Groups | Search | Server Info | Keyboard shortcuts | Login | Register [http] [https] [nntp] [nntps]


Groups > comp.soft-sys.math.mathematica > #14830

Re: System Modeler and Mathematica 9

From Johan Rhodin <johanr@wolfram.com>
Newsgroups comp.soft-sys.math.mathematica
Subject Re: System Modeler and Mathematica 9
Date 2013-06-13 06:31 +0000
Message-ID <kpbp0r$95h$1@smc.vnet.net> (permalink)
Organization Time-Warner Telecom

Show all headers | View raw


Hi Paul,

SystemModeler 3.0.2 works fine with Mathematica 9.
Your demo license is restricted to one SystemModeler kernel, so maybe you already have one tied up to Mathematica 8. This could be why your WSMLink doesn't load in Mathematica 9. Make sure to quit Mathemaitca 8 before trying to run Needs["WSMLink`"] in Mathematica 9. 

/Johan

----- Original Message -----
From: "Paul McHale" <Paul.McHale@excelitas.com>
Sent: Tuesday, June 11, 2013 1:34:12 AM
Subject:  System Modeler and Mathematica 9

I have a problem with Mathematica 9.0 (Win) reading the models.  The following code starts with a blue box showing it is initiating the link.  In 9.0, the box will sometimes never disappear.  In 8.0, this is never a problem. Should I just stay with 8.0 for now?  Are there known problems with 9.0?  I am using a demo of SystemModeler.

Needs["WSMLink`"]
m=WSMSimulate["ResistorDividerTripLevel",{0,1}]
m["ParameterValues"] // TableForm

WSMSimulationData[{0.,1.},<<42>>]

resistor1.useHeatPort->0.
resistor1.T->300.15
resistor1.R->11000.
resistor1.T_ref->300.15



Thanks,

Paul McHale  |  Electrical Engineer, Energetic Systems   |  Excelitas Technologies Corp.

Office: +1 937.865.3004   |  Fax: +1 937.865.5170
1100 Vanguard Boulevard, Miamisburg, OH  45342-0312
Paul.McHale@Excelitas.com
www.excelitas.com


Back to comp.soft-sys.math.mathematica | Previous | Next | Find similar | Unroll thread


Thread

Re:  System Modeler and Mathematica 9 Johan Rhodin <johanr@wolfram.com> - 2013-06-13 06:31 +0000

csiph-web