On 27/09/2026 07:32, Bill Sloman wrote: > But we haven't been told how Rheem went from mains AC to to the current > that they put through their resistive heaters. It won't have been > through a 50Hz mains transformer - higher frequency transformers are > much cheaper and more compact. Apparently they use a Triac so that they have full control over the power fed into the heaters. The control system seems to attempt to make a kind of PID control loop to keep a constant temperature no matter what the flow rate is. That does explain the large spikes, potentially one every mains half cycle. That kind of control system really needs a lot more than a ferrite to reduce spurious emissions. -- Brian Gregory (in England).
Back to sci.electronics.design | Previous | Next — Previous in thread | Next in thread | Find similar | Unroll thread
Ferrite ID David Lesher <wb8foz@panix.com> - 2026-09-25 15:58 +0000
Re: Ferrite ID John R Walliker <jrwalliker@gmail.com> - 2026-09-25 17:02 +0100
Re: Ferrite ID Bill Sloman <bill.sloman@ieee.org> - 2026-09-26 02:55 +1000
Re: Ferrite ID john larkin <jl@htigct.com> - 2026-09-25 17:13 -0700
Re: Ferrite ID Bill Sloman <bill.sloman@ieee.org> - 2026-09-26 16:39 +1000
Re: Ferrite ID john larkin <jl@glen--canyon.com> - 2026-09-26 09:10 -0700
Re: Ferrite ID Bill Sloman <bill.sloman@ieee.org> - 2026-09-27 16:32 +1000
Re: Ferrite ID Brian Gregory <void-invalid-dead-dontuse@email.invalid> - 2026-09-28 23:30 +0100
Re: Ferrite ID someone <2a59d59e3809f827ce709d3815e3950eef4a6a93af5557a93a7fdfba71460843@example.com> - 2026-09-29 19:15 +0000
Re: Ferrite ID Bill Sloman <bill.sloman@ieee.org> - 2026-09-30 17:24 +1000
Re: Ferrite ID john larkin <jl@glen--canyon.com> - 2026-09-30 07:50 -0700
Re: Ferrite ID someone <2a59d59e3809f827ce709d3815e3950eef4a6a93af5557a93a7fdfba71460843@example.com> - 2026-09-30 20:00 +0000
Re: Ferrite ID Bill Sloman <bill.sloman@ieee.org> - 2026-09-27 16:34 +1000
Re: Ferrite ID someone <2a59d59e3809f827ce709d3815e3950eef4a6a93af5557a93a7fdfba71460843@example.com> - 2026-09-28 16:30 +0000
Re: Ferrite ID someone <2a59d59e3809f827ce709d3815e3950eef4a6a93af5557a93a7fdfba71460843@example.com> - 2026-09-28 16:30 +0000
Re: Ferrite ID someone <2a59d59e3809f827ce709d3815e3950eef4a6a93af5557a93a7fdfba71460843@example.com> - 2026-09-28 16:30 +0000
Re: Ferrite ID Ian <devnul@blackhole.com> - 2026-09-26 11:57 +0100
Re: Ferrite ID Bill Sloman <bill.sloman@ieee.org> - 2026-09-29 00:42 +1000
Re: Ferrite ID Martin Rid <martin_riddle@verison.net> - 2026-09-28 11:04 -0400
Re: Ferrite ID someone <2a59d59e3809f827ce709d3815e3950eef4a6a93af5557a93a7fdfba71460843@example.com> - 2026-10-01 04:15 +0000
Re: Ferrite ID Ian <devnul@blackhole.com> - 2026-09-30 17:47 +0100
csiph-web