Hi Krzysztof,



On 12 February 2017 at 01:44, Krzysztof Kozlowski <krzk@kernel.org> wrote:
> In Odroid XU3 Lite board, the temperature levels reported for thermal
> zone 0 were weird. In warm room:
>         /sys/class/thermal/thermal_zone0/temp:32000
>         /sys/class/thermal/thermal_zone1/temp:51000
>         /sys/class/thermal/thermal_zone2/temp:55000
>         /sys/class/thermal/thermal_zone3/temp:54000
>         /sys/class/thermal/thermal_zone4/temp:51000
>
> Sometimes after booting the value was even equal to ambient temperature
> which is highly unlikely to be a real temperature of sensor in SoC.
>
> The thermal sensor's calibration (trimming) is based on fused values.
> In case of the board above, the fused values are: 35, 52, 43, 58 and 43
> (corresponding to each TMU device).  However driver defined a minimum value
> for fused data as 40 and for smaller values it was using a hard-coded 55
> instead.  This lead to mapping data from sensor to wrong temperatures
> for thermal zone 0.
>
> Various vendor 3.10 trees (Hardkernel's based on Samsung LSI, Artik 10)
> do not impose any limits on fused values.  Since we do not have any
> knowledge about these limits, use 0 as a minimum accepted fused value.
> This should essentially allow accepting any reasonable fused value thus
> behaving like vendor driver.
>

On HK following values are define in drivers/thermal/exynos_thermal.c

#define EFUSE_MIN_VALUE                         40
#define EFUSE_MAX_VALUE                         100

> The exynos5420-tmu-sensor-conf.dtsi is copied directly from existing
> exynso4412 with one change - the samsung,tmu_min_efuse_value.
>
> Signed-off-by: Krzysztof Kozlowski <krzk@kernel.org>
>
> ---

Best Regards
-Anand

Back to linux.kernel | Previous | NextPrevious in thread | Next in thread | Find similar | Unroll thread


Thread

[PATCH] ARM: dts: exynos: Use thermal fuse value for thermal zone 0 on Exynos5420 Krzysztof Kozlowski <krzk@kernel.org> - 2017-02-11 21:20 +0100
  Re: [PATCH] ARM: dts: exynos: Use thermal fuse value for thermal zone  0 on Exynos5420 Anand Moon <linux.amoon@gmail.com> - 2017-02-13 12:40 +0100
    Re: [PATCH] ARM: dts: exynos: Use thermal fuse value for thermal zone  0 on Exynos5420 Krzysztof Kozlowski <krzk@kernel.org> - 2017-02-13 13:00 +0100
      Re: [PATCH] ARM: dts: exynos: Use thermal fuse value for thermal zone  0 on Exynos5420 Anand Moon <linux.amoon@gmail.com> - 2017-02-13 13:30 +0100
  Re: [PATCH] ARM: dts: exynos: Use thermal fuse value for thermal zone  0 on Exynos5420 Bartlomiej Zolnierkiewicz <b.zolnierkie@samsung.com> - 2017-02-13 17:30 +0100
  Re: [PATCH] ARM: dts: exynos: Use thermal fuse value for thermal  zone 0 on Exynos5420 Eduardo Valentin <edubezval@gmail.com> - 2017-02-19 01:40 +0100

csiph-web