Groups | Search | Server Info | Keyboard shortcuts | Login | Register [http] [https] [nntp] [nntps]


Groups > linux.kernel > #1717579

[PATCH 4/5] perf script: support physical addresses

From kan.liang@intel.com
Newsgroups linux.kernel
Subject [PATCH 4/5] perf script: support physical addresses
Date 2017-08-22 18:50 +0200
Message-ID <uhkxk-4Zc-9@gated-at.bofh.it> (permalink)
References <uhkxj-4Zc-5@gated-at.bofh.it>
Organization linux.* mail to news gateway

Show all headers | View raw


From: Kan Liang <kan.liang@intel.com>

perf script print out physical addresses if phys_addr is applied in perf
record.
Only display physical address when virtual address is selected.

Signed-off-by: Kan Liang <kan.liang@intel.com>
---
 tools/perf/Documentation/perf-script.txt |  2 +-
 tools/perf/builtin-script.c              | 21 +++++++++++++++++++--
 2 files changed, 20 insertions(+), 3 deletions(-)

diff --git a/tools/perf/Documentation/perf-script.txt b/tools/perf/Documentation/perf-script.txt
index 5ee8796..18dfcfa 100644
--- a/tools/perf/Documentation/perf-script.txt
+++ b/tools/perf/Documentation/perf-script.txt
@@ -117,7 +117,7 @@ OPTIONS
         Comma separated list of fields to print. Options are:
         comm, tid, pid, time, cpu, event, trace, ip, sym, dso, addr, symoff,
         srcline, period, iregs, brstack, brstacksym, flags, bpf-output, brstackinsn, brstackoff,
-        callindent, insn, insnlen, synth.
+        callindent, insn, insnlen, synth, phys_addr.
         Field list can be prepended with the type, trace, sw or hw,
         to indicate to which event type the field list applies.
         e.g., -F sw:comm,tid,time,ip,sym  and -F trace:time,cpu,trace
diff --git a/tools/perf/builtin-script.c b/tools/perf/builtin-script.c
index 378f76c..4522138 100644
--- a/tools/perf/builtin-script.c
+++ b/tools/perf/builtin-script.c
@@ -87,6 +87,7 @@ enum perf_output_field {
 	PERF_OUTPUT_BRSTACKINSN	    = 1U << 23,
 	PERF_OUTPUT_BRSTACKOFF	    = 1U << 24,
 	PERF_OUTPUT_SYNTH           = 1U << 25,
+	PERF_OUTPUT_PHYS_ADDR       = 1U << 26,
 };
 
 struct output_option {
@@ -119,6 +120,7 @@ struct output_option {
 	{.str = "brstackinsn", .field = PERF_OUTPUT_BRSTACKINSN},
 	{.str = "brstackoff", .field = PERF_OUTPUT_BRSTACKOFF},
 	{.str = "synth", .field = PERF_OUTPUT_SYNTH},
+	{.str = "phys_addr", .field = PERF_OUTPUT_PHYS_ADDR},
 };
 
 enum {
@@ -175,7 +177,8 @@ static struct {
 			      PERF_OUTPUT_EVNAME | PERF_OUTPUT_IP |
 			      PERF_OUTPUT_SYM | PERF_OUTPUT_DSO |
 			      PERF_OUTPUT_PERIOD |  PERF_OUTPUT_ADDR |
-			      PERF_OUTPUT_DATA_SRC | PERF_OUTPUT_WEIGHT,
+			      PERF_OUTPUT_DATA_SRC | PERF_OUTPUT_WEIGHT |
+			      PERF_OUTPUT_PHYS_ADDR,
 
 		.invalid_fields = PERF_OUTPUT_TRACE | PERF_OUTPUT_BPF_OUTPUT,
 	},
@@ -328,6 +331,12 @@ static int perf_evsel__check_attr(struct perf_evsel *evsel,
 					PERF_OUTPUT_WEIGHT))
 		return -EINVAL;
 
+	if (PRINT_FIELD(PHYS_ADDR) && !PRINT_FIELD(ADDR)) {
+		pr_err("Display of sample physical address"
+		       "but sample address is not selected.\n");
+		return -EINVAL;
+	}
+
 	if (PRINT_FIELD(SYM) && !PRINT_FIELD(IP) && !PRINT_FIELD(ADDR)) {
 		pr_err("Display of symbols requested but neither sample IP nor "
 			   "sample address\nis selected. Hence, no addresses to convert "
@@ -382,6 +391,11 @@ static int perf_evsel__check_attr(struct perf_evsel *evsel,
 					PERF_OUTPUT_IREGS))
 		return -EINVAL;
 
+	if (PRINT_FIELD(PHYS_ADDR) &&
+		perf_evsel__do_check_stype(evsel, PERF_SAMPLE_PHYS_ADDR, "PHYS_ADDR",
+					   PERF_OUTPUT_PHYS_ADDR, allow_user_set))
+		return -EINVAL;
+
 	return 0;
 }
 
@@ -1446,6 +1460,9 @@ static void process_event(struct perf_script *script,
 	if (perf_evsel__is_bpf_output(evsel) && PRINT_FIELD(BPF_OUTPUT))
 		print_sample_bpf_output(sample);
 	print_insn(sample, attr, thread, machine);
+
+	if (PRINT_FIELD(PHYS_ADDR))
+		printf("%16" PRIx64, sample->phys_addr);
 	printf("\n");
 }
 
@@ -2729,7 +2746,7 @@ int cmd_script(int argc, const char **argv)
 		     "Valid types: hw,sw,trace,raw,synth. "
 		     "Fields: comm,tid,pid,time,cpu,event,trace,ip,sym,dso,"
 		     "addr,symoff,period,iregs,brstack,brstacksym,flags,"
-		     "bpf-output,callindent,insn,insnlen,brstackinsn,synth",
+		     "bpf-output,callindent,insn,insnlen,brstackinsn,synth,phys_addr",
 		     parse_output_fields),
 	OPT_BOOLEAN('a', "all-cpus", &system_wide,
 		    "system-wide collection from all CPUs"),
-- 
2.4.3

Back to linux.kernel | Previous | Next — Previous in thread | Find similar | Unroll thread


Thread

[PATCH 0/5] support PERF_SAMPLE_PHYS_ADDR (user) kan.liang@intel.com - 2017-08-22 18:50 +0200
  [PATCH 3/5] perf mem: support physical address kan.liang@intel.com - 2017-08-22 18:50 +0200
  [PATCH 2/5] perf tools: add sort option phys_daddr kan.liang@intel.com - 2017-08-22 18:50 +0200
  [PATCH 4/5] perf script: support physical addresses kan.liang@intel.com - 2017-08-22 18:50 +0200

csiph-web