Groups | Search | Server Info | Login | Register


Groups > comp.sys.acorn.hardware > #7593

Re: RPi 3B+ 5 volt lines

Path csiph.com!news.swapon.de!eternal-september.org!feeder3.eternal-september.org!news.eternal-september.org!.POSTED!not-for-mail
From David Higton <dave@davehigton.me.uk>
Newsgroups comp.sys.acorn.hardware
Subject Re: RPi 3B+ 5 volt lines
Date Sun, 14 Apr 2024 22:35:41 +0100
Organization Home
Lines 22
Message-ID <9a2ba7515b.DaveMeUK@BeagleBoard-xM> (permalink)
References <2c6218505b.DaveMeUK@BeagleBoard-xM> <KLy*96JHz@news.chiark.greenend.org.uk> <68be98505b.DaveMeUK@BeagleBoard-xM> <NLy*uFPHz@news.chiark.greenend.org.uk> <83030e515b.DaveMeUK@BeagleBoard-xM>
Injection-Date Sun, 14 Apr 2024 23:36:33 +0200 (CEST)
Injection-Info dont-email.me; posting-host="2ce54a5197cc712fa03a4dbc03661c07"; logging-data="4046157"; mail-complaints-to="abuse@eternal-september.org"; posting-account="U2FsdGVkX1+vCyczx0znwn4OIiMvXeAo+oauSwjIgQc="
User-Agent Messenger-Pro/8.03 (MsgServe/8.01) (RISC-OS/5.29) NewsHound/v1.54
Cancel-Lock sha1:WhxGRnV9fygWtuCrBheITEs/pqk=
Xref csiph.com comp.sys.acorn.hardware:7593

Show key headers only | View raw


In message <83030e515b.DaveMeUK@BeagleBoard-xM>
          David Higton <dave@davehigton.me.uk> wrote:

> I've just tried 9000uF (9 1000 uF capacitors in parallel) this afternoon.
> I didn't see a restart in the logs when Clonezilla did a backup to OMV,
> but the backup failed anyway, and now I don't know why.

After a lot of experiments, I discovered that recent OpenMediaVault
versions have a bug that causes it to think the NAS becomes unavailable
suddenly, part way through a backup.  I've reverted to a much earlier
version as a result of some web searching.  Note that the OMV bug does
not appear to be repeatable but has been reported by several users.

I was able to get a full backup, but I'm not out of the woods yet.

I also saw OMV restart once anyway during a backup, so, although the
9000uF made things better (failed less often), the problem is still
there.

Double fault situation.

David

Back to comp.sys.acorn.hardware | Previous | NextPrevious in thread | Find similar


Thread

RPi 3B+ 5 volt lines David Higton <dave@davehigton.me.uk> - 2024-04-11 21:59 +0100
  Re: RPi 3B+ 5 volt lines Theo <theom+news@chiark.greenend.org.uk> - 2024-04-12 10:12 +0100
    Re: RPi 3B+ 5 volt lines David Higton <dave@davehigton.me.uk> - 2024-04-12 21:21 +0100
      Re: RPi 3B+ 5 volt lines Theo <theom+news@chiark.greenend.org.uk> - 2024-04-13 11:32 +0100
        Re: RPi 3B+ 5 volt lines David Higton <dave@davehigton.me.uk> - 2024-04-13 18:42 +0100
          Re: RPi 3B+ 5 volt lines David Higton <dave@davehigton.me.uk> - 2024-04-14 22:35 +0100

csiph-web