Heck, why did the server freeze? Alessandro Vesely <vesely@tana.it> - 2018-10-25 20:00 +0200
Re: Heck, why did the server freeze? Brian <ad44@cityscape.co.uk> - 2018-10-25 20:40 +0200
Re: Heck, why did the server freeze? Alessandro Vesely <vesely@tana.it> - 2018-10-26 11:30 +0200
Re: Heck, why did the server freeze? Reco <recoverym4n@enotuniq.net> - 2018-10-26 11:30 +0200
Re: Heck, why did the server freeze? Joe <joe@jretrading.com> - 2018-10-26 18:10 +0200
Re: Heck, why did the server freeze? Alessandro Vesely <vesely@tana.it> - 2018-10-26 19:40 +0200
Re: Heck, why did the server freeze? Reco <recoverym4n@enotuniq.net> - 2018-10-26 20:20 +0200
| From | Alessandro Vesely <vesely@tana.it> |
|---|---|
| Date | 2018-10-25 20:00 +0200 |
| Subject | Heck, why did the server freeze? |
| Message-ID | <wMS5k-1PA-15@gated-at.bofh.it> |
Hi all, early this morning a network card burned out. A few hours later, the server was not responding on any network address, nor on the system console. I had to power it down. Upon rebooting, network errors were detected an I arranged the server to work with the available hardware. The last line logged was an incoming email from a spammer in Brazil. It shouldn't have triggered any severe damage. I found no breakdown hint in the logs. My theory is that the system didn't realize that the card was broken, didn't turn the interface down, and kept storing outgoing stuff until it blew off. Is that reasonable or should I be more paranoid? TIA for any answer Best Ale
[toc] | [next] | [standalone]
| From | Brian <ad44@cityscape.co.uk> |
|---|---|
| Date | 2018-10-25 20:40 +0200 |
| Message-ID | <wMSI1-2hB-1@gated-at.bofh.it> |
| In reply to | #201627 |
On Thu 25 Oct 2018 at 19:53:26 +0200, Alessandro Vesely wrote: > Hi all, > early this morning a network card burned out. A few hours later, the server > was not responding on any network address, nor on the system console. I had to > power it down. > > Upon rebooting, network errors were detected an I arranged the server to work > with the available hardware. The last line logged was an incoming email from a > spammer in Brazil. It shouldn't have triggered any severe damage. I found no > breakdown hint in the logs. > > My theory is that the system didn't realize that the card was broken, didn't > turn the interface down, and kept storing outgoing stuff until it blew off. Is > that reasonable or should I be more paranoid? You have given an exact diagnosis of your problem - the network card failed. What's your problem? Replace it instead of agonising and theorising. -- Brian.
[toc] | [prev] | [next] | [standalone]
| From | Alessandro Vesely <vesely@tana.it> |
|---|---|
| Date | 2018-10-26 11:30 +0200 |
| Message-ID | <wN6Bj-2fr-1@gated-at.bofh.it> |
| In reply to | #201630 |
On Thu 25/Oct/2018 20:30:27 +0200 Brian wrote: > On Thu 25 Oct 2018 at 19:53:26 +0200, Alessandro Vesely wrote: > >> Hi all, >> early this morning a network card burned out. A few hours later, the server >> was not responding on any network address, nor on the system console. I had to >> power it down. >> >> Upon rebooting, network errors were detected an I arranged the server to work >> with the available hardware. The last line logged was an incoming email from a >> spammer in Brazil. It shouldn't have triggered any severe damage. I found no >> breakdown hint in the logs. >> >> My theory is that the system didn't realize that the card was broken, didn't >> turn the interface down, and kept storing outgoing stuff until it blew off. Is >> that reasonable or should I be more paranoid? > > You have given an exact diagnosis of your problem - the network > card failed. What's your problem? Replace it instead of agonising > and theorising. The problem is that the server froze. I don't think that's what it is supposed to do when a card fails. During the reboot, I had a plethora of RTNETLINK answers: Network is down / Network is unreachable / File exists. It took me several RJ45 swaps to know which network and which side of the link were the culprit. Contrast that with log lines about anything else, from non-redundant power supplies to failed GPG signatures. In part, the missing precise diagnosis must be a shortcoming on part of the card vendor. However, how come the kernel didn't realize that the link had to go down, log something, and just fail any subsequent call on that interface, instead of freezing? Or did it freeze for an unrelated reason? Best Ale -- P.S. New card expected on Monday.
[toc] | [prev] | [next] | [standalone]
| From | Reco <recoverym4n@enotuniq.net> |
|---|---|
| Date | 2018-10-26 11:30 +0200 |
| Message-ID | <wN6Bk-2fr-7@gated-at.bofh.it> |
| In reply to | #201669 |
Hi. On Fri, Oct 26, 2018 at 11:23:39AM +0200, Alessandro Vesely wrote: > On Thu 25/Oct/2018 20:30:27 +0200 Brian wrote: > > On Thu 25 Oct 2018 at 19:53:26 +0200, Alessandro Vesely wrote: > > > >> Hi all, > >> early this morning a network card burned out. A few hours later, the server > >> was not responding on any network address, nor on the system console. I had to > >> power it down. > >> > >> Upon rebooting, network errors were detected an I arranged the server to work > >> with the available hardware. The last line logged was an incoming email from a > >> spammer in Brazil. It shouldn't have triggered any severe damage. I found no > >> breakdown hint in the logs. > >> > >> My theory is that the system didn't realize that the card was broken, didn't > >> turn the interface down, and kept storing outgoing stuff until it blew off. Is > >> that reasonable or should I be more paranoid? > > > > You have given an exact diagnosis of your problem - the network > > card failed. What's your problem? Replace it instead of agonising > > and theorising. > > The problem is that the server froze. I don't think that's what it is supposed > to do when a card fails. It's my impression too. > Contrast that with log lines about anything else, from non-redundant power > supplies to failed GPG signatures. In part, the missing precise diagnosis must > be a shortcoming on part of the card vendor. However, how come the kernel > didn't realize that the link had to go down, log something, and just fail any > subsequent call on that interface, instead of freezing? Or did it freeze for > an unrelated reason? I believe that it's impossible to answer this question. It's highly likely that it was kernel panic. Whenever it was related to failed NIC, or no - it's impossible to tell since there's no kernel backtrace. I'd install, say, kdump-tools for the future incidents like this. Reco
[toc] | [prev] | [next] | [standalone]
| From | Joe <joe@jretrading.com> |
|---|---|
| Date | 2018-10-26 18:10 +0200 |
| Message-ID | <wNcQp-61w-1@gated-at.bofh.it> |
| In reply to | #201670 |
On Fri, 26 Oct 2018 12:27:36 +0300 Reco <recoverym4n@enotuniq.net> wrote: > Hi. > > > > > The problem is that the server froze. I don't think that's what it > > is supposed to do when a card fails. > > It's my impression too. > A bad peripheral can cause almost any problem. If the bit of the card connecting with the outside world fails, it probably won't affect the rest of the computer. If a bit involving e.g. the PCI bus fails, it may well stop other stuff from working, maybe the CPU itself. To be fair, it's usually the outside bit that dies, often because of the fact that it's connected to other equipment. I had a dead PC a week ago. No PSU fan, even. Reseating the PATA cable leading to the optical drives fixed it... and I've seen, at least twice, a bad optical drive preventing start-up. -- Joe
[toc] | [prev] | [next] | [standalone]
| From | Alessandro Vesely <vesely@tana.it> |
|---|---|
| Date | 2018-10-26 19:40 +0200 |
| Message-ID | <wNefw-6Js-3@gated-at.bofh.it> |
| In reply to | #201670 |
On Fri 26/Oct/2018 11:27:36 +0200 Reco wrote: > On Fri, Oct 26, 2018 at 11:23:39AM +0200, Alessandro Vesely wrote: >> The problem is that the server froze. I don't think that's what it is supposed >> to do when a card fails. > > It's my impression too. In general, it is too difficult to know if a link is good, at least on the local side. I found nothing better than running pings by cron. >> Contrast that with log lines about anything else, from non-redundant power >> supplies to failed GPG signatures. In part, the missing precise diagnosis must >> be a shortcoming on part of the card vendor. However, how come the kernel >> didn't realize that the link had to go down, log something, and just fail any >> subsequent call on that interface, instead of freezing? Or did it freeze for >> an unrelated reason? > > I believe that it's impossible to answer this question. It's highly > likely that it was kernel panic. Whenever it was related to failed NIC, > or no - it's impossible to tell since there's no kernel backtrace. Right. I should have tried Ctrl-Alt-F1 or some of the SysRq hacks[*], but I was too upset by services not responding... [*] https://www.kernel.org/doc/html/latest/admin-guide/sysrq.html > I'd install, say, kdump-tools for the future incidents like this. Just installed, thank you! (I'll reboot when the new card arrives). Best Ale --
[toc] | [prev] | [next] | [standalone]
| From | Reco <recoverym4n@enotuniq.net> |
|---|---|
| Date | 2018-10-26 20:20 +0200 |
| Message-ID | <wNeSe-7bh-11@gated-at.bofh.it> |
| In reply to | #201697 |
On Fri, Oct 26, 2018 at 07:38:56PM +0200, Alessandro Vesely wrote: > On Fri 26/Oct/2018 11:27:36 +0200 Reco wrote: > > On Fri, Oct 26, 2018 at 11:23:39AM +0200, Alessandro Vesely wrote: > >> The problem is that the server froze. I don't think that's what it is supposed > >> to do when a card fails. > > > > It's my impression too. > > In general, it is too difficult to know if a link is good, at least on the > local side. I found nothing better than running pings by cron. lldpd, there's no substitutes for that in a single L2 segment. Taking WAN into account, pings seem the most reasonable way. Reco
[toc] | [prev] | [standalone]