Groups | Search | Server Info | Keyboard shortcuts | Login | Register [http] [https] [nntp] [nntps]


Groups > linux.debian.user > #174015 > unrolled thread

Power Cut

Started byHadi Motamedi <motamedi24@gmail.com>
First post2016-10-30 07:40 +0100
Last post2016-10-31 08:50 +0100
Articles 8 — 5 participants

Back to article view | Back to linux.debian.user


Contents

  Power Cut Hadi Motamedi <motamedi24@gmail.com> - 2016-10-30 07:40 +0100
    Re: Power Cut Gene Heskett <gheskett@shentel.net> - 2016-10-30 08:40 +0100
      Re: Power Cut Hadi Motamedi <motamedi24@gmail.com> - 2016-10-30 08:50 +0100
      Re: Power Cut Lisi Reisz <lisi.reisz@gmail.com> - 2016-10-30 13:10 +0100
        Re: Power Cut Gene Heskett <gheskett@shentel.net> - 2016-10-30 14:30 +0100
    Re: Power Cut Andre Majorel <aym-naibed@teaser.fr> - 2016-10-30 10:10 +0100
      Re: Power Cut Reco <recoverym4n@gmail.com> - 2016-10-30 10:30 +0100
        Re: Power Cut Andre Majorel <aym-naibed@teaser.fr> - 2016-10-31 08:50 +0100

#174015 — Power Cut

FromHadi Motamedi <motamedi24@gmail.com>
Date2016-10-30 07:40 +0100
SubjectPower Cut
Message-ID<sxRWF-173-5@gated-at.bofh.it>

[Multipart message — attachments visible in raw view] — view raw

Dear All
I am using a debian server for cdr billing and mediation device on a remote
network. I am experiencing problem that I am suspicious it comes from main
supply power cut at the remote site. The power supply to the remote site
comes from battery charger that will be automatically switched in circuit
under main supply power cut but cannot provide adequate power for more than
2 hours . I am suspicious that the remote system is suffering from many
frequent main supply power cut . Can you please do me favor and let me know
if there is any log on my debian server that I can check to see if there
would be many frequent power cut there ?
Thank you for your time

[toc] | [next] | [standalone]


#174016

FromGene Heskett <gheskett@shentel.net>
Date2016-10-30 08:40 +0100
Message-ID<sxSSJ-1Fu-1@gated-at.bofh.it>
In reply to#174015
On Sunday 30 October 2016 02:37:28 Hadi Motamedi wrote:

> Dear All
> I am using a debian server for cdr billing and mediation device on a
> remote network. I am experiencing problem that I am suspicious it
> comes from main supply power cut at the remote site. The power supply
> to the remote site comes from battery charger that will be
> automatically switched in circuit under main supply power cut but
> cannot provide adequate power for more than 2 hours . I am suspicious
> that the remote system is suffering from many frequent main supply
> power cut . Can you please do me favor and let me know if there is any
> log on my debian server that I can check to see if there would be many
> frequent power cut there ?
> Thank you for your time

Likely the only log will be /var/log/messages, which will show the reboot 
time when power has been restored, IF the server is set to auto-boot 
when power is restored. That should show when it restarted but may not 
log the power failure because it doesn't have time to write the log.
So you can get your restart times, but not the fail time.

Is that "battery charger" smart enough to be interfaced with nut?

Thats short for Network UPS Tools, which can monitor and log such 
activities, and even issue a clean shutdown to the whole system running 
on this emergency power when the battery is nearly depleted. I'd also 
see if natural gas is available at the site, so that a generator can be 
started when the main power fails.

Going whole house and all my toys I have a 20 Kwh Generac here that 
starts automatically, so I have power back up in about 5 seconds, but 
that was in the $7000 range installed.  The wife has copd, and long 
periods w/o the AC are very hard on her, so I did what I had to do.
This machine has a UPS, but most of the others here are set to 
auto-reboot when power is restored.

Enterprising individuals can likely setup much smaller emergency/standby 
power since all it would take in a pi or arduino and some programming to 
send the start and stop commands if it had an electric starter and  
kill.  You will need a "transfer" switch which must absolutely prevent 
any locally generated power from feeding out into a failed power line as 
that might kill someone trying to restore the power some distance away 
from your site.

Here in the states, kohler, generac, & a dozen house brands peddle 
smaller such generators, but are not always proportionately priced. Most 
of the teeny ones are 2 strokers, needing mixed fuel, don't have 
electric starters and in my experience are run 3 or 4 times junk so you 
wasted that $300. I suspect you are not in the "states" so I don't have 
a good idea what may be locally available for you.

Just throwing out ideas to see if anything "sticks to the wall" :)

Cheers, Gene Heskett
-- 
"There are four boxes to be used in defense of liberty:
 soap, ballot, jury, and ammo. Please use in that order."
-Ed Howdershelt (Author)
Genes Web page <http://geneslinuxbox.net:6309/gene>

[toc] | [prev] | [next] | [standalone]


#174017

FromHadi Motamedi <motamedi24@gmail.com>
Date2016-10-30 08:50 +0100
Message-ID<sxT2p-1IM-3@gated-at.bofh.it>
In reply to#174016

[Multipart message — attachments visible in raw view] — view raw

Thank you very much for your reply . I got the point and it seems that the
/var/log/messages are more handy .
Thank you again for your time


On Sun, Oct 30, 2016 at 12:36 AM, Gene Heskett <gheskett@shentel.net> wrote:

> On Sunday 30 October 2016 02:37:28 Hadi Motamedi wrote:
>
> > Dear All
> > I am using a debian server for cdr billing and mediation device on a
> > remote network. I am experiencing problem that I am suspicious it
> > comes from main supply power cut at the remote site. The power supply
> > to the remote site comes from battery charger that will be
> > automatically switched in circuit under main supply power cut but
> > cannot provide adequate power for more than 2 hours . I am suspicious
> > that the remote system is suffering from many frequent main supply
> > power cut . Can you please do me favor and let me know if there is any
> > log on my debian server that I can check to see if there would be many
> > frequent power cut there ?
> > Thank you for your time
>
> Likely the only log will be /var/log/messages, which will show the reboot
> time when power has been restored, IF the server is set to auto-boot
> when power is restored. That should show when it restarted but may not
> log the power failure because it doesn't have time to write the log.
> So you can get your restart times, but not the fail time.
>
> Is that "battery charger" smart enough to be interfaced with nut?
>
> Thats short for Network UPS Tools, which can monitor and log such
> activities, and even issue a clean shutdown to the whole system running
> on this emergency power when the battery is nearly depleted. I'd also
> see if natural gas is available at the site, so that a generator can be
> started when the main power fails.
>
> Going whole house and all my toys I have a 20 Kwh Generac here that
> starts automatically, so I have power back up in about 5 seconds, but
> that was in the $7000 range installed.  The wife has copd, and long
> periods w/o the AC are very hard on her, so I did what I had to do.
> This machine has a UPS, but most of the others here are set to
> auto-reboot when power is restored.
>
> Enterprising individuals can likely setup much smaller emergency/standby
> power since all it would take in a pi or arduino and some programming to
> send the start and stop commands if it had an electric starter and
> kill.  You will need a "transfer" switch which must absolutely prevent
> any locally generated power from feeding out into a failed power line as
> that might kill someone trying to restore the power some distance away
> from your site.
>
> Here in the states, kohler, generac, & a dozen house brands peddle
> smaller such generators, but are not always proportionately priced. Most
> of the teeny ones are 2 strokers, needing mixed fuel, don't have
> electric starters and in my experience are run 3 or 4 times junk so you
> wasted that $300. I suspect you are not in the "states" so I don't have
> a good idea what may be locally available for you.
>
> Just throwing out ideas to see if anything "sticks to the wall" :)
>
> Cheers, Gene Heskett
> --
> "There are four boxes to be used in defense of liberty:
>  soap, ballot, jury, and ammo. Please use in that order."
> -Ed Howdershelt (Author)
> Genes Web page <http://geneslinuxbox.net:6309/gene>
>
>

[toc] | [prev] | [next] | [standalone]


#174024

FromLisi Reisz <lisi.reisz@gmail.com>
Date2016-10-30 13:10 +0100
Message-ID<sxX61-4sU-5@gated-at.bofh.it>
In reply to#174016
On Sunday 30 October 2016 07:36:23 Gene Heskett wrote:
> I'd also
> see if natural gas is available at the site, so that a generator can be
> started when the main power fails.

Gene -  Why only natural gas?  Is this a linguistic matter or technical? Why 
would this not work with say, coal gas, Calor gas (which can be at any site) 
etc..  Why only *natural* gas?  Or is "natural gas" US-speak for "gaseous 
gas" as opposed to liquid gas, which you call gas and we call petrol?

Lisi

[toc] | [prev] | [next] | [standalone]


#174030

FromGene Heskett <gheskett@shentel.net>
Date2016-10-30 14:30 +0100
Message-ID<sxYlr-5b8-25@gated-at.bofh.it>
In reply to#174024
On Sunday 30 October 2016 08:03:57 Lisi Reisz wrote:

> On Sunday 30 October 2016 07:36:23 Gene Heskett wrote:
> > I'd also
> > see if natural gas is available at the site, so that a generator can
> > be started when the main power fails.
>
> Gene -  Why only natural gas?  Is this a linguistic matter or
> technical? Why would this not work with say, coal gas, Calor gas
> (which can be at any site) etc..  Why only *natural* gas?  Or is
> "natural gas" US-speak for "gaseous gas" as opposed to liquid gas,
> which you call gas and we call petrol?
>
> Lisi

Thats the common terminology on this side of the pond, to distinguish it 
from propane, which can also be used, but propane is normally stored in 
high pressure tankage of from 100 lbs to 5000 gallons.  Natural comes 
from the well with a bit of debris filtering and would not be used up 
until that well network was out of gas, possibly another 100 years.  The 
propane tanks contents OTOH, will eventually be used up and will require 
refilling.  So we tend to equate "natural" as a continuously available 
supply.

So yes, language differences. As has been said many times, Great Britain, 
and the USA, two great  countries separated by a common language. :)

Somehow, I get the impression that the OP may be in the back country of 
India, but he has not confirmed it.

Cheers, Gene Heskett
-- 
"There are four boxes to be used in defense of liberty:
 soap, ballot, jury, and ammo. Please use in that order."
-Ed Howdershelt (Author)
Genes Web page <http://geneslinuxbox.net:6309/gene>

[toc] | [prev] | [next] | [standalone]


#174019

FromAndre Majorel <aym-naibed@teaser.fr>
Date2016-10-30 10:10 +0100
Message-ID<sxUhP-2EK-1@gated-at.bofh.it>
In reply to#174015
On 2016-10-29 23:37 -0700, Hadi Motamedi wrote:

> I am using a debian server for cdr billing and mediation
> device on a remote network. I am experiencing problem that I
> am suspicious it comes from main supply power cut at the
> remote site. The power supply to the remote site comes from
> battery charger that will be automatically switched in circuit
> under main supply power cut but cannot provide adequate power
> for more than 2 hours . I am suspicious that the remote system
> is suffering from many frequent main supply power cut.
>
> Can you please do me favor and let me know if there is any log
> on my debian server that I can check to see if there would be
> many frequent power cut there ?

If you mean reboots, you could try something like

  zgrep ' Command line: BOOT_IMAGE=' /var/log/syslog*

Alternatively, look into commands such as last(1), uptime(1),
utmpdump(1) or who(1).

If you mean power outages short enough to not cause the computer
to shut down or reboot, I suspect you'd need special hardware to
monitor the mains voltage and report variations to the computer.
I don't think your ordinary ATX power supply does that but lots
of UPS do.

-- 
André Majorel <http://www.teaser.fr/~amajorel/>
bugs.debian.org, your one-stop shop for email addresses.

[toc] | [prev] | [next] | [standalone]


#174021

FromReco <recoverym4n@gmail.com>
Date2016-10-30 10:30 +0100
Message-ID<sxUBb-2Lv-7@gated-at.bofh.it>
In reply to#174019
	Hi.

On Sun, 30 Oct 2016 10:06:30 +0100
Andre Majorel <aym-naibed@teaser.fr> wrote:

> On 2016-10-29 23:37 -0700, Hadi Motamedi wrote:
> 
> > I am using a debian server for cdr billing and mediation
> > device on a remote network. I am experiencing problem that I
> > am suspicious it comes from main supply power cut at the
> > remote site. The power supply to the remote site comes from
> > battery charger that will be automatically switched in circuit
> > under main supply power cut but cannot provide adequate power
> > for more than 2 hours . I am suspicious that the remote system
> > is suffering from many frequent main supply power cut.
> >
> > Can you please do me favor and let me know if there is any log
> > on my debian server that I can check to see if there would be
> > many frequent power cut there ?
> 
> If you mean reboots, you could try something like
> 
>   zgrep ' Command line: BOOT_IMAGE=' /var/log/syslog*
> 
> Alternatively, look into commands such as last(1), uptime(1),
> utmpdump(1) or who(1).

Won't a simple "last | grep boot" suffice?

Reco

[toc] | [prev] | [next] | [standalone]


#174067

FromAndre Majorel <aym-naibed@teaser.fr>
Date2016-10-31 08:50 +0100
Message-ID<syfvX-7MY-9@gated-at.bofh.it>
In reply to#174021
On 2016-10-30 12:25 +0300, Reco wrote:
> On Sun, 30 Oct 2016 10:06:30 +0100
> Andre Majorel <aym-naibed@teaser.fr> wrote:
> > On 2016-10-29 23:37 -0700, Hadi Motamedi wrote:
> > >
> > > Can you please do me favor and let me know if there is any log
> > > on my debian server that I can check to see if there would be
> > > many frequent power cut there ?
> > 
> > If you mean reboots, you could try something like
> > 
> >   zgrep ' Command line: BOOT_IMAGE=' /var/log/syslog*
> > 
> > Alternatively, look into commands such as last(1), uptime(1),
> > utmpdump(1) or who(1).
> 
> Won't a simple "last | grep boot" suffice?

If the man page is not lying, "last reboot" will. But none of
the machines I have access to reboot often enough for me to make
sure.

-- 
André Majorel <http://www.teaser.fr/~amajorel/>
Plusieurs grandes marques de spambots recommandent lists.debian.org.

[toc] | [prev] | [standalone]


Back to top | Article view | linux.debian.user


csiph-web