Groups | Search | Server Info | Keyboard shortcuts | Login | Register [http] [https] [nntp] [nntps]
Groups > linux.kernel > #1584639
| From | Javier Martinez Canillas <javier@osg.samsung.com> |
|---|---|
| Newsgroups | linux.kernel |
| Subject | Re: [PATCH v2 1/3] arm64: dts: exynos: Add missing unit name to Exynos7 SoC node |
| Date | 2017-02-20 15:10 +0100 |
| Message-ID | <tcWP8-5GV-17@gated-at.bofh.it> (permalink) |
| References | <sY8yS-4e0-43@gated-at.bofh.it> <sY8yS-4e0-47@gated-at.bofh.it> <sY9EC-4Q2-1@gated-at.bofh.it> <sYaKl-5sT-1@gated-at.bofh.it> |
| Organization | linux.* mail to news gateway |
Hello Rob,
On 01/10/2017 04:55 PM, Javier Martinez Canillas wrote:
> Hello Krzysztof,
>
> On 01/10/2017 03:47 PM, Krzysztof Kozlowski wrote:
>> On Tue, Jan 10, 2017 at 02:38:30PM -0300, Javier Martinez Canillas wrote:
>>> This patch fixes the following DTC warning about a mismatch
>>> between a device node reg property and its unit name:
>>>
>>> Node /soc has a reg or ranges property, but no unit name
>>>
>>> Signed-off-by: Javier Martinez Canillas <javier@osg.samsung.com>
>>> ---
>>>
>>> arch/arm64/boot/dts/exynos/exynos7.dtsi | 2 +-
>>> 1 file changed, 1 insertion(+), 1 deletion(-)
>>>
>>> diff --git a/arch/arm64/boot/dts/exynos/exynos7.dtsi b/arch/arm64/boot/dts/exynos/exynos7.dtsi
>>> index 80aa60e38237..0d2fedc6ac2f 100644
>>> --- a/arch/arm64/boot/dts/exynos/exynos7.dtsi
>>> +++ b/arch/arm64/boot/dts/exynos/exynos7.dtsi
>>> @@ -69,7 +69,7 @@
>>> method = "smc";
>>> };
>>>
>>> - soc: soc {
>>> + soc: soc@0 {
>>
>> This looks unnatural, like a fix just to silence the DTC. Mostly de do
>> not enumerate soc node, although there are few exceptions.
>>
>
> Yes, but OTOH arm32 Exynos SoCs just have an empty "ranges" property in their
> soc device node (parent and child address space is the same, no translation)
> so DTC doesn't complain about the unit address in those.
>
> But others SoCs DTSI with a non-empty ranges property have an unit name in
> their soc nodes, i.e for arm64 and arm32:
>
> arch/arm64/boot/dts/marvell/berlin4ct.dtsi
>
> arch/arm/boot/dts/da850.dtsi
>
>> I would prefer ignore the warning... however I am happy to hear other opinions.
>>
>
> If is wrong/unnatural to have addresses for soc nodes then I think DTC should
> be patched to ignore these (like it will be the case for the OPP nodes AFAIU).
>
Any comments about this?
>> Best regards,
>> Krzysztof
>>
>
> Best regards,
>
Best regards,
--
Javier Martinez Canillas
Open Source Group
Samsung Research America
Back to linux.kernel | Previous | Next | Find similar | Unroll thread
Re: [PATCH v2 1/3] arm64: dts: exynos: Add missing unit name to Exynos7 SoC node Javier Martinez Canillas <javier@osg.samsung.com> - 2017-02-20 15:10 +0100
csiph-web