On 07/01/2022 22:39, Rolf Bombach wrote: > Helmut Schellong schrieb: >>> >>> Beispiel 100 nF-Kondensator >>> >>> R&S HM 8118 LCR-Meter 0.05 %: >>> ---------------------- >>> C=100.76 nF f=10 kHz >>> ESR=4.5 mOhm f=10 kHz >>> >>> C=100.76 nF f=1 kHz >>> ESR=190 mOhm f=1 kHz >>> Z=1.5794 kOhm >>> >>> Sourcetronic ST2822D LCR-Meter 0.1 %: >>> ------------------------------- >>> C=100.76 nF f=10 kHz >>> ESR=4.6 mOhm f=10 kHz >>> >>> C=100.76 nF f=1 kHz >>> ESR=490 mOhm f=1 kHz >>> Z=1.5793 kOhm >> >> Zumindest auf den ersten Blick ist mir unerklärlich, wie Z >> praktisch identisch sein kann bei derartig unterschiedlichen ESR!? > > Bei 1 kHz hat ein idealer 100.76 nF C schon 1.5795 kOhm X. > Da noch irgendwie einen ESR rauszuleiern, womöglich mit akzeptabler > Genauigkeit, scheint mir technisch nicht möglich. Die Testfrequenz > ist einfach zu tief. Mich wundert es eher, dass da nicht totale > Hausnummern rauskommen. > Bei 10 kHz wurden ja 4.5:4.6 mOhm ESR gemessen und bei 1 kHz 190:490 mOhm. Ja, das deutet auf eine zu geringe f=1kHz hin. Der Xc ist bei 1000 Hz im Vergleich zum ESR zu groß, um ein genaues Ergebnis erhalten zu können. Die gewöhnlichen Arbeitsfrequenzen für 100 nF liegen ja auch im MHz-Bereich, mindestens bei einigen 100 kHz. 1 kHz ist viel eher eine Elko-Meßfrequenz. -- Mit freundlichen Grüßen Helmut Schellong var@schellong.biz http://www.schellong.de/c.htm http://www.schellong.de/c2x.htm http://www.schellong.de/c_padding_bits.htm http://www.schellong.de/htm/bishmnk.htm http://www.schellong.de/htm/rpar.bish.html http://www.schellong.de/htm/sieger.bish.html http://www.schellong.de/htm/audio_proj.htm http://www.schellong.de/htm/audio_unsinn.htm http://www.schellong.de/htm/tuner.htm http://www.schellong.de/htm/string.htm http://www.schellong.de/htm/string.c.html http://www.schellong.de/htm/deutsche_bahn.htm http://www.schellong.de/htm/schaltungen.htm http://www.schellong.de/htm/rand.htm http://www.schellong.de/htm/dragon.c.html
Back to de.sci.electronics | Previous | Next — Previous in thread | Next in thread | Find similar | Unroll thread
Sourcetronic 0.1% LCR-Meter Leo Baumann <ib@leobaumann.de> - 2022-07-01 16:37 +0200
Re: Sourcetronic 0.1% LCR-Meter Leo Baumann <ib@leobaumann.de> - 2022-07-01 19:37 +0200
Re: Sourcetronic 0.1% LCR-Meter Leo Baumann <ib@leobaumann.de> - 2022-07-01 19:40 +0200
Re: Sourcetronic 0.1% LCR-Meter Helmut Schellong <rip@schellong.biz> - 2022-07-01 20:18 +0200
Re: Sourcetronic 0.1% LCR-Meter Leo Baumann <ib@leobaumann.de> - 2022-07-01 20:43 +0200
Re: Sourcetronic 0.1% LCR-Meter Helmut Schellong <rip@schellong.biz> - 2022-07-01 21:46 +0200
Re: Sourcetronic 0.1% LCR-Meter Leo Baumann <ib@leobaumann.de> - 2022-07-01 22:07 +0200
Re: Sourcetronic 0.1% LCR-Meter onlinefloh <usenet@teply.info> - 2022-07-01 21:07 +0200
Re: Sourcetronic 0.1% LCR-Meter Rolf Bombach <rolfnospambombach@invalid.invalid> - 2022-07-01 22:39 +0200
Re: Sourcetronic 0.1% LCR-Meter Helmut Schellong <rip@schellong.biz> - 2022-07-02 11:53 +0200
Re: Sourcetronic 0.1% LCR-Meter Leo Baumann <ib@leobaumann.de> - 2022-07-02 12:39 +0200
Re: Sourcetronic 0.1% LCR-Meter Leo Baumann <ib@leobaumann.de> - 2022-07-01 23:28 +0200
Re: Sourcetronic 0.1% LCR-Meter Rolf Bombach <rolfnospambombach@invalid.invalid> - 2022-07-02 19:12 +0200
Re: Sourcetronic 0.1% LCR-Meter Leo Baumann <ib@leobaumann.de> - 2022-07-02 19:58 +0200
Re: Sourcetronic 0.1% LCR-Meter Andreas Oehler <andreas.oehler@gmx.de> - 2022-07-03 23:48 +0200
Re: Sourcetronic 0.1% LCR-Meter Leo Baumann <ib@leobaumann.de> - 2022-07-04 00:15 +0200
csiph-web