| From | Pavel Machek <pavel@ucw.cz> |
|---|---|
| Newsgroups | linux.kernel |
| Subject | Re: [RFC] shutdown machine when li-ion battery goes below 3V |
| Date | 2016-10-24 23:50 +0200 |
| Message-ID | <svVi1-4Oo-13@gated-at.bofh.it> (permalink) |
| References | <svUYF-4HF-3@gated-at.bofh.it> <svUYF-4HF-1@gated-at.bofh.it> |
| Organization | linux.* mail to news gateway |
[Multipart message — attachments visible in raw view] - view raw
On Mon 2016-10-24 14:29:33, Tony Lindgren wrote: > * Pavel Machek <pavel@ucw.cz> [161024 14:24]: > > Hi! > > > > What about something like this? N900 will drain the battery down to > > system crash, which is quite uncool. > > Can't we make that generic and configurable for the voltage somehow? I was afraid someone would ask :-). Yes, we probably need to create battery object in the device tree, then add properties there. > Also, the shutdown voltage can depend on external devices connected. > It could be for example 3.3V depending on eMMC on some devices while > devices with no eMMC could have it at 3.0V. Actually, I'd like to shutdown at 3.3V or more (like 3.5V), because going below that is pretty mean to the battery. But if I set threshold too high, GSM activity will push it below that for a very short while, and I'll shutdown too soon. Ideas welcome... Pavel -- (english) http://www.livejournal.com/~pavelmachek (cesky, pictures) http://atrey.karlin.mff.cuni.cz/~pavel/picture/horses/blog.html
Back to linux.kernel | Previous | Next — Previous in thread | Next in thread | Find similar | Unroll thread
[RFC] shutdown machine when li-ion battery goes below 3V Pavel Machek <pavel@ucw.cz> - 2016-10-24 23:30 +0200
Re: [RFC] shutdown machine when li-ion battery goes below 3V Tony Lindgren <tony@atomide.com> - 2016-10-24 23:30 +0200
Re: [RFC] shutdown machine when li-ion battery goes below 3V Pavel Machek <pavel@ucw.cz> - 2016-10-24 23:50 +0200
Re: [RFC] shutdown machine when li-ion battery goes below 3V Pali Rohár <pali.rohar@gmail.com> - 2016-10-24 23:50 +0200
Re: [RFC] shutdown machine when li-ion battery goes below 3V Pavel Machek <pavel@ucw.cz> - 2016-10-25 12:30 +0200
Re: [RFC] shutdown machine when li-ion battery goes below 3V Pali Rohár <pali.rohar@gmail.com> - 2016-10-25 13:00 +0200
Re: [RFC] shutdown machine when li-ion battery goes below 3V Pavel Machek <pavel@ucw.cz> - 2016-10-25 13:00 +0200
Re: [RFC] shutdown machine when li-ion battery goes below 3V Pali Rohár <pali.rohar@gmail.com> - 2016-10-25 13:00 +0200