Groups | Search | Server Info | Keyboard shortcuts | Login | Register [http] [https] [nntp] [nntps]


Groups > comp.soft-sys.math.mathematica > #5881

Table to calculate faster

From Michelle Maul <michellemaul312@gmail.com>
Newsgroups comp.soft-sys.math.mathematica
Subject Table to calculate faster
Date 2011-10-26 21:44 +0000
Organization Steven M. Christensen and Associates, Inc and MathTensor, Inc.
Message-ID <j89uvc$7i$1@smc.vnet.net> (permalink)

Show all headers | View raw


I am trying to perform a heat transfer calculation on a wall with
transient heating.  I am using rules so that we can easily change the
material.  I want to be able to do several hundred time steps but I am
only able to get about 10 in an hour.  It is a pretty straight forward
calculation so I'm wondering why it is taking so long to compute.
This is a calculation that Excel would be good at because it is taking
data from the cells above it to solve.  Help please

T[0, t_] := (1. -
       2. \[Tau] - (2. \[Tau] Subscript[h, in] \[CapitalDelta]x)/k) T[
      0, t - 1] +
    2. \[Tau] T[1,
      t - 1] + (2. \[Tau] Subscript[h, in] \[CapitalDelta]x)/k*
     Subscript[T, in] /. masonry;

T[m_, t_] := \[Tau] (T[m - 1, t - 1] + T[m + 1, t - 1]) + (1. -
       2. \[Tau]) T[m, t - 1] /. masonry;

T[5, t_] := (1. - 2. \[Tau] -
       2. \[Tau] (Subscript[h, out] \[CapitalDelta]x)/k) T[5,
      t - 1] + 2. \[Tau] T[4, t - 1] +
    2. \[Tau] (Subscript[h, out] \[CapitalDelta]x)/
     k*(Subscript[T, out] /. {x -> t}) +
    2. \[Tau] (\[Kappa] *(Subscript[q,
        solar] /. {x -> t}) \[CapitalDelta]x)/k /. masonry;

solution = Transpose[Table[T[n, x], {n, 0, 5}, {x, 0, 24}]]

Thank you

Back to comp.soft-sys.math.mathematica | Previous | Next | Find similar | Unroll thread


Thread

Table to calculate faster Michelle Maul <michellemaul312@gmail.com> - 2011-10-26 21:44 +0000