Groups | Search | Server Info | Keyboard shortcuts | Login | Register [http] [https] [nntp] [nntps]


Groups > linux.kernel > #1576283 > unrolled thread

[PATCH] thermal: mt8173: minor mtk_thermal.c cleanups

Started byDawei Chien <dawei.chien@mediatek.com>
First post2017-02-08 06:40 +0100
Last post2017-02-13 10:10 +0100
Articles 3 — 2 participants

Back to article view | Back to linux.kernel


Contents

  [PATCH] thermal: mt8173: minor mtk_thermal.c cleanups Dawei Chien <dawei.chien@mediatek.com> - 2017-02-08 06:40 +0100
    Re: [PATCH] thermal: mt8173: minor mtk_thermal.c cleanups Matthias Brugger <matthias.bgg@gmail.com> - 2017-02-09 22:30 +0100
      Re: [PATCH] thermal: mt8173: minor mtk_thermal.c cleanups Dawei Chien <dawei.chien@mediatek.com> - 2017-02-13 10:10 +0100

#1576283 — [PATCH] thermal: mt8173: minor mtk_thermal.c cleanups

FromDawei Chien <dawei.chien@mediatek.com>
Date2017-02-08 06:40 +0100
Subject[PATCH] thermal: mt8173: minor mtk_thermal.c cleanups
Message-ID<t8t90-4vJ-3@gated-at.bofh.it>
Thermal driver should read TEMP_MSR3 if thermal bank with 4 sensors.
However, Currently thermal driver don't need read TEMP_MSR3 since
thermal controller only use 3 sensors for each thermal bank.

Signed-off-by: Dawei Chien <dawei.chien@mediatek.com>
---
 drivers/thermal/mtk_thermal.c | 2 +-
 1 file changed, 1 insertion(+), 1 deletion(-)

diff --git a/drivers/thermal/mtk_thermal.c b/drivers/thermal/mtk_thermal.c
index 34169c3..c124151 100644
--- a/drivers/thermal/mtk_thermal.c
+++ b/drivers/thermal/mtk_thermal.c
@@ -191,7 +191,7 @@ struct mtk_thermal {
 };
 
 const int mt8173_msr[MT8173_NUM_SENSORS_PER_ZONE] = {
-	TEMP_MSR0, TEMP_MSR1, TEMP_MSR2, TEMP_MSR2
+	TEMP_MSR0, TEMP_MSR1, TEMP_MSR2, TEMP_MSR3
 };
 
 const int mt8173_adcpnp[MT8173_NUM_SENSORS_PER_ZONE] = {
-- 
1.9.1

[toc] | [next] | [standalone]


#1577967

FromMatthias Brugger <matthias.bgg@gmail.com>
Date2017-02-09 22:30 +0100
Message-ID<t94rT-2U0-19@gated-at.bofh.it>
In reply to#1576283

On 02/08/2017 06:31 AM, Dawei Chien wrote:
> Thermal driver should read TEMP_MSR3 if thermal bank with 4 sensors.
> However, Currently thermal driver don't need read TEMP_MSR3 since
> thermal controller only use 3 sensors for each thermal bank.
>
> Signed-off-by: Dawei Chien <dawei.chien@mediatek.com>
> ---

Actually the commit message should state:
Fixes: b7cf0053738c ("thermal: Add Mediatek thermal driver for mt2701.")

...and get backported to v4.9 and v4.10.

Reviewed-by: Matthias Brugger <matthias.bgg@gmail.com>

Regards,
Matthias

>  drivers/thermal/mtk_thermal.c | 2 +-
>  1 file changed, 1 insertion(+), 1 deletion(-)
>
> diff --git a/drivers/thermal/mtk_thermal.c b/drivers/thermal/mtk_thermal.c
> index 34169c3..c124151 100644
> --- a/drivers/thermal/mtk_thermal.c
> +++ b/drivers/thermal/mtk_thermal.c
> @@ -191,7 +191,7 @@ struct mtk_thermal {
>  };
>
>  const int mt8173_msr[MT8173_NUM_SENSORS_PER_ZONE] = {
> -	TEMP_MSR0, TEMP_MSR1, TEMP_MSR2, TEMP_MSR2
> +	TEMP_MSR0, TEMP_MSR1, TEMP_MSR2, TEMP_MSR3
>  };
>
>  const int mt8173_adcpnp[MT8173_NUM_SENSORS_PER_ZONE] = {
>

[toc] | [prev] | [next] | [standalone]


#1579536

FromDawei Chien <dawei.chien@mediatek.com>
Date2017-02-13 10:10 +0100
Message-ID<takNX-1Fl-5@gated-at.bofh.it>
In reply to#1577967
Hi, Matthias,

On Thu, 2017-02-09 at 22:25 +0100, Matthias Brugger wrote:
> 
> On 02/08/2017 06:31 AM, Dawei Chien wrote:
> > Thermal driver should read TEMP_MSR3 if thermal bank with 4 sensors.
> > However, Currently thermal driver don't need read TEMP_MSR3 since
> > thermal controller only use 3 sensors for each thermal bank.
> >
> > Signed-off-by: Dawei Chien <dawei.chien@mediatek.com>
> > ---
> 
> Actually the commit message should state:
> Fixes: b7cf0053738c ("thermal: Add Mediatek thermal driver for mt2701.")
> 
> ...and get backported to v4.9 and v4.10.
> 
> Reviewed-by: Matthias Brugger <matthias.bgg@gmail.com>
> 
> Regards,
> Matthias

Thank you for your review. I would add below commit message on next
version. However, currently 8173 thermal driver would not read TEMP_MSR3
since thermal driver only use 3 sensors on each bank, this patch would
not effect temperature.
Only if thermal driver use 4 sensors on any thermal bank, would read
third sensor two times, and lose fourth sensor of vale.
Fixes: b7cf0053738c ("thermal: Add Mediatek thermal driver for mt2701.")

> >  drivers/thermal/mtk_thermal.c | 2 +-
> >  1 file changed, 1 insertion(+), 1 deletion(-)
> >
> > diff --git a/drivers/thermal/mtk_thermal.c b/drivers/thermal/mtk_thermal.c
> > index 34169c3..c124151 100644
> > --- a/drivers/thermal/mtk_thermal.c
> > +++ b/drivers/thermal/mtk_thermal.c
> > @@ -191,7 +191,7 @@ struct mtk_thermal {
> >  };
> >
> >  const int mt8173_msr[MT8173_NUM_SENSORS_PER_ZONE] = {
> > -	TEMP_MSR0, TEMP_MSR1, TEMP_MSR2, TEMP_MSR2
> > +	TEMP_MSR0, TEMP_MSR1, TEMP_MSR2, TEMP_MSR3
> >  };
> >
> >  const int mt8173_adcpnp[MT8173_NUM_SENSORS_PER_ZONE] = {
> >

[toc] | [prev] | [standalone]