Groups | Search | Server Info | Keyboard shortcuts | Login | Register [http] [https] [nntp] [nntps]
Groups > comp.arch.embedded > #28886
| From | David Brown <david.brown@hesbynett.no> |
|---|---|
| Newsgroups | comp.arch.embedded |
| Subject | Re: Multidrop bus on Windows |
| Date | 2019-10-03 11:12 +0200 |
| Organization | A noiseless patient Spider |
| Message-ID | <qn4e1f$iq0$1@dont-email.me> (permalink) |
| References | (3 earlier) <a0o8pe19q2u01l0ut963d5lcqnkh0kfp93@4ax.com> <qn1t5m$ook$1@dont-email.me> <0j5apehok86r0hek2ro7ss73fi2mqb8nis@4ax.com> <qn47ed$f3g$1@dont-email.me> <ae9bpedcvst1dv7v9mfss2avt1lrmui04m@4ax.com> |
On 03/10/2019 09:59, upsidedown@downunder.com wrote: > On Thu, 3 Oct 2019 09:19:41 +0200, David Brown > <david.brown@hesbynett.no> wrote: > >> On 03/10/2019 00:11, upsidedown@downunder.com wrote: >>> On Wed, 2 Oct 2019 12:12:06 +0200, David Brown >>> <david.brown@hesbynett.no> wrote: >>> >> There was a common trick of sending an extra 0xff character beyond the >> telegram you wanted to send, and when you got the interrupt as that >> moved into the transmit register, you turned off the RS-485 driver. >> This had a risk of letting a start bit, or part of a start bit, get >> through - but for most protocols that was not an issue as it would be >> ignored by the receiver. > > This is true for most protocols, but not with Modbus RTU, since if the > start bit gets trough, it calculates the frame length incorrectly and > tries to locate the CRC from the wrong position. Modbus requires a break before the start of the telegram - at least 3.5 character times. A slave that checks this will not be bothered by the noise. Failing that, it is not uncommon to avoid address 255 and consider a start address of 255 as noise. But it certainly /can/ be an issue, and should be considered when designing a system. > >> Still, it is /much/ nicer with a device like the FTDI chips that handles >> the drive enable timing automatically. > > So does some UARTs in a PCI cards. Yes. But those are often not directly compatible with standard ports. > >>>> It is a /long/ time since I have used "real" UART devices on a PC. I >>>> almost invariably use FTDI chip's USB UART cables and converters. These >>>> have no problem with RS-485 direction switching - I've run them at 3 MB. >>>> (As usual, life is much easier with Linux than with Windows for such >>>> things - in particular, you have no messing about with drivers, and no >>>> run-away comms port numbering.) >>> >>> I once tried some USB to serial converters, one crashed the Windows. >>> >>> An other mixed the enumeration when two or more such converters were >>> plugged into USB ports in different order, sending communication to >>> wrong serial lines with potentially lethal consequences. >> >> There is a big challenge with these kinds of devices and serial port >> numbers in Windows. Windows gives a new comms port to each new device >> it sees, and sometimes to the same device on a different USB bus. It >> should not mix up the numbers - but it is very easy for users to do so - >> if you have two devices and they are on comms port numbers 45 and 57, >> which is which? >> >> Programs that are aware of the USB nature of the ports can make this a >> lot easier - it's not hard to use Win32 calls or the FTDI DLL's to >> identify serial numbers of devices or the physical placement on bus and >> hub trees. > > The serial number trick works, but requires an unique serial number > .e.g. with a separate serial number chip or some Flash memory to store > a (hopefully) unique serial number at first use. Any USB serial converter you buy should have a unique serial number. If they don't, then try buying from a reputable source instead of something that fell off an eBay truck. > > Relying on device position in a hub tree is a no no thing, since more > hub levels may have to be added if more USB devices are inserted. It is a "yes yes" thing for many people in many environments, because it is obvious and convenient - it's just like plugging your RS-232 line into "com1" at the back of an ancient PC. The options are there, and it's up to you to pick the ones that suit best. > >> >> Or you can use Linux, which makes it a lot easier to do that kind of thing. >> >>> >>> These days I prefer ethernet to serial converters with proper Rx/Tx >>> hardware switching. These work fine and you get 100 m range and >>> galvanic isolation for 'free'. >> >> Ethernet to serial converters can be useful, but have their own >> complications - you have a lot more jitter in timings, and you have >> challenges about identifying and addressing them on the network. > > Use fixed IP-addresses in a private address area such as 192.168.x.y. > That can work - or it can lead to complications and conflicts. And it either means /very/ expensive converter devices with some way of viewing and setting the IP addresses, or chicken-and-egg time-wasting for configuration. >> The RS-485 driving issue is no different from what you get with USB >> RS-485 converters - the bus driver is enabled if and only if you are >> transmitting. >> >>> >>> Some early ethernet to serial converters waited a looong time before >>> forwarding the last Rx character to ethernet. Some had adjustable time >>> settings with minimum settings of 10 ms :-(. This did make these >>> devices useless for high speed half duplex traffic. Modern versions >>> forwards the last character after one or few character time idle >>> period detected on the Rx serial line. >>> >> >> This is always going to be an issue. It is an issue with USB too, but >> less so than with Ethernet. >> >> I have run USB serial ports at 3 Mbaud. No Ethernet to serial converter >> is going to send the last character within one or two character time >> periods at these speeds. (Nor will USB devices, but they'll be closer >> and less varied.) > > For accurate timing, do not use TCP between PC and converter. UDP will > give a more predictable timing or just raw MAC framing, but this is > much harder to use on Windows. Raw MAC framing is out of the question for Windows. UDP is a better than TCP/IP for low latency (but loses you the joys of redirecting your traffic over ssh links, VPNs, the internet, etc.), but it is certainly far from real-time. > > A converter based on the QUICC co-processor (found on MC68360 and some > PPC models) should be able to handle a few fast serial lines. But of > course, these processors are an overkill for such simple task. > Yes, that is overkill.
Back to comp.arch.embedded | Previous | Next — Previous in thread | Next in thread | Find similar | Unroll thread
Multidrop bus on Windows pozz <pozzugno@gmail.com> - 2019-10-01 16:02 +0200
Re: Multidrop bus on Windows Dave Nadler <drn@nadler.com> - 2019-10-01 08:01 -0700
Re: Multidrop bus on Windows pozz <pozzugno@gmail.com> - 2019-10-02 09:04 +0200
Re: Multidrop bus on Windows upsidedown@downunder.com - 2019-10-02 11:33 +0300
Re: Multidrop bus on Windows David Brown <david.brown@hesbynett.no> - 2019-10-02 12:12 +0200
Re: Multidrop bus on Windows Dave Nadler <drn@nadler.com> - 2019-10-02 04:59 -0700
Re: Multidrop bus on Windows upsidedown@downunder.com - 2019-10-03 01:11 +0300
Re: Multidrop bus on Windows Rick C <gnuarm.deletethisbit@gmail.com> - 2019-10-02 19:06 -0700
Re: Multidrop bus on Windows upsidedown@downunder.com - 2019-10-03 07:39 +0300
Re: Multidrop bus on Windows Rick C <gnuarm.deletethisbit@gmail.com> - 2019-10-02 22:16 -0700
Re: Multidrop bus on Windows upsidedown@downunder.com - 2019-10-03 09:10 +0300
Re: Multidrop bus on Windows Rick C <gnuarm.deletethisbit@gmail.com> - 2019-10-03 07:53 -0700
Re: Multidrop bus on Windows David Brown <david.brown@hesbynett.no> - 2019-10-04 08:54 +0200
Re: Multidrop bus on Windows upsidedown@downunder.com - 2019-10-04 12:44 +0300
Re: Multidrop bus on Windows David Brown <david.brown@hesbynett.no> - 2019-10-04 13:00 +0200
Re: Multidrop bus on Windows upsidedown@downunder.com - 2019-10-04 15:54 +0300
Re: Multidrop bus on Windows David Brown <david.brown@hesbynett.no> - 2019-10-04 15:13 +0200
Re: Multidrop bus on Windows upsidedown@downunder.com - 2019-10-04 16:40 +0300
Re: Multidrop bus on Windows David Brown <david.brown@hesbynett.no> - 2019-10-04 16:49 +0200
Re: Multidrop bus on Windows Grant Edwards <invalid@invalid.invalid> - 2019-10-04 16:14 +0000
Re: Multidrop bus on Windows upsidedown@downunder.com - 2019-10-05 14:24 +0300
Re: Multidrop bus on Windows David Brown <david.brown@hesbynett.no> - 2019-10-03 09:35 +0200
Re: Multidrop bus on Windows Grant Edwards <invalid@invalid.invalid> - 2019-10-03 14:08 +0000
Re: Multidrop bus on Windows David Brown <david.brown@hesbynett.no> - 2019-10-04 08:59 +0200
Re: Multidrop bus on Windows Rick C <gnuarm.deletethisbit@gmail.com> - 2019-10-03 08:04 -0700
Re: Multidrop bus on Windows David Brown <david.brown@hesbynett.no> - 2019-10-04 09:43 +0200
Re: Multidrop bus on Windows Rick C <gnuarm.deletethisbit@gmail.com> - 2019-10-04 03:16 -0700
Re: Multidrop bus on Windows David Brown <david.brown@hesbynett.no> - 2019-10-04 13:10 +0200
Re: Multidrop bus on Windows Stef <stef33d@yahooI-N-V-A-L-I-D.com.invalid> - 2019-10-03 22:12 +0200
Re: Multidrop bus on Windows David Brown <david.brown@hesbynett.no> - 2019-10-03 09:19 +0200
Re: Multidrop bus on Windows upsidedown@downunder.com - 2019-10-03 10:59 +0300
Re: Multidrop bus on Windows David Brown <david.brown@hesbynett.no> - 2019-10-03 11:12 +0200
Re: Multidrop bus on Windows upsidedown@downunder.com - 2019-10-03 20:15 +0300
Re: Multidrop bus on Windows David Brown <david.brown@hesbynett.no> - 2019-10-04 09:45 +0200
Re: Multidrop bus on Windows upsidedown@downunder.com - 2019-10-04 12:58 +0300
Re: Multidrop bus on Windows Grant Edwards <invalid@invalid.invalid> - 2019-10-03 14:04 +0000
Re: Multidrop bus on Windows David Brown <david.brown@hesbynett.no> - 2019-10-04 09:47 +0200
Re: Multidrop bus on Windows David Brown <david.brown@hesbynett.no> - 2019-10-01 20:44 +0200
Re: Multidrop bus on Windows pozz <pozzugno@gmail.com> - 2019-10-02 09:03 +0200
Re: Multidrop bus on Windows David Brown <david.brown@hesbynett.no> - 2019-10-02 12:14 +0200