Groups | Search | Server Info | Keyboard shortcuts | Login | Register [http] [https] [nntp] [nntps]
Groups > linux.kernel > #1166398 > unrolled thread
| Started by | Peter Meerwald <pmeerw@pmeerw.net> |
|---|---|
| First post | 2015-06-16 22:50 +0200 |
| Last post | 2015-06-16 22:50 +0200 |
| Articles | 1 — 1 participant |
Back to article view | Back to linux.kernel
This discussion starts older than the indexed window; earlier articles aren't shown. The article labeled Started by
below is the oldest one visible, not the original post.
Re: [PATCH 1/2] iio: ABI: Clarify proximity output value Peter Meerwald <pmeerw@pmeerw.net> - 2015-06-16 22:50 +0200
| From | Peter Meerwald <pmeerw@pmeerw.net> |
|---|---|
| Date | 2015-06-16 22:50 +0200 |
| Subject | Re: [PATCH 1/2] iio: ABI: Clarify proximity output value |
| Message-ID | <pC5XY-5b9-15@gated-at.bofh.it> |
Hello,
> Current description for proximity measurement is ambiguous. While
> the first part says that proximity is measured by observing
> reflectivity, the second part incorrectly infers that reported values
> should behave like a distance.
>
> This is because of AS3935 lightning sensor which uses the proximity
> API, while not being a true proximity sensor.
Acked-by: Peter Meerwald <pmeerw@pmeerw.net>
> Fixes: 614e8842ddf ("iio: ABI: add clarification for proximity")
> Signed-off-by: Daniel Baluta <daniel.baluta@intel.com>
> ---
> Documentation/ABI/testing/sysfs-bus-iio | 6 ++----
> 1 file changed, 2 insertions(+), 4 deletions(-)
>
> diff --git a/Documentation/ABI/testing/sysfs-bus-iio b/Documentation/ABI/testing/sysfs-bus-iio
> index bbed111..70c9b1a 100644
> --- a/Documentation/ABI/testing/sysfs-bus-iio
> +++ b/Documentation/ABI/testing/sysfs-bus-iio
> @@ -1234,10 +1234,8 @@ Description:
> object is near the sensor, usually be observing
> reflectivity of infrared or ultrasound emitted.
> Often these sensors are unit less and as such conversion
> - to SI units is not possible. Where it is, the units should
> - be meters. If such a conversion is not possible, the reported
> - values should behave in the same way as a distance, i.e. lower
> - values indicate something is closer to the sensor.
> + to SI units is not possible. Higher proximity measurements
> + indicate closer objects, and vice versa.
>
> What: /sys/.../iio:deviceX/in_illuminance_input
> What: /sys/.../iio:deviceX/in_illuminance_raw
>
--
Peter Meerwald
+43-664-2444418 (mobile)
--
To unsubscribe from this list: send the line "unsubscribe linux-kernel" in
the body of a message to majordomo@vger.kernel.org
More majordomo info at http://vger.kernel.org/majordomo-info.html
Please read the FAQ at http://www.tux.org/lkml/
Back to top | Article view | linux.kernel