luis de Bethencourt <luisbg@osg.samsung.com>
---
Hi,
Sorry. I missed this second missing description related to over current
protection in regulator_linear_range struct.
Thanks,
Luis
include/linux/regulator/driver.h | 3 +++
include/linux/regulator/machine.h | 1 +
2 files changed, 4 insertions(+)
diff --git a/include/linux/regulator/driver.h b/include/linux/regulator/driver.h
index cd271e8..8ea86dc 100644
--- a/include/linux/regulator/driver.h
+++ b/include/linux/regulator/driver.h
@@ -93,6 +93,9 @@ struct regulator_linear_range {
* @get_current_limit: Get the configured limit for a current-limited regulator.
* @set_input_current_limit: Configure an input limit.
*
+ * @set_over_current_protection: Support capability of automatically shutting
+ * down when detecting an over current event.
+ *
* @set_active_discharge: Set active discharge enable/disable of regulators.
*
* @set_mode: Set the configured operating mode for the regulator.
diff --git a/include/linux/regulator/machine.h b/include/linux/regulator/machine.h
index 5d627c8..ad3e515 100644
--- a/include/linux/regulator/machine.h
+++ b/include/linux/regulator/machine.h
@@ -97,6 +97,7 @@ struct regulator_state {
* @ramp_disable: Disable ramp delay when initialising or when setting voltage.
* @soft_start: Enable soft start so that voltage ramps slowly.
* @pull_down: Enable pull down when regulator is disabled.
+ * @over_current_protection: Auto disable on over current event.
*
* @input_uV: Input voltage for regulator when supplied by another regulator.
*
--
2.5.1
Back to linux.kernel | Previous | Next — Previous in thread | Next in thread | Find similar | Unroll thread
[PATCH 0/2] regulator: add missing descriptions for docs Luis de Bethencourt <luisbg@osg.samsung.com> - 2016-03-23 12:30 +0100
[PATCH 2/2] regulator: add missing descriptions in regulator_desc Luis de Bethencourt <luisbg@osg.samsung.com> - 2016-03-23 12:30 +0100
Applied "regulator: add missing descriptions in regulator_desc" to the regulator tree Mark Brown <broonie@kernel.org> - 2016-03-23 14:50 +0100
[PATCH 1/2] regulator: add missing description for set_over_current_protection Luis de Bethencourt <luisbg@osg.samsung.com> - 2016-03-23 12:30 +0100
[PATCH 1/2 v2] regulator: add missing description for set_over_current_protection Luis de Bethencourt <luisbg@osg.samsung.com> - 2016-03-23 12:40 +0100