Il 31/03/2021 10:23, David Brown ha scritto: > On 31/03/2021 00:34, pozz wrote: >> Il 28/03/2021 00:37, pozz ha scritto: >>> Il 26/03/2021 16:54, antispam@math.uni.wroc.pl ha scritto: >>>> pozz <pozzugno@gmail.com> wrote: >>>>> Are there any *real* implementation of multi-master half-duplex >>>>> RS485 bus? >>>>> >>>>> I often use half-duplex RS485 and I always use a master-slave polling >>>>> protocol. This choice dramatically reduce the complexity of the system >>>>> and it works well with a limited number of nodes. >>>>> >>>>> When the nodes are 10 or 20 and they usually send only a few bytes in a >>>>> minuted, the polling scheme is inefficient. The bus is alway busy for >>>>> polling, but the real data are very small. >>>> >>>> What do you really want? That is what is your "efficiency" >>>> criterion. For embedded system a lot of folks consider >>>> worst case delay. For normal design worst case is when >>>> all nodes have data to transmit. Clearly, "last node" >>>> have to wait on all previous nodes. So, best "efficiency" >>>> would be sum of transmit times for data. On top ot that >>>> you have various overhead: bus turnaround times, time >>>> for polling or token passing, possible timeout in case >>>> of fixed time slots. AFAICS polling messages from master >>>> to slave may be very small, so they should at most >>>> double time: you have twice as many messages compared >>>> to case when each node "magically" knows when to >>>> transmit. You can play some tricks, like group poll, >>>> when nodes are ordered (numbered) and each node in >>>> the group is supposed to send its data, starting from >>>> first. Of course, it means that each node must be >>>> capable of detecting end of transmission from >>>> lower numbered node. Token passing may be slightly >>>> more efficient, as data messages may serve double >>>> duty of passing token to next node: so you save >>>> cost of polling messages. >>>> >>>> But you basically fight with constant factor of 2. >>>> If you need more improvement, then you need bigger >>>> change. Say faster links or star topology. In >>>> star topology intermediate nodes may aggregate >>>> messages, so you can significantly decrease number >>>> of messages going to maser node. And it is easier >>>> to provide fast links to limited number of "hub" >>>> nodes, than to have fast links everywhere. But >>>> as downside, there is more complexity and potentially >>>> lower reliability... >>>> >>> >>> Suppose you have a bus with 20-30 nodes: one master is the central >>> unit, the other are slaves that get a code from a keypad. When a code >>> is typed on the keypad, it is transmitted to the master. If it is ok, >>> master sends an ack to the slave that get the code so it enabled an >>> electric lock and the door is unlocked. >>> >>> With a polling scheme, master must sends a poll request continuously >>> and the the slaves answer, most of the time, with no data. It appears >>> to me a very inefficient approach. >>> >>> What's the worst case, i.e. the delay between pressing OK button on >>> the keypad and the door opening? It is the sum of 30 (number of >>> slaves) polling requests and replies. If a single request takes 100ms, >>> the worst case should be around 3 seconds. >>> I'd like to reduce this time to 100ms. >>> >>> It is impossible with polling approach. However the bus is idle >>> (without real data) most of the time. I could avoid polling at all and >>> instruct the slave to transmit when it wants. I think the probability >>> of a conflict with another slave is very low and I could reach the >>> requirement of 100ms above. However I sholud design the behaviour with >>> a conflict, even rare, happens. >> >> Many thanks to all of you that spent some time to answer my question. >> >> Some additional details. The example I wrote is... just an example and >> not exactly the real application. The system has a central unit and many >> slaves installed in different places of a building (imagine a keypad, a >> sensor and so on). This is a home/building automation application. >> >> After first connection the master sends many configuration data to >> slaves (around 2-4kB), so CAN bus is not ideal because of its small >> packets (however I can split data on different packets). >> Then the bus stays idle for most of the time. The user could interact >> with a slave and only in that case the slave has something to tell to >> the master. > > CAN is a short-range protocol. If your bus is over about 20-30 m, > forget CAN. (People do use it for longer distances, at low speeds, but > it's horrible for the task. And CANOpen and other "standards" look like > they were designed specifically to be as complex and inefficient as > possible.) For a short range, small message bus on a closed network > entirely under your control, CAN is great. > >> >> Yes, you are right when you say that putting a known limit on the worst >> case can be done with a polling approach. However my goal is not limit >> the worst case, but minimizing the "normal"/mean delay in the >> slave->master->slave transaction. >> I know this mean of delays can be reduced a lot, because the bus is idle >> most of the time, so the probability of a conflict is very very low. >> >> Even number of slaves was just an example. I can think of systems with >> 50 or 100 slaves and in those cases the polling approach performance >> would be very bad. >> > > You should try to think about having multiple bus segments with fewer > nodes per segment, and some sort of aggregator or gateway that combines > them. > >> Do you know of real wired cable used in home/building automation? I >> heard about KNX on twisted pair, but I think the complexity and cost of >> the system would increase very fast. >> > > I think KNX is mainly used in lifts, but I'm not sure. There are a > large number of "standards" used for building automation, with a variety > of pros and cons, standardisation processes, membership fees, > complexities, etc. > > As Don said, often the cost of the wiring is the real price. But that > can depend on where you are (the ratio of electrician hourly rate to > cable price per meter varies hugely around the world) and the stage the > building is at. Pulling one more cable while the building is being > constructed, is practically free. Installing hidden wiring in a > building in heavy use is massively expensive. > > So sometimes using existing Ethernet networks, wireless networks (either > Wifi or a dedicated wireless network), or even power-line communication > can be cheaper than wiring. > > If you want the newest and coolest solution, try two-wire Ethernet. > Long-range does 2 km point to point, while short range is (IIRC) 40 m on > a multi-drop bus - though I haven't seen any PHYs for short range > two-wire Ethernet as yet. > Do you mean 10BASE-T1L and 10BASE-T1S? Actually my RS485 bus is wired without great care in normal condition: star, bus, tree or mixed topology. Does T1L support only point-to-point, i.e. star topology? Is the center of the star a switch/hub with N ports? T1S could be great because of multi-drop, but 40m can be limiting.
Back to comp.arch.embedded | Previous | Next — Previous in thread | Next in thread | Find similar | Unroll thread
Multi-master RS485 pozz <pozzugno@gmail.com> - 2021-03-25 17:27 +0100
Re: Multi-master RS485 Don Y <blockedofcourse@foo.invalid> - 2021-03-25 09:33 -0700
Re: Multi-master RS485 Grant Edwards <invalid@invalid.invalid> - 2021-03-25 16:38 +0000
Re: Multi-master RS485 Don Y <blockedofcourse@foo.invalid> - 2021-03-25 09:57 -0700
Re: Multi-master RS485 David Brown <david.brown@hesbynett.no> - 2021-03-25 20:28 +0100
Re: Multi-master RS485 pozz <pozzugno@gmail.com> - 2021-03-25 17:57 +0100
Re: Multi-master RS485 Don Y <blockedofcourse@foo.invalid> - 2021-03-25 10:04 -0700
Re: Multi-master RS485 upsidedown@downunder.com - 2021-03-25 19:02 +0200
Re: Multi-master RS485 antispam@math.uni.wroc.pl - 2021-03-26 15:54 +0000
Re: Multi-master RS485 pozz <pozzugno@gmail.com> - 2021-03-28 00:37 +0100
Re: Multi-master RS485 Richard Damon <Richard@Damon-Family.org> - 2021-03-27 20:14 -0400
Re: Multi-master RS485 upsidedown@downunder.com - 2021-03-28 07:32 +0300
Re: Multi-master RS485 Richard Damon <Richard@Damon-Family.org> - 2021-03-28 07:20 -0400
Re: Multi-master RS485 upsidedown@downunder.com - 2021-03-28 14:59 +0300
Re: Multi-master RS485 Richard Damon <Richard@Damon-Family.org> - 2021-03-28 08:09 -0400
Re: Multi-master RS485 antispam@math.uni.wroc.pl - 2021-03-28 02:01 +0000
Re: Multi-master RS485 Don Y <blockedofcourse@foo.invalid> - 2021-03-27 19:57 -0700
Re: Multi-master RS485 Hans-Bernhard Bröker <HBBroeker@t-online.de> - 2021-03-28 15:52 +0200
Re: Multi-master RS485 Richard Damon <Richard@Damon-Family.org> - 2021-03-28 13:06 -0400
Re: Multi-master RS485 pozz <pozzugno@gmail.com> - 2021-03-31 00:34 +0200
Re: Multi-master RS485 Don Y <blockedofcourse@foo.invalid> - 2021-03-30 18:51 -0700
Re: Multi-master RS485 upsidedown@downunder.com - 2021-03-31 06:42 +0300
Re: Multi-master RS485 Stef <stef33d@yahooI-N-V-A-L-I-D.com.invalid> - 2021-03-31 09:50 +0200
Re: Multi-master RS485 David Brown <david.brown@hesbynett.no> - 2021-03-31 10:23 +0200
Re: Multi-master RS485 pozz <pozzugno@gmail.com> - 2021-03-31 12:27 +0200
Re: Multi-master RS485 David Brown <david.brown@hesbynett.no> - 2021-03-31 14:43 +0200
Re: Multi-master RS485 pozz <pozzugno@gmail.com> - 2021-03-31 13:39 +0200
Re: Multi-master RS485 David Brown <david.brown@hesbynett.no> - 2021-03-31 14:46 +0200
Re: Multi-master RS485 Don Y <blockedofcourse@foo.invalid> - 2021-03-31 06:20 -0700
Re: Multi-master RS485 upsidedown@downunder.com - 2021-03-31 15:29 +0300
Re: Multi-master RS485 David Brown <david.brown@hesbynett.no> - 2021-03-31 14:49 +0200
csiph-web