Groups | Search | Server Info | Keyboard shortcuts | Login | Register [http] [https] [nntp] [nntps]
Groups > linux.kernel > #1563324 > unrolled thread
| Started by | Thierry Reding <thierry.reding@gmail.com> |
|---|---|
| First post | 2017-01-20 07:50 +0100 |
| Last post | 2017-01-20 07:50 +0100 |
| Articles | 1 — 1 participant |
Back to article view | Back to linux.kernel
This discussion starts older than the indexed window; earlier articles aren't shown. The article labeled Started by
below is the oldest one visible, not the original post.
Re: [PATCH 1/2] pwm: pca9685: fix period change with same duty cycle Thierry Reding <thierry.reding@gmail.com> - 2017-01-20 07:50 +0100
| From | Thierry Reding <thierry.reding@gmail.com> |
|---|---|
| Date | 2017-01-20 07:50 +0100 |
| Subject | Re: [PATCH 1/2] pwm: pca9685: fix period change with same duty cycle |
| Message-ID | <t1Bbk-3QV-7@gated-at.bofh.it> |
[Multipart message — attachments visible in raw view] — view raw
On Tue, Dec 13, 2016 at 04:52:50PM +0100, Clemens Gruber wrote:
> When first implementing support for changing the output frequency, an
> optimization was added to continue the PWM after changing the prescaler
> without having to reprogram the ON and OFF registers for the duty cycle,
> in case the duty cycle stayed the same.
> This was flawed, because we compared the absolute value of the duty
> cycle in nanoseconds instead of the ratio to the period.
>
> Fix the problem by removing the shortcut.
>
> Fixes: 01ec8472009c9 ("pwm-pca9685: Support changing the output
> frequency")
> Cc: <stable@vger.kernel.org> # v4.3+
> Signed-off-by: Clemens Gruber <clemens.gruber@pqgruber.com>
> ---
> drivers/pwm/pwm-pca9685.c | 11 -----------
> 1 file changed, 11 deletions(-)
Applied, thanks.
Thierry