DC current sources Clifford Heath <no.spam@please.net> - 2017-05-03 22:15 +1000
Re: DC current sources George Herold <gherold@teachspin.com> - 2017-05-03 05:55 -0700
Re: DC current sources "Ian Field" <gangprobing.alien1@virginmedia.com> - 2017-05-03 19:40 +0100
Re: DC current sources tabbypurr@gmail.com - 2017-05-06 00:39 -0700
Re: DC current sources Martin Brown <'''newspam'''@nezumi.demon.co.uk> - 2017-05-03 14:06 +0100
Re: DC current sources Winfield Hill <hill@rowland.harvard.edu> - 2017-05-03 11:06 -0700
Re: DC current sources "Ian Field" <gangprobing.alien1@virginmedia.com> - 2017-05-03 19:43 +0100
Re: DC current sources Winfield Hill <hill@rowland.harvard.edu> - 2017-05-03 13:02 -0700
Re: DC current sources Winfield Hill <hill@rowland.harvard.edu> - 2017-05-03 17:22 -0700
Re: DC current sources tabbypurr@gmail.com - 2017-05-06 00:41 -0700
Re: DC current sources "dcaster@krl.org" <dcaster@krl.org> - 2017-05-03 06:15 -0700
Re: DC current sources Spehro Pefhany <speffSNIP@interlogDOTyou.knowwhat> - 2017-05-03 11:10 -0400
Re: DC current sources Tim Wescott <tim@seemywebsite.com> - 2017-05-03 11:27 -0500
Re: DC current sources "Ian Field" <gangprobing.alien1@virginmedia.com> - 2017-05-03 19:47 +0100
Re: DC current sources Clifford Heath <no.spam@please.net> - 2017-05-04 12:41 +1000
Re: DC current sources "Ian Field" <gangprobing.alien1@virginmedia.com> - 2017-05-04 20:55 +0100
Re: DC current sources Clifford Heath <no.spam@please.net> - 2017-05-05 08:39 +1000
Re: DC current sources "dcaster@krl.org" <dcaster@krl.org> - 2017-05-03 09:37 -0700
Re: DC current sources Tim Wescott <seemywebsite@myfooter.really> - 2017-05-03 13:53 -0500
Re: DC current sources Clifford Heath <no.spam@please.net> - 2017-05-04 12:24 +1000
Re: DC current sources mike <ham789@netzero.net> - 2017-05-04 00:48 -0700
Re: DC current sources whit3rd <whit3rd@gmail.com> - 2017-05-04 14:09 -0700
Re: DC current sources Clifford Heath <no.spam@please.net> - 2017-05-05 08:42 +1000
Re: DC current sources mike <ham789@netzero.net> - 2017-05-03 13:22 -0700
Re: DC current sources whit3rd <whit3rd@gmail.com> - 2017-05-03 13:25 -0700
Re: DC current sources Lasse Langwadt Christensen <langwadt@fonz.dk> - 2017-05-03 13:45 -0700
Re: DC current sources whit3rd <whit3rd@gmail.com> - 2017-05-03 15:40 -0700
Re: DC current sources Lasse Langwadt Christensen <langwadt@fonz.dk> - 2017-05-03 16:04 -0700
Re: DC current sources krw@notreal.com - 2017-05-03 21:26 -0400
Re: DC current sources Clifford Heath <no.spam@please.net> - 2017-05-04 12:27 +1000
Re: DC current sources John Robertson <spam@flippers.com> - 2017-05-03 22:48 -0700
Re: DC current sources Clifford Heath <no.spam@please.net> - 2017-05-04 16:36 +1000
Re: DC current sources Jasen Betts <jasen@xnet.co.nz> - 2017-05-04 04:59 +0000
Re: DC current sources Chris Jones <lugnut808@spam.yahoo.com> - 2017-05-04 22:50 +1000
Re: DC current sources tabbypurr@gmail.com - 2017-05-06 00:53 -0700
Re: DC current sources John Robertson <spam@flippers.com> - 2017-05-03 23:38 -0700
Re: DC current sources Clifford Heath <no.spam@please.net> - 2017-05-04 16:45 +1000
Re: DC current sources John Robertson <spam@flippers.com> - 2017-05-04 11:16 -0700
Re: DC current sources Winfield Hill <hill@rowland.harvard.edu> - 2017-05-04 14:32 -0700
Re: DC current sources "Ian Field" <gangprobing.alien1@virginmedia.com> - 2017-05-05 20:21 +0100
Re: DC current sources Lasse Langwadt Christensen <langwadt@fonz.dk> - 2017-05-06 05:59 -0700
Re: DC current sources Steve Wilson <no@spam.com> - 2017-05-06 14:04 +0000
Re: DC current sources Robert Baer <robertbaer@localnet.com> - 2017-05-04 19:32 -0800
Re: DC current sources mike <ham789@netzero.net> - 2017-05-05 00:18 -0700
Re: DC current sources Jan Panteltje <pNaOnStPeAlMtje@yahoo.com> - 2017-05-05 08:28 +0000
Re: DC current sources Robert Baer <robertbaer@localnet.com> - 2017-05-05 22:09 -0800
Re: DC current sources Jan Panteltje <pNaOnStPeAlMtje@yahoo.com> - 2017-05-06 06:17 +0000
Re: DC current sources Robert Baer <robertbaer@localnet.com> - 2017-05-06 20:47 -0800
Re: DC current sources Jan Panteltje <pNaOnStPeAlMtje@yahoo.com> - 2017-05-07 08:27 +0000
Re: DC current sources Robert Baer <robertbaer@localnet.com> - 2017-05-05 22:07 -0800
Page 1 of 3 [1] 2 3 Next page →
| From | Clifford Heath <no.spam@please.net> |
|---|---|
| Date | 2017-05-03 22:15 +1000 |
| Subject | DC current sources |
| Message-ID | <5909c9eb$0$34631$b1db1813$15bdbe48@news.astraweb.com> |
A friend works in concrete reinforcing corrosion remediation, and has been asked to take over a project that's underway despite not having been properly designed or specified. The contractors are installing 400 anodes into the structure, and each one needs a specific amount of charge to be deposited into it, all over a week or two. The resistance is unknown and could change from day to day, but the voltage must not rise above +9V, or the titanium wires rapidly corrode. So they want to adjust the current for each anode, probably in the range of 100ma to 3000mA. They're intending to feed the whole protection thing from banks of 12V lead acid batteries, I guess because it's a remote site. The initial thought was to walk around and measure the current on each anode every day, and switch off any that have dumped the required charge... but that's quite labour-intensive. So I was thinking about current regulators. What's the easiest way of sourcing 400 adjustable DC current sources in a short time? I was thinking of LM350T regulators, programmed with a power resistor in the range 0.6-10 ohms... but the 2degC/W heat sink for each one could be an issue (thinking 2A, 14.7V, shorted to earth; 30W). Is there any other off-the-shelf quick solution that comes to mind? Clifford Heath.
[toc] | [next] | [standalone]
| From | George Herold <gherold@teachspin.com> |
|---|---|
| Date | 2017-05-03 05:55 -0700 |
| Message-ID | <15893772-a2d3-4199-b7de-cfe487a7099d@googlegroups.com> |
| In reply to | #458546 |
On Wednesday, May 3, 2017 at 8:15:42 AM UTC-4, Clifford Heath wrote: > A friend works in concrete reinforcing corrosion remediation, > and has been asked to take over a project that's underway > despite not having been properly designed or specified. > > The contractors are installing 400 anodes into the structure, > and each one needs a specific amount of charge to be deposited > into it, all over a week or two. The resistance is unknown and > could change from day to day, but the voltage must not rise > above +9V, or the titanium wires rapidly corrode. So they > want to adjust the current for each anode, probably in the > range of 100ma to 3000mA. They're intending to feed the whole > protection thing from banks of 12V lead acid batteries, I > guess because it's a remote site. > > The initial thought was to walk around and measure the current > on each anode every day, and switch off any that have dumped > the required charge... but that's quite labour-intensive. > > So I was thinking about current regulators. What's the easiest > way of sourcing 400 adjustable DC current sources in a short time? > > I was thinking of LM350T regulators, programmed with a power > resistor in the range 0.6-10 ohms... but the 2degC/W heat sink > for each one could be an issue (thinking 2A, 14.7V, shorted to > earth; 30W). > > Is there any other off-the-shelf quick solution that comes to > mind? > > Clifford Heath. No idea what might work, but there are a lot of "PMIC LED drivers" listed on digikey. (I assume switch mode, but don't know.) George H.
[toc] | [prev] | [next] | [standalone]
| From | "Ian Field" <gangprobing.alien1@virginmedia.com> |
|---|---|
| Date | 2017-05-03 19:40 +0100 |
| Message-ID | <5upOA.1384910$3B6.493340@fx40.am4> |
| In reply to | #458549 |
"George Herold" <gherold@teachspin.com> wrote in message news:15893772-a2d3-4199-b7de-cfe487a7099d@googlegroups.com... > On Wednesday, May 3, 2017 at 8:15:42 AM UTC-4, Clifford Heath wrote: >> A friend works in concrete reinforcing corrosion remediation, >> and has been asked to take over a project that's underway >> despite not having been properly designed or specified. >> >> The contractors are installing 400 anodes into the structure, >> and each one needs a specific amount of charge to be deposited >> into it, all over a week or two. The resistance is unknown and >> could change from day to day, but the voltage must not rise >> above +9V, or the titanium wires rapidly corrode. So they >> want to adjust the current for each anode, probably in the >> range of 100ma to 3000mA. They're intending to feed the whole >> protection thing from banks of 12V lead acid batteries, I >> guess because it's a remote site. >> >> The initial thought was to walk around and measure the current >> on each anode every day, and switch off any that have dumped >> the required charge... but that's quite labour-intensive. >> >> So I was thinking about current regulators. What's the easiest >> way of sourcing 400 adjustable DC current sources in a short time? >> >> I was thinking of LM350T regulators, programmed with a power >> resistor in the range 0.6-10 ohms... but the 2degC/W heat sink >> for each one could be an issue (thinking 2A, 14.7V, shorted to >> earth; 30W). >> >> Is there any other off-the-shelf quick solution that comes to >> mind? >> >> Clifford Heath. > > No idea what might work, but there are a lot of "PMIC LED drivers" listed > on digikey. (I assume switch mode, but don't know.) Current control as the primary regulation mode can be tricky with switchers. There are off the shelf PWM front end chips for dimmable LED bulbs, but I've only seen mains type. It demonstrates the possibility - so a bit of searching might do something.
[toc] | [prev] | [next] | [standalone]
| From | tabbypurr@gmail.com |
|---|---|
| Date | 2017-05-06 00:39 -0700 |
| Message-ID | <ecec68d9-e1ca-4d93-8012-b1186ca152c5@googlegroups.com> |
| In reply to | #458603 |
On Wednesday, 3 May 2017 19:40:06 UTC+1, Ian Field wrote: > Current control as the primary regulation mode can be tricky with switchers. ISTR making 2 transistor smpsus that just switched off when inductor current reached a set value, and on again when it dropped. And a screw for an inductor core. NT
[toc] | [prev] | [next] | [standalone]
| From | Martin Brown <'''newspam'''@nezumi.demon.co.uk> |
|---|---|
| Date | 2017-05-03 14:06 +0100 |
| Message-ID | <oeckl4$1eu9$1@gioia.aioe.org> |
| In reply to | #458546 |
On 03/05/2017 13:15, Clifford Heath wrote: > A friend works in concrete reinforcing corrosion remediation, > and has been asked to take over a project that's underway > despite not having been properly designed or specified. > > The contractors are installing 400 anodes into the structure, > and each one needs a specific amount of charge to be deposited > into it, all over a week or two. The resistance is unknown and > could change from day to day, but the voltage must not rise > above +9V, or the titanium wires rapidly corrode. So they > want to adjust the current for each anode, probably in the > range of 100ma to 3000mA. They're intending to feed the whole > protection thing from banks of 12V lead acid batteries, I > guess because it's a remote site. Why not use a high power switched mode DC to DC converter to supply 8.5v to the anodes through a crude rheostat and power resistor? That way the titanium wires can never be damaged by over voltage no matter what the engineers do to the anode wiring. > The initial thought was to walk around and measure the current > on each anode every day, and switch off any that have dumped > the required charge... but that's quite labour-intensive. You would need to assume in addition that the current was fairly constant to work out how much charge had been delivered to each node. A quick and dirty LED jig to measure voltage across the load would be one way to speed up testing which loads are slow (ie high impedance). I assume that fast, nominal and slow will be good enough here. > So I was thinking about current regulators. What's the easiest > way of sourcing 400 adjustable DC current sources in a short time? > > I was thinking of LM350T regulators, programmed with a power > resistor in the range 0.6-10 ohms... but the 2degC/W heat sink > for each one could be an issue (thinking 2A, 14.7V, shorted to > earth; 30W). > > Is there any other off-the-shelf quick solution that comes to > mind? > > Clifford Heath. LED driver modules but it seems like overkill and unlikely to survive on a building site! (also offers no over voltage protection) -- Regards, Martin Brown
[toc] | [prev] | [next] | [standalone]
| From | Winfield Hill <hill@rowland.harvard.edu> |
|---|---|
| Date | 2017-05-03 11:06 -0700 |
| Message-ID | <oed67g0240p@drn.newsguy.com> |
| In reply to | #458550 |
Martin Brown wrote...
>
>On 03/05/2017 13:15, Clifford Heath wrote:
>> A friend works in concrete reinforcing corrosion remediation,
>> and has been asked to take over a project that's underway
>> despite not having been properly designed or specified.
>>
>> The contractors are installing 400 anodes into the structure,
>> and each one needs a specific amount of charge to be deposited
>> into it, all over a week or two. The resistance is unknown and
>> could change from day to day, but the voltage must not rise
>> above +9V, or the titanium wires rapidly corrode. So they
>> want to adjust the current for each anode, probably in the
>> range of 100ma to 3000mA. They're intending to feed the whole
>> protection thing from banks of 12V lead acid batteries, I
>> guess because it's a remote site.
>
> Why not use a high power switched mode DC to DC converter
> to supply 8.5v to the anodes through a crude rheostat and
> power resistor?
Or buck smps down to 9.7 volts and an LM317 with resistor
current limiting for each, w/o overheating issues. LM317
thermal limits, protecting itself in case of shorts, etc.
--
Thanks,
- Win
[toc] | [prev] | [next] | [standalone]
| From | "Ian Field" <gangprobing.alien1@virginmedia.com> |
|---|---|
| Date | 2017-05-03 19:43 +0100 |
| Message-ID | <uxpOA.1129105$fZ.1074704@fx41.am4> |
| In reply to | #458602 |
"Winfield Hill" <hill@rowland.harvard.edu> wrote in message news:oed67g0240p@drn.newsguy.com... > Martin Brown wrote... >> >>On 03/05/2017 13:15, Clifford Heath wrote: >>> A friend works in concrete reinforcing corrosion remediation, >>> and has been asked to take over a project that's underway >>> despite not having been properly designed or specified. >>> >>> The contractors are installing 400 anodes into the structure, >>> and each one needs a specific amount of charge to be deposited >>> into it, all over a week or two. The resistance is unknown and >>> could change from day to day, but the voltage must not rise >>> above +9V, or the titanium wires rapidly corrode. So they >>> want to adjust the current for each anode, probably in the >>> range of 100ma to 3000mA. They're intending to feed the whole >>> protection thing from banks of 12V lead acid batteries, I >>> guess because it's a remote site. >> >> Why not use a high power switched mode DC to DC converter >> to supply 8.5v to the anodes through a crude rheostat and >> power resistor? > > Or buck smps down to 9.7 volts and an LM317 with resistor > current limiting for each, w/o overheating issues. LM317 > thermal limits, protecting itself in case of shorts, etc. But it won't do the 3A top limit mentioned - the 78xx appnotes show how to increase current with an external bypass transistor, it should work with the 317. There used to be a higher current adjustable in TO3 - no idea whether there still is.
[toc] | [prev] | [next] | [standalone]
| From | Winfield Hill <hill@rowland.harvard.edu> |
|---|---|
| Date | 2017-05-03 13:02 -0700 |
| Message-ID | <oedd1502f0u@drn.newsguy.com> |
| In reply to | #458604 |
Ian Field wrote...
>
> Winfield Hill wrote...
>> Martin Brown wrote...
>>>
>>>On 03/05/2017 13:15, Clifford Heath wrote:
>>>> A friend works in concrete reinforcing corrosion remediation,
>>>> and has been asked to take over a project that's underway
>>>> despite not having been properly designed or specified.
>>>>
>>>> The contractors are installing 400 anodes into the structure,
>>>> and each one needs a specific amount of charge to be deposited
>>>> into it, all over a week or two. The resistance is unknown and
>>>> could change from day to day, but the voltage must not rise
>>>> above +9V, or the titanium wires rapidly corrode. So they
>>>> want to adjust the current for each anode, probably in the
>>>> range of 100ma to 3000mA. They're intending to feed the whole
>>>> protection thing from banks of 12V lead acid batteries, I
>>>> guess because it's a remote site.
>>>
>>> Why not use a high power switched mode DC to DC converter
>>> to supply 8.5v to the anodes through a crude rheostat and
>>> power resistor?
>>
>> Or buck smps down to 9.7 volts and an LM317 with resistor
>> current limiting for each, w/o overheating issues. LM317
>> thermal limits, protecting itself in case of shorts, etc.
>
> But it won't do the 3A top limit mentioned -
Oh, sorry (referring quickly to AoE Table 9.2), I meant
the LM350T (3A) or the LM338T (5A), in TO-220 packages.
Or if pressed, a few LM317 (1.5A) in parallel. Examine
the spec sheets to see if more than 9.7 volts is needed.
--
Thanks,
- Win
[toc] | [prev] | [next] | [standalone]
| From | Winfield Hill <hill@rowland.harvard.edu> |
|---|---|
| Date | 2017-05-03 17:22 -0700 |
| Message-ID | <oeds7c06v9@drn.newsguy.com> |
| In reply to | #458613 |
Winfield Hill wrote...
> Ian Field wrote...
>> Winfield Hill wrote...
>>> Martin Brown wrote...
>>>>
>>>> On 03/05/2017 13:15, Clifford Heath wrote:
>>>>> A friend works in concrete reinforcing corrosion remediation,
>>>>> and has been asked to take over a project that's underway
>>>>> despite not having been properly designed or specified. ...
>>>>
>>>> Why not use a high power switched mode DC to DC converter
>>>> to supply 8.5v to the anodes through a crude rheostat and
>>>> power resistor?
>>>
>>> Or buck smps down to 9.7 volts and an LM317 with resistor
>>> current limiting for each, w/o overheating issues. LM317
>>> thermal limits, protecting itself in case of shorts, etc.
>>
>> But it won't do the 3A top limit mentioned -
>
> Oh, sorry (referring quickly to AoE Table 9.2), I meant
> the LM350T (3A) or the LM338T (5A), in TO-220 packages.
> Or if pressed, a few LM317 (1.5A) in parallel. Examine
> the spec sheets to see if more than 9.7 volts is needed.
That's one (or a few) buck converter we're suggesting,
to be shared among CL circuits and stations.
--
Thanks,
- Win
[toc] | [prev] | [next] | [standalone]
| From | tabbypurr@gmail.com |
|---|---|
| Date | 2017-05-06 00:41 -0700 |
| Message-ID | <29b4b8f5-d527-4d22-926f-f1c00abb73b3@googlegroups.com> |
| In reply to | #458604 |
On Wednesday, 3 May 2017 19:43:42 UTC+1, Ian Field wrote: > "Winfield Hill" <hill@rowland.harvard.edu> wrote in message > news:oed67g0240p@drn.newsguy.com... > >> Why not use a high power switched mode DC to DC converter > >> to supply 8.5v to the anodes through a crude rheostat and > >> power resistor? > > > > Or buck smps down to 9.7 volts and an LM317 with resistor > > current limiting for each, w/o overheating issues. LM317 > > thermal limits, protecting itself in case of shorts, etc. > > But it won't do the 3A top limit mentioned - the 78xx appnotes show how to > increase current with an external bypass transistor, it should work with the > 317. > > There used to be a higher current adjustable in TO3 - no idea whether there > still is. Parallel 317s do the job with overheat protection - external pass lacks that unless you complicate things. NT
[toc] | [prev] | [next] | [standalone]
| From | "dcaster@krl.org" <dcaster@krl.org> |
|---|---|
| Date | 2017-05-03 06:15 -0700 |
| Message-ID | <cd905c52-821f-4447-9337-03f3f952629d@googlegroups.com> |
| In reply to | #458546 |
On Wednesday, May 3, 2017 at 8:15:42 AM UTC-4, Clifford Heath wrote:
> I was thinking of LM350T regulators, programmed with a power
> resistor in the range 0.6-10 ohms... but the 2degC/W heat sink
> for each one could be an issue (thinking 2A, 14.7V, shorted to
> earth; 30W).
>
> Is there any other off-the-shelf quick solution that comes to
> mind?
>
> Clifford Heath.
Have you looked for a pulse width modulated current regulator? That would be more efficient putting less heat into the regulator. And would also use less power from the batteries.
Microcontrolers are very cheap now and might be a cheap and reliable
way to adjust the current instead of having variable resistors.
Dan
[toc] | [prev] | [next] | [standalone]
| From | Spehro Pefhany <speffSNIP@interlogDOTyou.knowwhat> |
|---|---|
| Date | 2017-05-03 11:10 -0400 |
| Message-ID | <qesjgcdt79in73vmo3r46li0gp3u561cbs@4ax.com> |
| In reply to | #458546 |
On Wed, 3 May 2017 22:15:36 +1000, the renowned Clifford Heath <no.spam@please.net> wrote: >A friend works in concrete reinforcing corrosion remediation, >and has been asked to take over a project that's underway >despite not having been properly designed or specified. > >The contractors are installing 400 anodes into the structure, >and each one needs a specific amount of charge to be deposited >into it, all over a week or two. The resistance is unknown and >could change from day to day, but the voltage must not rise >above +9V, or the titanium wires rapidly corrode. So they >want to adjust the current for each anode, probably in the >range of 100ma to 3000mA. They're intending to feed the whole >protection thing from banks of 12V lead acid batteries, I >guess because it's a remote site. > >The initial thought was to walk around and measure the current >on each anode every day, and switch off any that have dumped >the required charge... but that's quite labour-intensive. > >So I was thinking about current regulators. What's the easiest >way of sourcing 400 adjustable DC current sources in a short time? > >I was thinking of LM350T regulators, programmed with a power >resistor in the range 0.6-10 ohms... but the 2degC/W heat sink >for each one could be an issue (thinking 2A, 14.7V, shorted to >earth; 30W). > >Is there any other off-the-shelf quick solution that comes to >mind? > >Clifford Heath. A voltage regulator with a crude adjustable current limit, plus a ammeter + charge meter/setpoint per anode. Could be with a micro easily, and relatively quickl depending on what 'quick' means. What's the idea if the total current is too large for the batteries? Go around and turn a few hundred knobs? Seems like a hassle. --sp -- Best regards, Spehro Pefhany
[toc] | [prev] | [next] | [standalone]
| From | Tim Wescott <tim@seemywebsite.com> |
|---|---|
| Date | 2017-05-03 11:27 -0500 |
| Message-ID | <5Mydnddrq4l6mZfEnZ2dnUU7-LmdnZ2d@giganews.com> |
| In reply to | #458546 |
On Wed, 03 May 2017 22:15:36 +1000, Clifford Heath wrote: > A friend works in concrete reinforcing corrosion remediation, > and has been asked to take over a project that's underway despite not > having been properly designed or specified. > > The contractors are installing 400 anodes into the structure, > and each one needs a specific amount of charge to be deposited into it, > all over a week or two. The resistance is unknown and could change from > day to day, but the voltage must not rise above +9V, or the titanium > wires rapidly corrode. So they want to adjust the current for each > anode, probably in the range of 100ma to 3000mA. They're intending to > feed the whole protection thing from banks of 12V lead acid batteries, I > guess because it's a remote site. > > The initial thought was to walk around and measure the current on each > anode every day, and switch off any that have dumped the required > charge... but that's quite labour-intensive. > > So I was thinking about current regulators. What's the easiest way of > sourcing 400 adjustable DC current sources in a short time? > > I was thinking of LM350T regulators, programmed with a power resistor in > the range 0.6-10 ohms... but the 2degC/W heat sink for each one could be > an issue (thinking 2A, 14.7V, shorted to earth; 30W). > > Is there any other off-the-shelf quick solution that comes to mind? > > Clifford Heath. You gonna make circuit boards, or just hand-wire, or what? How about a good old LM723 with a honkin' big pass transistor? You should be able to make a nice constant-current supply with voltage limiting. You should be able to do the same thing with switchers, but the design time would be longer -- the all-linear way just means you need big heat sinks. Surely if this is a known procedure then there must be products to do it. -- Tim Wescott Control systems, embedded software and circuit design I'm looking for work! See my website if you're interested http://www.wescottdesign.com
[toc] | [prev] | [next] | [standalone]
| From | "Ian Field" <gangprobing.alien1@virginmedia.com> |
|---|---|
| Date | 2017-05-03 19:47 +0100 |
| Message-ID | <6BpOA.619240$987.593644@fx20.am4> |
| In reply to | #458577 |
"Tim Wescott" <tim@seemywebsite.com> wrote in message news:5Mydnddrq4l6mZfEnZ2dnUU7-LmdnZ2d@giganews.com... > On Wed, 03 May 2017 22:15:36 +1000, Clifford Heath wrote: > >> A friend works in concrete reinforcing corrosion remediation, >> and has been asked to take over a project that's underway despite not >> having been properly designed or specified. >> >> The contractors are installing 400 anodes into the structure, >> and each one needs a specific amount of charge to be deposited into it, >> all over a week or two. The resistance is unknown and could change from >> day to day, but the voltage must not rise above +9V, or the titanium >> wires rapidly corrode. So they want to adjust the current for each >> anode, probably in the range of 100ma to 3000mA. They're intending to >> feed the whole protection thing from banks of 12V lead acid batteries, I >> guess because it's a remote site. >> >> The initial thought was to walk around and measure the current on each >> anode every day, and switch off any that have dumped the required >> charge... but that's quite labour-intensive. >> >> So I was thinking about current regulators. What's the easiest way of >> sourcing 400 adjustable DC current sources in a short time? >> >> I was thinking of LM350T regulators, programmed with a power resistor in >> the range 0.6-10 ohms... but the 2degC/W heat sink for each one could be >> an issue (thinking 2A, 14.7V, shorted to earth; 30W). >> >> Is there any other off-the-shelf quick solution that comes to mind? >> >> Clifford Heath. > > You gonna make circuit boards, or just hand-wire, or what? > > How about a good old LM723 with a honkin' big pass transistor? You > should be able to make a nice constant-current supply with voltage > limiting. > > You should be able to do the same thing with switchers, but the design > time would be longer -- the all-linear way just means you need big heat > sinks. > > Surely if this is a known procedure then there must be products to do it. Could be a bodge - they used to mix lime in the concrete to make it set faster, but it eats the steel reinforcements - there were some spectacular disasters hit the news.
[toc] | [prev] | [next] | [standalone]
| From | Clifford Heath <no.spam@please.net> |
|---|---|
| Date | 2017-05-04 12:41 +1000 |
| Message-ID | <590a94db$0$53186$c3e8da3$fdf4f6af@news.astraweb.com> |
| In reply to | #458605 |
On 04/05/17 04:47, Ian Field wrote: > "Tim Wescott" <tim@seemywebsite.com> wrote in message > news:5Mydnddrq4l6mZfEnZ2dnUU7-LmdnZ2d@giganews.com... >> On Wed, 03 May 2017 22:15:36 +1000, Clifford Heath wrote: >> >>> A friend works in concrete reinforcing corrosion remediation, >>> and has been asked to take over a project that's underway despite not >>> having been properly designed or specified. >>> >>> The contractors are installing 400 anodes into the structure, >>> and each one needs a specific amount of charge to be deposited into it, >> Surely if this is a known procedure then there must be products to do it. There are, but usually in the context of also installing long-term monitoring equipment (e.g. in an old skyscraper with concrete cancer). This is new work that won't be monitored continuously. > Could be a bodge - they used to mix lime in the concrete to make it set > faster, but it eats the steel reinforcements - there were some > spectacular disasters hit the news. Not sure about that Ian - it's the high pH of concrete that protects the steel. Concrete cancer results when water leaches the pH down from 13-ish to about 8.5, esp. when chloride is present (e.g. marine air). More lime should help protect the steel, but the most important things are to (a) stop the rusting process, (b) passivate existing rust and (c) prevent water and chloride ingress with appropriate coatings. If you haven't done that, that's when you need to call in the experts to passivate, seal and monitor the rusted steel. Clifford Heath.
[toc] | [prev] | [next] | [standalone]
| From | "Ian Field" <gangprobing.alien1@virginmedia.com> |
|---|---|
| Date | 2017-05-04 20:55 +0100 |
| Message-ID | <iGLOA.1036093$0k4.345160@fx37.am4> |
| In reply to | #458644 |
"Clifford Heath" <no.spam@please.net> wrote in message news:590a94db$0$53186$c3e8da3$fdf4f6af@news.astraweb.com... > On 04/05/17 04:47, Ian Field wrote: >> "Tim Wescott" <tim@seemywebsite.com> wrote in message >> news:5Mydnddrq4l6mZfEnZ2dnUU7-LmdnZ2d@giganews.com... >>> On Wed, 03 May 2017 22:15:36 +1000, Clifford Heath wrote: >>> >>>> A friend works in concrete reinforcing corrosion remediation, >>>> and has been asked to take over a project that's underway despite not >>>> having been properly designed or specified. >>>> >>>> The contractors are installing 400 anodes into the structure, >>>> and each one needs a specific amount of charge to be deposited into it, > >>> Surely if this is a known procedure then there must be products to do >>> it. > > There are, but usually in the context of also installing long-term > monitoring equipment (e.g. in an old skyscraper with concrete cancer). > This is new work that won't be monitored continuously. > >> Could be a bodge - they used to mix lime in the concrete to make it set >> faster, but it eats the steel reinforcements - there were some >> spectacular disasters hit the news. > > Not sure about that Ian - it's the high pH of concrete that protects > the steel. Concrete cancer results when water leaches the pH down > from 13-ish to about 8.5, esp. when chloride is present (e.g. marine > air). More lime should help protect the steel, but the most important > things are to (a) stop the rusting process, (b) passivate existing > rust and (c) prevent water and chloride ingress with appropriate > coatings. If you haven't done that, that's when you need to call in > the experts to passivate, seal and monitor the rusted steel. The rust is pretty difficult to get at until it starts to expand to the point where chunks of concrete drop off.
[toc] | [prev] | [next] | [standalone]
| From | Clifford Heath <no.spam@please.net> |
|---|---|
| Date | 2017-05-05 08:39 +1000 |
| Message-ID | <590bad89$0$42049$c3e8da3$3a1a2348@news.astraweb.com> |
| In reply to | #458781 |
On 05/05/17 05:55, Ian Field wrote: > > > "Clifford Heath" <no.spam@please.net> wrote in message > news:590a94db$0$53186$c3e8da3$fdf4f6af@news.astraweb.com... >> On 04/05/17 04:47, Ian Field wrote: >>> "Tim Wescott" <tim@seemywebsite.com> wrote in message >>> news:5Mydnddrq4l6mZfEnZ2dnUU7-LmdnZ2d@giganews.com... >>>> On Wed, 03 May 2017 22:15:36 +1000, Clifford Heath wrote: >>>> >>>>> A friend works in concrete reinforcing corrosion remediation, >>>>> and has been asked to take over a project that's underway despite not >>>>> having been properly designed or specified. >>>>> >>>>> The contractors are installing 400 anodes into the structure, >>>>> and each one needs a specific amount of charge to be deposited into >>>>> it, >> >>>> Surely if this is a known procedure then there must be products to >>>> do it. >> >> There are, but usually in the context of also installing long-term >> monitoring equipment (e.g. in an old skyscraper with concrete cancer). >> This is new work that won't be monitored continuously. >> >>> Could be a bodge - they used to mix lime in the concrete to make it set >>> faster, but it eats the steel reinforcements - there were some >>> spectacular disasters hit the news. >> >> Not sure about that Ian - it's the high pH of concrete that protects >> the steel. Concrete cancer results when water leaches the pH down >> from 13-ish to about 8.5, esp. when chloride is present (e.g. marine >> air). More lime should help protect the steel, but the most important >> things are to (a) stop the rusting process, (b) passivate existing >> rust and (c) prevent water and chloride ingress with appropriate >> coatings. If you haven't done that, that's when you need to call in >> the experts to passivate, seal and monitor the rusted steel. > > The rust is pretty difficult to get at until it starts to expand to the > point where chunks of concrete drop off. I guess that's why these people have a business. They can passivate that rust electrolytically. It does involve some fancy gear to find the reinforcing and ensure it's all electrically connected, without demolishing the entire structure. After treatment with the impressed current, it still needs some cathodic protection, but that's as often galvanic (zinc anodes, etc) than powered. If powered, it's monitored.
[toc] | [prev] | [next] | [standalone]
| From | "dcaster@krl.org" <dcaster@krl.org> |
|---|---|
| Date | 2017-05-03 09:37 -0700 |
| Message-ID | <df0c5b0d-a1a2-4aa2-af73-9870a4387ca8@googlegroups.com> |
| In reply to | #458546 |
On Wednesday, May 3, 2017 at 8:15:42 AM UTC-4, Clifford Heath wrote:
> The contractors are installing 400 anodes into the structure,
> and each one needs a specific amount of charge to be deposited
> into it, all over a week or two. The resistance is unknown and
> could change from day to day, but the voltage must not rise
> above +9V, or the titanium wires rapidly corrode. So they
> want to adjust the current for each anode, probably in the
> range of 100ma to 3000mA. They're intending to feed the whole
> protection thing from banks of 12V lead acid batteries, I
> guess because it's a remote site.
>
> Is there any other off-the-shelf quick solution that comes to
> mind?
>
> Clifford Heath.
Not sure I really understand the problem. But would tend toward using a micro controler and have the mirco controler figure out what the current needs to be.
I would expect that any system for corrosion prevention is going to be used for a long time. The first person who sets the current will probably do a good job. But after several changes in personel. you might run into someone that does not understand all the reasoning.
It also sounds as if using a solar panel to charge the batteries might also be the economic thing to do. Hauling batteries around to get charged takes labor.
Dan
[toc] | [prev] | [next] | [standalone]
| From | Tim Wescott <seemywebsite@myfooter.really> |
|---|---|
| Date | 2017-05-03 13:53 -0500 |
| Message-ID | <xLadnWYZ47qSupfEnZ2dnUU7-budnZ2d@giganews.com> |
| In reply to | #458546 |
On Wed, 03 May 2017 22:15:36 +1000, Clifford Heath wrote: > A friend works in concrete reinforcing corrosion remediation, > and has been asked to take over a project that's underway despite not > having been properly designed or specified. > > The contractors are installing 400 anodes into the structure, > and each one needs a specific amount of charge to be deposited into it, > all over a week or two. The resistance is unknown and could change from > day to day, but the voltage must not rise above +9V, or the titanium > wires rapidly corrode. So they want to adjust the current for each > anode, probably in the range of 100ma to 3000mA. They're intending to > feed the whole protection thing from banks of 12V lead acid batteries, I > guess because it's a remote site. > > The initial thought was to walk around and measure the current on each > anode every day, and switch off any that have dumped the required > charge... but that's quite labour-intensive. > > So I was thinking about current regulators. What's the easiest way of > sourcing 400 adjustable DC current sources in a short time? > > I was thinking of LM350T regulators, programmed with a power resistor in > the range 0.6-10 ohms... but the 2degC/W heat sink for each one could be > an issue (thinking 2A, 14.7V, shorted to earth; 30W). > > Is there any other off-the-shelf quick solution that comes to mind? > > Clifford Heath. Go eBay shopping. No guarantees, but this was the top result in my third search: <http://www.ebay.com/itm/DC-DC-Buck-Converter-Constant-Current-Voltage- Adjustable-Module-Regulator-0-1-3A-/371904719117? hash=item56973fa90d:g:EQYAAOSwSlBY2cTv> -- Tim Wescott Wescott Design Services http://www.wescottdesign.com I'm looking for work -- see my website!
[toc] | [prev] | [next] | [standalone]
| From | Clifford Heath <no.spam@please.net> |
|---|---|
| Date | 2017-05-04 12:24 +1000 |
| Message-ID | <590a90dc$0$40452$c3e8da3$b280bf18@news.astraweb.com> |
| In reply to | #458608 |
On 04/05/17 04:53, Tim Wescott wrote: > On Wed, 03 May 2017 22:15:36 +1000, Clifford Heath wrote: > >> A friend works in concrete reinforcing corrosion remediation, >> and has been asked to take over a project that's underway despite not >> having been properly designed or specified. >> >> The contractors are installing 400 anodes into the structure, >> and each one needs a specific amount of charge to be deposited into it, >> all over a week or two. The resistance is unknown and could change from >> day to day, but the voltage must not rise above +9V, or the titanium >> wires rapidly corrode. So they want to adjust the current for each >> anode, probably in the range of 100ma to 3000mA. They're intending to >> feed the whole protection thing from banks of 12V lead acid batteries, I >> guess because it's a remote site. >> >> The initial thought was to walk around and measure the current on each >> anode every day, and switch off any that have dumped the required >> charge... but that's quite labour-intensive. >> >> So I was thinking about current regulators. What's the easiest way of >> sourcing 400 adjustable DC current sources in a short time? >> >> I was thinking of LM350T regulators, programmed with a power resistor in >> the range 0.6-10 ohms... but the 2degC/W heat sink for each one could be >> an issue (thinking 2A, 14.7V, shorted to earth; 30W). >> >> Is there any other off-the-shelf quick solution that comes to mind? >> >> Clifford Heath. > > Go eBay shopping. No guarantees, but this was the top result in my third > search: > > <http://www.ebay.com/itm/DC-DC-Buck-Converter-Constant-Current-Voltage- > Adjustable-Module-Regulator-0-1-3A-/371904719117? > hash=item56973fa90d:g:EQYAAOSwSlBY2cTv> This looks like a winner, 12 units delivered by DHL for under $AU100: <https://www.aliexpress.com/item/5A-Adjustable-CC-CV-Display-Step-Down-charge-Module-LED-Panel-Voltmeter-Ammeter/32670081212.html>. The electricians can be told to set the voltage limit to 9V (output open circuit), then connect the output and set the current to the specified level. The connectors are a bit flimsy, might be best to wire them to external connectors on the waterproof case, even though wires will enter through a gland. I got more detail on the problem. The 400 anodes are being installed in a sea wall during its construction, and each one needs a calculated charge (depending on its location) to be dumped into it, once only, over about a week's duration. Only about 10 will be active at a time, so the units and the batteries will be moved along as the wall is being built. They'll be moved each week or so, but the regulators mean they don't need to be visited every day and unhooked for monitoring. I don't know more about the chemistry (that's his domain) but the prevalence of chloride is the main factor. I suspect that the treatment passivates metal surfaces that were exposed during construction but are now encased in protective concrete (high pH). The time factor is because the job has commenced before the previous project manager (now departed, not sure if ignominiously) figured out how to run the passivation procedure. The treatments would ideally have started last week, so there's no time to design a new regulator. There's also no mains power available. Clifford Heath.
[toc] | [prev] | [next] | [standalone]