Magellan 8100 Scale/Scanner "Craig Dawson" <craig_dawson@hotmail.com> - 2013-12-19 16:07 +1100
Re: Magellan 8100 Scale/Scanner Jesus Zertuche <jzertucherodriguez@gmail.com> - 2013-12-19 12:49 -0800
Re: Magellan 8100 Scale/Scanner "Craig Dawson" <craig_dawson@hotmail.com> - 2013-12-20 12:50 +1100
Re: Magellan 8100 Scale/Scanner "Gerhard Bunzel" <g.bunzel@domonet.de> - 2013-12-20 00:07 +0100
Re: Magellan 8100 Scale/Scanner "Craig Dawson" <craig_dawson@hotmail.com> - 2013-12-20 12:47 +1100
Re: Magellan 8100 Scale/Scanner "Gerhard Bunzel" <g.bunzel@domonet.de> - 2013-12-20 11:02 +0100
| From | "Craig Dawson" <craig_dawson@hotmail.com> |
|---|---|
| Date | 2013-12-19 16:07 +1100 |
| Subject | Magellan 8100 Scale/Scanner |
| Message-ID | <l8tuuh$hjv$1@dont-email.me> |
Hi all. I've been trying to communicate with a PSC Magellan 8100 Omega POS Scale/Barcode Scanner using Ginny's serial class but am having little success. Does anyone have any sample code that might help me out? Regards, Craig.
[toc] | [next] | [standalone]
| From | Jesus Zertuche <jzertucherodriguez@gmail.com> |
|---|---|
| Date | 2013-12-19 12:49 -0800 |
| Message-ID | <7d0c7212-b328-438c-a377-10539a205877@googlegroups.com> |
| In reply to | #6428 |
El miércoles, 18 de diciembre de 2013 23:07:27 UTC-6, Craig Dawson escribió: > Hi all. I've been trying to communicate with a PSC Magellan 8100 Omega POS > > Scale/Barcode Scanner using Ginny's serial class but am having little > > success. > > Does anyone have any sample code that might help me out? > > Regards, Craig. Hi Craig: I used the free OPOS library to do that. http://monroecs.com/oposccos_current.htm Maybe you serve... Regards, Jesus.
[toc] | [prev] | [next] | [standalone]
| From | "Craig Dawson" <craig_dawson@hotmail.com> |
|---|---|
| Date | 2013-12-20 12:50 +1100 |
| Message-ID | <l907oh$bgp$1@dont-email.me> |
| In reply to | #6433 |
Thanks Jesus but what I am looking for is a solution from within VO itself. Hopefully someone here has had a similar experience and knows the answer. Kind Regards, Craig. "Jesus Zertuche" <jzertucherodriguez@gmail.com> wrote in message news:7d0c7212-b328-438c-a377-10539a205877@googlegroups.com... El miércoles, 18 de diciembre de 2013 23:07:27 UTC-6, Craig Dawson escribió: > Hi all. I've been trying to communicate with a PSC Magellan 8100 Omega POS > > Scale/Barcode Scanner using Ginny's serial class but am having little > > success. > > Does anyone have any sample code that might help me out? > > Regards, Craig. Hi Craig: I used the free OPOS library to do that. http://monroecs.com/oposccos_current.htm Maybe you serve... Regards, Jesus.
[toc] | [prev] | [next] | [standalone]
| From | "Gerhard Bunzel" <g.bunzel@domonet.de> |
|---|---|
| Date | 2013-12-20 00:07 +0100 |
| Message-ID | <l8vu77$ibc$1@news.m-online.net> |
| In reply to | #6428 |
Craig, - Do you use that scanner with the serial interface kit? This scanner is also available with communication to IBM 46XX, RS-232, or IBM USB - Is the configuration of this scanner as RS-232? You can do this by reading some setup-barcodes. We do a lot with serial communication to barcode scanners, scales, printers and mobile data capturing and use Ginny's class without problems. Regards Gerhard Bunzel "Craig Dawson" <craig_dawson@hotmail.com> schrieb im Newsbeitrag news:l8tuuh$hjv$1@dont-email.me... > Hi all. I've been trying to communicate with a PSC Magellan 8100 Omega POS > Scale/Barcode Scanner using Ginny's serial class but am having little > success. > Does anyone have any sample code that might help me out? > Regards, Craig. >
[toc] | [prev] | [next] | [standalone]
| From | "Craig Dawson" <craig_dawson@hotmail.com> |
|---|---|
| Date | 2013-12-20 12:47 +1100 |
| Message-ID | <l907j7$ane$1@dont-email.me> |
| In reply to | #6434 |
Hi Gerhard, thanks for your reply. It is a serial RS-232 single cable connection and I have done a factory reset on it. so the protocol should now be 9600, Odd, 7, 1 Yes I use Ginny's classes for pole displays and other scales and they work great, but this machine looks like I need to constantly poll for activity (for when something is scanned), but then turn off polling when something is to be weighed - then request the weight and turn polling back on. Does that sound familiar to how you have gone about things? Appreciate your input. Regards, Craig. "Gerhard Bunzel" <g.bunzel@domonet.de> wrote in message news:l8vu77$ibc$1@news.m-online.net... > Craig, > > - Do you use that scanner with the serial interface kit? This scanner is > also available with communication to IBM 46XX, RS-232, or IBM USB > - Is the configuration of this scanner as RS-232? You can do this by > reading some setup-barcodes. > > We do a lot with serial communication to barcode scanners, scales, > printers and mobile data capturing and use Ginny's class without problems. > > Regards > > Gerhard Bunzel > > > "Craig Dawson" <craig_dawson@hotmail.com> schrieb im Newsbeitrag > news:l8tuuh$hjv$1@dont-email.me... >> Hi all. I've been trying to communicate with a PSC Magellan 8100 Omega >> POS Scale/Barcode Scanner using Ginny's serial class but am having little >> success. >> Does anyone have any sample code that might help me out? >> Regards, Craig. >> > >
[toc] | [prev] | [next] | [standalone]
| From | "Gerhard Bunzel" <g.bunzel@domonet.de> |
|---|---|
| Date | 2013-12-20 11:02 +0100 |
| Message-ID | <l914j2$f8s$1@news.m-online.net> |
| In reply to | #6436 |
Hi Craig, we do polling also on some scales. Polling will be started with a command and sends data every second. Polling will be stoped also with a command to the scale. I think your scale/scanner is waiting, that your RS-232 port is ready to receive - therefor you have to play with RTS (Request To Send) and CTS (Clear To Send) or DTR (Data Terminal Ready) and DSR (Data Set Ready) on your serial port. Please try to set CTS to show the scale, your programm is ready to receive (Clear To Send - Indicates DCE is ready to accept data.) From wikipadia - this is better reading than my bad english: In older versions of the specification, RS-232's use of the RTS and CTS lines is asymmetric: The DTE asserts RTS to indicate a desire to transmit to the DCE, and the DCE asserts CTS in response to grant permission. This allows for half-duplex modems that disable their transmitters when not required, and must transmit a synchronization preamble to the receiver when they are re-enabled. HTH Gerhard "Craig Dawson" <craig_dawson@hotmail.com> schrieb im Newsbeitrag news:l907j7$ane$1@dont-email.me... > Hi Gerhard, thanks for your reply. > It is a serial RS-232 single cable connection and I have done a factory > reset on it. so the protocol should now be 9600, Odd, 7, 1 > Yes I use Ginny's classes for pole displays and other scales and they work > great, but this machine looks like I need to constantly poll for activity > (for when something is scanned), but then turn off polling when something > is to be weighed - then request the weight and turn polling back on. > Does that sound familiar to how you have gone about things? Appreciate > your input. > Regards, Craig. > > > "Gerhard Bunzel" <g.bunzel@domonet.de> wrote in message > news:l8vu77$ibc$1@news.m-online.net... >> Craig, >> >> - Do you use that scanner with the serial interface kit? This scanner is >> also available with communication to IBM 46XX, RS-232, or IBM USB >> - Is the configuration of this scanner as RS-232? You can do this by >> reading some setup-barcodes. >> >> We do a lot with serial communication to barcode scanners, scales, >> printers and mobile data capturing and use Ginny's class without >> problems. >> >> Regards >> >> Gerhard Bunzel >> >> >> "Craig Dawson" <craig_dawson@hotmail.com> schrieb im Newsbeitrag >> news:l8tuuh$hjv$1@dont-email.me... >>> Hi all. I've been trying to communicate with a PSC Magellan 8100 Omega >>> POS Scale/Barcode Scanner using Ginny's serial class but am having >>> little success. >>> Does anyone have any sample code that might help me out? >>> Regards, Craig. >>> >> >> > >