Groups | Search | Server Info | Keyboard shortcuts | Login | Register [http] [https] [nntp] [nntps]


Groups > linux.kernel > #1166398 > unrolled thread

Re: [PATCH 1/2] iio: ABI: Clarify proximity output value

Started byPeter Meerwald <pmeerw@pmeerw.net>
First post2015-06-16 22:50 +0200
Last post2015-06-16 22:50 +0200
Articles 1 — 1 participant

Back to article view | Back to linux.kernel

This discussion starts older than the indexed window; earlier articles aren't shown. The article labeled Started by below is the oldest one visible, not the original post.


Contents

  Re: [PATCH 1/2] iio: ABI: Clarify proximity output value Peter Meerwald <pmeerw@pmeerw.net> - 2015-06-16 22:50 +0200

#1166398 — Re: [PATCH 1/2] iio: ABI: Clarify proximity output value

FromPeter Meerwald <pmeerw@pmeerw.net>
Date2015-06-16 22:50 +0200
SubjectRe: [PATCH 1/2] iio: ABI: Clarify proximity output value
Message-ID<pC5XY-5b9-15@gated-at.bofh.it>
Hello,

> Current description for proximity measurement is ambiguous. While
> the first part says that proximity is measured by observing
> reflectivity, the second part incorrectly infers that reported values
> should behave like a distance.
> 
> This is because of AS3935 lightning sensor which uses the proximity
> API, while not being a true proximity sensor.

Acked-by: Peter Meerwald <pmeerw@pmeerw.net>
 
> Fixes:  614e8842ddf ("iio: ABI: add clarification for proximity")
> Signed-off-by: Daniel Baluta <daniel.baluta@intel.com>
> ---
>  Documentation/ABI/testing/sysfs-bus-iio | 6 ++----
>  1 file changed, 2 insertions(+), 4 deletions(-)
> 
> diff --git a/Documentation/ABI/testing/sysfs-bus-iio b/Documentation/ABI/testing/sysfs-bus-iio
> index bbed111..70c9b1a 100644
> --- a/Documentation/ABI/testing/sysfs-bus-iio
> +++ b/Documentation/ABI/testing/sysfs-bus-iio
> @@ -1234,10 +1234,8 @@ Description:
>  		object is near the sensor, usually be observing

>  		reflectivity of infrared or ultrasound emitted.
>  		Often these sensors are unit less and as such conversion
> -		to SI units is not possible.  Where it is, the units should
> -		be meters.  If such a conversion is not possible, the reported
> -		values should behave in the same way as a distance, i.e. lower
> -		values indicate something is closer to the sensor.
> +		to SI units is not possible. Higher proximity measurements
> +		indicate closer objects, and vice versa.
>  
>  What:		/sys/.../iio:deviceX/in_illuminance_input
>  What:		/sys/.../iio:deviceX/in_illuminance_raw
> 

-- 

Peter Meerwald
+43-664-2444418 (mobile)
--
To unsubscribe from this list: send the line "unsubscribe linux-kernel" in
the body of a message to majordomo@vger.kernel.org