Paul Rubin <no.email@nospam.invalid> writes:
>anton@mips.complang.tuwien.ac.at (Anton Ertl) writes:
>> Do such small systems support FP at all? AmForth does not, judging by
>> its reference card.
>
>I thought the whole motivation for recognizers was that AmForth had
>optional floating point and Matthias wanted a way to cleanly make
>parsing of FP numbers optional too.
That may be the case, but MSP430 and AVR8 (the two targets of AmForth)
seem to have no FP hardware, so no change in alignment requirements.
- anton
--
M. Anton Ertl http://www.complang.tuwien.ac.at/anton/home.html
comp.lang.forth FAQs: http://www.complang.tuwien.ac.at/forth/faq/toc.html
New standard: http://www.forth200x.org/forth200x.html
EuroForth 2016: http://www.euroforth.org/ef16/
Back to comp.lang.forth | Previous | Next — Previous in thread | Find similar | Unroll thread
Rosetta Code: Accumulator factory "Robert L." <No_spamming@noWhere_7073.org> - 2017-01-17 09:00 +0000
Re: Rosetta Code: Accumulator factory Paul Rubin <no.email@nospam.invalid> - 2017-01-17 01:38 -0800
Re: Rosetta Code: Accumulator factory anton@mips.complang.tuwien.ac.at (Anton Ertl) - 2017-01-17 13:54 +0000
Re: Rosetta Code: Accumulator factory Paul Rubin <no.email@nospam.invalid> - 2017-01-17 13:10 -0800
Re: Rosetta Code: Accumulator factory Andrew Haley <andrew29@littlepinkcloud.invalid> - 2017-01-18 03:15 -0600
Re: Rosetta Code: Accumulator factory anton@mips.complang.tuwien.ac.at (Anton Ertl) - 2017-01-18 13:43 +0000
Re: Rosetta Code: Accumulator factory Paul Rubin <no.email@nospam.invalid> - 2017-01-18 13:20 -0800
Re: Rosetta Code: Accumulator factory albert@cherry.spenarnc.xs4all.nl (Albert van der Horst) - 2017-01-19 02:40 +0100
Re: Rosetta Code: Accumulator factory anton@mips.complang.tuwien.ac.at (Anton Ertl) - 2017-01-19 16:27 +0000
csiph-web